Orange County NC Website
DocuSign Envelope ID: 9ADC47E5- lDA5- 49A9- ADC8- 76352A593CBF <br />1:a7 <br />O <br />I <br />II <br />is <br />\ N <br />to <br />U ■ <br />2 ■ <br />■ <br />0 ■O <br />11 <br />E <br />F <br />G <br />H <br />These instructions comply with Underwriters Laboratories <br />Safety Standard 555. UL File No. R5531. <br />X L SEE DETAILS ON <br />UL CLASSIFICATION <br />MARKING ON ENCLOSED <br />PRODUCT <br />Note: California State Fire Marshal Listing No. 3225 - 245:004 <br />Dimensions shown in parentheses { ) indicate millimeters. (Vertical and Horizontal mounting) <br />11-1131323-1094(R)/Replaces II -I13023 -692 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. ©Ruskin Manufacturing 1995 <br />System No. CAJ 1 001 <br />(Formerly System No. 49) <br />F Rating -3 Hr <br />T Rating -0 Hr <br />f-1-A <br />4 1 5 <br />1. Expansion Clearance <br />1 <br />2 <br />3 <br />assemblies. The opening in the wall or floor must be a minimum <br />Rectangular ducts must use one or more of the connections <br />of 1 /e" per foot (3 per 305) larger than the overall damper /sleeve <br />a <br />assembly size for galvanized steel dampers and a minimum 3/16" <br />A <br />RUSKINO <br />Mullion Req'd. <br />opening size is 2" (51) larger than the minimum clearance <br />=� I <br />dimensions above. Example: Opening for a 36" x 24" <br />damper /sleeve assembly can be 363/®" x 241/4" minimum up to <br />, <br />\ ao <br />3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761 -7476 0 FAX (816) 765 -8955 <br />_ <br />larger than the damper /sleeve assembly. <br />IINSTALLATION INSTRUCTIONS <br />STANDING S STANDING 5 STANDING S (ALT.) STANDING S <br />3 HOUR UL CLASSIFIED <br />(Angle Reinforced) (Bar Reinforced) <br />Use No. 10 (M5) bolts or screws, 3/1.6" (5) rivets, tack welds or <br />CURTAIN TYPE FIRE DAMPERS <br />spot welds as depicted in figures 2 and 4 and spaced as follows <br />-J <br />I MODEL (D)IBD23 <br />damper assemblies or when fastening damper to the sleeve: <br />STANDING S DRIVE SLIP JOINT <br />Vertical Mount (In wall) <br />(Angle Reinforced) <br />APPLICATION INSTALLATION SUPPLEMENTS <br />IN <br />A maximum of two #10 sheet metal screws on each side and the <br />Horizontal Mount (In floor) <br />The (D)IBD23 carries a 3 hour fire damper label and is approved Refer to the appropriate Ruskin installation operation instructions <br />All dampers 6" (152) spacing <br />both sides of the slip pocket may be used. Connections using <br />r <br />r F Z <br />for use in fire walls or floors with ratings of 3 hours or more. Fire supplements for special requirements: <br />Multiple section dampers require a 14 gage thick x 41/2" (2 x 114) <br />20" (508) long on the sides may also be used. <br />Dampers require a field- or factory- installed sleeve. Select a sleeve - S- and- Drivemate No. 14880 <br />Round and Oval Break -away Connections <br />with 1/2" (13) long welds staggered intermittently and spaced on <br />of sufficient length to permit attachment, with perimeter mounting - Ductmate <br />I <br />maximum 6" (152) centers. The mullion plate must be the same <br />4" (102) wide drawband or #10 sheet metal screws spaced <br />angles, to duct work on each side of wall or floor opening. <br />equally around the circumference of the duct as follows: <br />the damper width of two or more adjoining damper sections. <br />o - Sealing of Dampers in Fire Rated Walls or Floors <br />Mullions are not required for assemblies consisting of two <br />dampers attached end -to -end or three dampers attached side -to- <br />-Duct diameters over 22" (559) and including 36" (914) - Maxi - <br />IBD23 MAXIMUM SIZE <br />mum 5 screws. <br />° Duct diameters over 36" (914) and up to and including 191" <br />3. Damper Sleeve <br />(sizes apply to galvanized and stainless steel construction) <br />the