Browse
Search
2018-425-E AMS - Sasser Companies Annex upfit
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-425-E AMS - Sasser Companies Annex upfit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2018 1:51:04 PM
Creation date
8/24/2018 9:08:20 AM
Metadata
Fields
Template:
Contract
Date
8/7/2018
Contract Starting Date
8/7/2018
Contract Ending Date
9/7/2018
Contract Document Type
Agreement - Construction
Amount
$390,849.00
Document Relationships
R 2018-425 AMS - Sasser Companies BOE upfit
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 237700 - VIBRATION AND SEISMIC CONTROLS FOR HVAC <br />PART 3 - EXECUTION <br />3.1 APPLICATIONS <br />A. Multiple Pipe Supports: Secure pipes to trapeze member with clamps approved for application by an agency <br />acceptable to authorities having jurisdiction. <br />B