diameter is considered the largest (major) dimension of the <br />Single Section <br />duct. <br />10 gage (3.5) steel. Sleeve thickness must be equal to or thicker <br />Vertical Installation - 36 "w x 36 "h (914 x 914). <br />than the duct connected to it. Sleeve gage requirements are list- <br />lowing sealants may be applied in accordance with the sealant <br />Horizontal Installation - 30 "w x 451/2 "h (762 x 1156). <br />manufacturer's instructions: <br />Installation Guide For HVAC Systems and in NFPA90A. If a <br />Multiple Section Assembly <br />break -away style duct /sleeve connection is not used, sleeve <br />precision - PA2084T <br />Vertical Installation - 90 "w x 72 "h (2286 x 1829). <br />24" height and 14 gage (2) minimum when damper exceeds 36" <br />wide or 24" high. Sleeve must be fastened to damper as <br />Horizontal Installation - 90 "w x 91 "h (2286 x 2301). <br />described in (note 2). Sleeve must not extend more than 6" (152) <br />B <br />out of the wall or floor. Exception - Dampers equipped with fac- <br />or Ward are approved break -away connections when installed as <br />tory installed access door may extend 16" (406) out of the wall or <br />DIBD23 MAXIMUM SIZE <br />floor on the access door side. Sleeves must terminate on both <br />6 <br />(sizes apply to galvanized and stainless steel construction) <br />and 3. <br />Single Section <br />4. Damper Orientation <br />6" (152 ) Long <br />Ductmate 1h6" (1.6) Max. Thk. <br />Vertical or Horizontal Installation - 33 "w x 36 "h (838 x 914). <br />An le Plastic Cleat <br />12" (305) c -c <br />SHEET TITLE: <br />C Multiple Section Assembly <br />® <br />(Min. 1 per side) <br />CONSTRUCTION <br />Vertical Installation - 90 "w x 72 "h (2286 x 1829). <br />DJM <br />With Arrow Up" labels on Dynamic DIED and DIBDX models for <br />:- Horizontal Installation - 90 "w x 91 "h (2286 x 2301). <br />MRM <br />PROJECT #: <br />s II <br />\ a <br />proper damper orientation. For Static IBD models use only <br />DATE: <br />05/24/2018 <br />"Mount With Arrow Up" label on damper for proper damper ori- <br />U <br />entation. <br />5. Mountinq Anqles <br />�m <br />- <br />C9 1 m <br />1� <br />'N <br />'O <br />1:a7 <br />O <br />I <br />II <br />is <br />\ N <br />to <br />U ■ <br />2 ■ <br />■ <br />0 ■O <br />11 <br />E <br />F <br />G <br />H <br />These instructions comply with Underwriters Laboratories <br />Safety Standard 555. UL File No. R5531. <br />X L SEE DETAILS ON <br />UL CLASSIFICATION <br />MARKING ON ENCLOSED <br />PRODUCT <br />Note: California State Fire Marshal Listing No. 3225 - 245:004 <br />Dimensions shown in parentheses { ) indicate millimeters. (Vertical and Horizontal mounting) <br />11-1131323-1094(R)/Replaces II -I13023 -692 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. ©Ruskin Manufacturing 1995 <br />System No. CAJ 1 001 <br />(Formerly System No. 49) <br />F Rating -3 Hr <br />T Rating -0 Hr <br />f-1-A <br />4 1 5 <br />1. Expansion Clearance <br />6. Duct/Sleeve Connections <br />Expansion clearance is required for all fire damper /sleeve <br />Breakaway Duet/Sleeve Connections <br />assemblies. The opening in the wall or floor must be a minimum <br />Rectangular ducts must use one or more of the connections <br />of 1 /e" per foot (3 per 305) larger than the overall damper /sleeve <br />depicted below: <br />assembly size for galvanized steel dampers and a minimum 3/16" <br />See Note 3 <br />per foot (5 per 305) for stainless steel dampers. The maximum <br />Mullion Req'd. <br />opening size is 2" (51) larger than the minimum clearance <br />PLAIN "S" SLIP HEMMED "S" SLIP DOUBLE "S" SLIP INSIDE SLIP JOINT <br />dimensions above. Example: Opening for a 36" x 24" <br />damper /sleeve assembly can be 363/®" x 241/4" minimum up to <br />, <br />3831x" x 261/4" maximum. All openings must be at least 1/4" (6) <br />_ <br />larger than the damper /sleeve assembly. <br />STANDING S STANDING 5 STANDING S (ALT.) STANDING S <br />2. Fasteners and Multiple Section Assembly <br />(Angle Reinforced) (Bar Reinforced) <br />Use No. 10 (M5) bolts or screws, 3/1.6" (5) rivets, tack welds or <br />�•' J °aO° LVC- '� ° °� °�y4 <br />spot welds as depicted in figures 2 and 4 and spaced as follows <br />-J <br />when joining individual dampers to make multiple section <br />damper assemblies or when fastening damper to the sleeve: <br />STANDING S DRIVE SLIP JOINT <br />Vertical Mount (In wall) <br />(Angle Reinforced) <br />All dampers 6" (152) spacing <br />A maximum of two #10 sheet metal screws on each side and the <br />Horizontal Mount (In floor) <br />bottom, located in the center of the slip pocket and penetrating <br />All dampers 6" (152) spacing <br />both sides of the slip pocket may be used. Connections using <br />r <br />r F Z <br />these slip joints on the top and bottom with flat drive slips up to <br />Multiple section dampers require a 14 gage thick x 41/2" (2 x 114) <br />20" (508) long on the sides may also be used. <br />wide steel mullion plate sandwiched between the damper frames <br />Round and Oval Break -away Connections <br />with 1/2" (13) long welds staggered intermittently and spaced on <br />Round and flat oval break -away connections must use either a <br />maximum 6" (152) centers. The mullion plate must be the same <br />4" (102) wide drawband or #10 sheet metal screws spaced <br />material as the dampers. The mullion length must be equal to <br />equally around the circumference of the duct as follows: <br />the damper width of two or more adjoining damper sections. <br />- Duct diameters 22" (559) and smaller - Maximum 3 screws. <br />Mullions are not required for assemblies consisting of two <br />dampers attached end -to -end or three dampers attached side -to- <br />-Duct diameters over 22" (559) and including 36" (914) - Maxi - <br />side as depicted in figure 5. <br />mum 5 screws. <br />° Duct diameters over 36" (914) and up to and including 191" <br />3. Damper Sleeve <br />(4851) total perimeter- Maximum 8 screws. For flat oval ducts, <br />the diameter is considered the largest (major) dimension of the <br />Damper sleeve must be minimum 26 gage (.6) up to a maximum <br />duct. <br />10 gage (3.5) steel. Sleeve thickness must be equal to or thicker <br />Note: When optional sealing of these joints is desired, the fol- <br />than the duct connected to it. Sleeve gage requirements are list- <br />lowing sealants may be applied in accordance with the sealant <br />ed in the SMACNA Fire, Smoke and Radiation Damper <br />manufacturer's instructions: <br />Installation Guide For HVAC Systems and in NFPA90A. If a <br />Hardcast, Inc- - Iron Grip 601 <br />break -away style duct /sleeve connection is not used, sleeve <br />precision - PA2084T <br />must be 16 gage (1.6) minimum for dampers up to 36" wide or <br />24" height and 14 gage (2) minimum when damper exceeds 36" <br />wide or 24" high. Sleeve must be fastened to damper as <br />Flanged Break -away Style Duct Sleeve Connections. <br />described in (note 2). Sleeve must not extend more than 6" (152) <br />Flanged connection systems manufactured by Ductmate, Nexus <br />out of the wall or floor. Exception - Dampers equipped with fac- <br />or Ward are approved break -away connections when installed as <br />tory installed access door may extend 16" (406) out of the wall or <br />depicted. <br />floor on the access door side. Sleeves must terminate on both <br />6 <br />sides of the wall or floor within the dimension shown in figures 1 <br />and 3. <br />° <br />4. Damper Orientation <br />6" (152 ) Long <br />Ductmate 1h6" (1.6) Max. Thk. <br />Damper must be installed with the blades within the wall or floor <br />An le Plastic Cleat <br />12" (305) c -c <br />SHEET TITLE: <br />when they are in the closed position. Use "Air Flow" and "Mount <br />® <br />(Min. 1 per side) <br />CONSTRUCTION <br />DRAWN BY: <br />DJM <br />With Arrow Up" labels on Dynamic DIED and DIBDX models for <br />m <br />MRM <br />PROJECT #: <br />2018034 <br />proper damper orientation. For Static IBD models use only <br />DATE: <br />05/24/2018 <br />"Mount With Arrow Up" label on damper for proper damper ori- <br />entation. <br />5. Mountinq Anqles <br />- <br />(38 x 38 x 1.6) conventional mounting angles fastened to the <br />damper sleeve with No. 10 (M5) bolts or screws, 3/16" (5) rivets, <br />tack welds or spot welds as depicted in figures 1 and 3, spaced <br />a maximum of 6" (152) on center. <br />Larger dampers require minimum 11/2" x 1112' x 14 gage (38 x 38 <br />x 2) conventional mounting angles fastened to damper sleeve <br />with No. 10 (M5) bolts or screws, 3h6" (5) rivets, tack welds or <br />spot welds as depicted in figures 1 and 3 and spaced as follows: <br />Galvanized steel dampers 6" (152) spacing <br />Stainless steel dampers 6" (152) spacing <br />Mounting angles must overlap the wall or floor a minimum of 1" <br />(25). Do not fasten angles together at corners of the <br />damper /sleeve assembly. <br />1. Floor or Wall Assembly -Min 4 -1/2 in. thick lightweight or normal weight (1D0-150 pcf) con- <br />crete. Wall may also be constructed of any UL Classified Concrete Blocks *. Max diam of cir- <br />cular through opening is 22 -1/2 in. <br />See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manu- <br />facturers. <br />1A. Steel Sleeve - (Optional, not shown)--Nom 12 in. diem (or smaller) Schedule 40 (or heavier) <br />steel pipe sleeve cast into concrete floor or wall. Sleeve to be flush with or project max 2 in. <br />from top surface of floor or from both surfaces of wall. <br />2. Pipe or Conduit-Nom 20 in. diam (or smaller) Schedule 10 (or heavier) steel pipe, nom S in. <br />diam (or smaller) rigid steel conduit or Type L (or heavier) copper tube, nom 4 in. diam for <br />smaller) cast iron pipe or steel EMT. Max one pipe or conduit per through opening. Max annu- <br />lar space between pipe or conduit and edge of through opening not to exceed 2 -1/2 in. Min <br />annular space between pipe or conduit and edge of through opening is zero in. (point con- <br />tact). Pipe or conduit to be rigidly supported on both sides of floor or wall assembly. <br />3. Packing Material - Polyethylene backer rod or nom 1 in. thickness of tightly- packed ceramic <br />(alumina silica) fiber blanket, mineral -wool batt or glass fiber insulation material used as a per- <br />manent form. Packing material to be recessed from top surface of floor or from both surfaces <br />of wall as required to accommodate the required thickness of caulk fill material (Item 4). As an <br />alternate when max pipe size is 10 in. diam and when max annular space is 1 in., a min 1 in. <br />thickness of tightly- packed ceramic fiber blanket or mineral -wool batt packing material may be <br />recessed min 1/2 in, from bottom surface of floor or from either side of wall. <br />4. Fill, Void or Cavity Materials'- Caulk - Applied to fill the annular space to the min thickness <br />shown in the following table: <br />Max Pipe Max Annular Packing Material Min Caulk <br />Diam In Space In Type (a) Thkne in <br />10 1 BR, CF, GF or MW 1/2 (b) <br />10 1 CF or MW 112 (c) <br />20 2 -1/2 BR, CF, GF or MW 1 (b) <br />(a) BR= Polyethylene backer rod. <br />CF= Ceramic fiber blanket. <br />GF =Glass fiber insulation. <br />MW= Mineral-wool batt. <br />(b) Caulk installed flush with top surface of floor or both surfaces of wall <br />(c) Caulk installed flush with bottom surface of floor or one surface of wall <br />Minnesota Mining & Mfg. Co. Type CP 25N /S <br />Bearing the UL Classification Marking <br />This material was extracted by 3M Firc Protection Products <br />3M Fire Protection Products from the 1996 edition of the UL Fire Resistance Directory. <br />1 1 2 1 3 <br />96 <br />4 <br />o Neoprene <br />Gasket <br />TDC (by Lockformer) and TDF (by Engle) flanged connections <br />are approved break -away connections when installed as <br />described in the TDC or TDF addendum to the SMACNA Duct <br />Construction Standards except the corners may not be bolted. <br />The standard 6" (152) metal clip may be used with spacing as <br />depicted in the addendum. <br />Non - Break -away Duct/Sleeve Connections <br />If other duct sleeve connections are used, the sleeve shall be a <br />minimum of 16 gage (1.6) for dampers up to 36" (914) wide x 24" <br />(610) high and 14 gage (2.0) for dampers exceeding 36" (914) <br />wide x 24" (610) high. <br />A <br />VERTICAL INSTALLATION <br />1" (25) Min. 1/4 "(6) Clearance <br />Overlap (Four Sides) (See Note 1) <br />FIGURE 1�ji tl See Note 5 <br />Masonry f <br />, Wall ee <br />d <br />a <br />s <br />0 <br />U <br />r 6" or 16" <br />(152 or 406) <br />Max. <br />See Note 3 <br />See Note 2 <br />I <br />ENGINEERS <br />Reece, Noland & McElrath, Inc. <br />1/4" (5) Clearance <br />Z <br />L (See Note 1) <br />N <br />°3 <br />See Note 5 <br />See Note 3 <br />® <br />Mullion Req'd. <br />z <br />8 ° <br />- <br />- <br />U <br />Z Q <br />�- <br />Z uJ <br />W <br />U <br />0 <br />Q W w W <br />�•' J °aO° LVC- '� ° °� °�y4 <br />Q <br />-J <br />(j <br />= N =) Z <br />I- Cl- <br />r <br />. CO) <br />r j <br />w <br />LLJ <br />V <br />Z <br />See Note 2 <br />See Note 2 <br />6" (15 "2�I))N <br />2" (51) <br />See Note <br />FIGURE 2 <br />6-(152) <br />A <br />HORIZONTAL INSTALLATION <br />FIGURE 4 <br />System No. CAJ6001 <br />(Formerly System No. 91) <br />F Ratings- 1 -1/2, 2 and 3 Hr (See Item 4) <br />T Ratings --0, 1/2, 3/4 and 1 Hr (See Items 1,4 and 4) <br />L Rating At Ambient -2 CFM per sq ft <br />L Rating At 400 F -less than 1 CFM per sq ft <br />F-1,­A 1 1I <br />Mullion Plate <br />See Note 2 <br />/Y 6. <br />.4" <br />VA <br />1" (25) Min. <br />Overlap (Four Sides) <br />See Note 2 <br />Sleeve (See Note 3) <br />ENGINEERS <br />Reece, Noland & McElrath, Inc. <br />1/4" (5) Clearance <br />6" or 16" <br />L (See Note 1) <br />(152 or 406) Max. <br />See Note 5 <br />See Note 3 <br />See Note 2 <br />6" (15 "2�I))N <br />2" (51) <br />See Note <br />FIGURE 2 <br />6-(152) <br />A <br />HORIZONTAL INSTALLATION <br />FIGURE 4 <br />System No. CAJ6001 <br />(Formerly System No. 91) <br />F Ratings- 1 -1/2, 2 and 3 Hr (See Item 4) <br />T Ratings --0, 1/2, 3/4 and 1 Hr (See Items 1,4 and 4) <br />L Rating At Ambient -2 CFM per sq ft <br />L Rating At 400 F -less than 1 CFM per sq ft <br />F-1,­A 1 1I <br />Mullion Plate <br />See Note 2 <br />/Y 6. <br />.4" <br />VA <br />1" (25) Min. <br />Overlap (Four Sides) <br />See Note 2 <br />L-30-A II <br />SECTION A-A <br />1. Floor or Wall Assembly -Min 2 -1/2 in. thick reinforced lightweight or normal weight (100- <br />150) pcf concrete. Wall may also be constructed of any UL Classified Concrete Blocks`. Max <br />diam of opening is 18 in. <br />See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manu- <br />facturers. <br />1A. Steel Sleeve--(Optional, not shown -Nom 9 in. (or smaller] Schedule 10 (or heavier) steel <br />sleeve cast or grouted into floor or wall assembly. Sleeve may extend a max of 2 in. above <br />top of floor or beyond either surface of wall. Sleeve may be used only when floor or wall as- <br />sembly is min 4 -1/2 in. thick.T Rating is 0 Hr when sleeve is used. <br />2. Through Penetrant -Nom 4 in. diam (or smaller) Type L (or heavier) copper pipe, nom 12 in. <br />diam (or smaller) service weight (or heavier) cast iron soil pipe, nom 12 in. diam (or smaller) <br />Class 50 (or heavier) ductile iron pressure pipe or nom 12 in. diam (or smaller) Schedule 10 <br />(or heavier) steel pipe centered in the opening and rigidly supported on both sides of the floor <br />or wall assembly. <br />3. Pipe Covering * -Nom 1 or 2 in. thick hollow cylindrical heavy density (min. 3.5 pcf) glass fi- <br />ber units jacketed on the outside with an all service jacket. Longitudinal joints sealed with <br />metal fasteners or factory - applied self- sealing lap tape. Transverse joints secured with metal <br />fasteners or with butt strip tape supplied with the product. <br />See Pipe and Equipment Covering - Materials *(BRGU) category in Building Materials Di- <br />rectory for names of manufacturers. Any pipe covering material meeting the above speci& <br />cations and bearing the UL Classification Marking with a Flame Spread Index of 25 or <br />less and a Smoke Developed Index of 50 or less may be used. <br />4. Firestop System -The details of the firestop system shall be as follows: <br />A. Packing Material -Min 1 in, thickness of firmly packed mineral wool batt insulation used <br />as a permanent form. Packing material to be recessed from top surface of floor or sleeve <br />or from both surfaces of wall as required to accommodate the required thickness of caulk <br />fill material (item B). <br />B. Fill, Void or Cavity Material'- Caulk - Applied to fill the annular space flush with the top <br />surface of the floor or sleeve or flush with both surfaces of wall. When nom ,pipe covering <br />thickness is 2 in., min thickness of caulk fill material is 2 in. When nom pipe covering <br />thickness is 1 in., min thickness of caulk fill material is t in. The hourly F and T Ratings of <br />the firestop system are dependent upon the thickness of the floor or wall, the size of pipe, <br />the thickness of pipe covering material and the size of the annular space (between the <br />pipe covering material and the edge of the circular through opening), as shown in the fol- <br />lowing table; <br />Min Floor Or Max Pipe mom Pipe Annular <br />Wall Thkns Diam Covering Thkns Space F Rating T Rating <br />in. In. In. In. Fir Hr <br />2-1/2 4 1 1/2 to 2 -3/8 2 1 <br />4 -1/2 4 2 1/4 to 3 -5/8 2 1 -1/2 <br />2 -1 /2 12 1 1/2 to 1 -1/2 2 1/2 <br />4 -1/2 12 1 1/2 to 2 -3/8 3 1 <br />Minnesota Mining & Mfg. Co. ---CP 25WB +. <br />*Bearing the UL Classification Marking <br />This material was extracted by 3M Fire Protection Products <br />3M Fire Protection Products from the 1996 edition of the UL Fire Resistance Directory. <br />160 <br />5 1 6 <br />7 <br />E <br />f <br />A <br />0 <br />101 <br />u <br />F <br />G <br />H <br />WA <br />RKip <br />ENGINEERS <br />Reece, Noland & McElrath, Inc. <br />1/4" (5) Clearance <br />Canton, North Carolina 28716 <br />L (See Note 1) <br />No Mullion <br />See Note 5 <br />.. Plate Req'd. <br />7�7_, <br />NC CERT. NO. C -0149 <br />Mullion Req'd. <br />No Mullion�v.' <br />Plate Req'd. <br />L-30-A II <br />SECTION A-A <br />1. Floor or Wall Assembly -Min 2 -1/2 in. thick reinforced lightweight or normal weight (100- <br />150) pcf concrete. Wall may also be constructed of any UL Classified Concrete Blocks`. Max <br />diam of opening is 18 in. <br />See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manu- <br />facturers. <br />1A. Steel Sleeve--(Optional, not shown -Nom 9 in. (or smaller] Schedule 10 (or heavier) steel <br />sleeve cast or grouted into floor or wall assembly. Sleeve may extend a max of 2 in. above <br />top of floor or beyond either surface of wall. Sleeve may be used only when floor or wall as- <br />sembly is min 4 -1/2 in. thick.T Rating is 0 Hr when sleeve is used. <br />2. Through Penetrant -Nom 4 in. diam (or smaller) Type L (or heavier) copper pipe, nom 12 in. <br />diam (or smaller) service weight (or heavier) cast iron soil pipe, nom 12 in. diam (or smaller) <br />Class 50 (or heavier) ductile iron pressure pipe or nom 12 in. diam (or smaller) Schedule 10 <br />(or heavier) steel pipe centered in the opening and rigidly supported on both sides of the floor <br />or wall assembly. <br />3. Pipe Covering * -Nom 1 or 2 in. thick hollow cylindrical heavy density (min. 3.5 pcf) glass fi- <br />ber units jacketed on the outside with an all service jacket. Longitudinal joints sealed with <br />metal fasteners or factory - applied self- sealing lap tape. Transverse joints secured with metal <br />fasteners or with butt strip tape supplied with the product. <br />See Pipe and Equipment Covering - Materials *(BRGU) category in Building Materials Di- <br />rectory for names of manufacturers. Any pipe covering material meeting the above speci& <br />cations and bearing the UL Classification Marking with a Flame Spread Index of 25 or <br />less and a Smoke Developed Index of 50 or less may be used. <br />4. Firestop System -The details of the firestop system shall be as follows: <br />A. Packing Material -Min 1 in, thickness of firmly packed mineral wool batt insulation used <br />as a permanent form. Packing material to be recessed from top surface of floor or sleeve <br />or from both surfaces of wall as required to accommodate the required thickness of caulk <br />fill material (item B). <br />B. Fill, Void or Cavity Material'- Caulk - Applied to fill the annular space flush with the top <br />surface of the floor or sleeve or flush with both surfaces of wall. When nom ,pipe covering <br />thickness is 2 in., min thickness of caulk fill material is 2 in. When nom pipe covering <br />thickness is 1 in., min thickness of caulk fill material is t in. The hourly F and T Ratings of <br />the firestop system are dependent upon the thickness of the floor or wall, the size of pipe, <br />the thickness of pipe covering material and the size of the annular space (between the <br />pipe covering material and the edge of the circular through opening), as shown in the fol- <br />lowing table; <br />Min Floor Or Max Pipe mom Pipe Annular <br />Wall Thkns Diam Covering Thkns Space F Rating T Rating <br />in. In. In. In. Fir Hr <br />2-1/2 4 1 1/2 to 2 -3/8 2 1 <br />4 -1/2 4 2 1/4 to 3 -5/8 2 1 -1/2 <br />2 -1 /2 12 1 1/2 to 1 -1/2 2 1/2 <br />4 -1/2 12 1 1/2 to 2 -3/8 3 1 <br />Minnesota Mining & Mfg. Co. ---CP 25WB +. <br />*Bearing the UL Classification Marking <br />This material was extracted by 3M Fire Protection Products <br />3M Fire Protection Products from the 1996 edition of the UL Fire Resistance Directory. <br />160 <br />5 1 6 <br />7 <br />E <br />f <br />A <br />0 <br />101 <br />u <br />F <br />G <br />H <br />WA <br />RKip <br />ENGINEERS <br />Reece, Noland & McElrath, Inc. <br />94 Main Street <br />Canton, North Carolina 28716 <br />PHONE: 828 - 492 -0677 <br />FAX: 828 - 492 -1054 <br />MAIL @RNM- ENGINEERS.COM <br />WWW.RNM- ENGINEERS.COM <br />NC CERT. NO. C -0149 <br />© 2018 <br />SEALS: <br />M ZO w Q <br />, �lIIIl1I[!!!lr r <br />r <br />W W w <br />0 < Z: <br />Z N <br />N <br />U W U <br />° <br />o_ <br />02 539 0 <br />0 <br />Q W w W <br />�•' J °aO° LVC- '� ° °� °�y4 <br />in Ld <br />_J <br />N of M <br />r <br />s V <br />= N =) Z <br />I- Cl- <br />V <br />Z <br />O <br />O <br />CU <br />r <br />r F Z <br />� <br />Q O <br />0 Q <br />z::D <br />::Do <br />O ° <br />Uo <br />uJ z u <br />Q O <br />Z _J o <br />Q <br />Q m <br />pC z J <br />LU <br />O2 <br />LU <br />U) <br />w <br />0 <br />o' <br />REVISIONS /SU BM ISSIONS <br />NO <br />DATE <br />ISSUED FOR <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />SHEET TITLE: <br />U.L. DETAILS <br />ISSUED FOR: <br />CONSTRUCTION <br />DRAWN BY: <br />DJM <br />DRAWING NO. <br />APPROVED BY: <br />MRM <br />PROJECT #: <br />2018034 <br />M3.0 <br />DATE: <br />05/24/2018 <br />OF 3 SHEEfS <br />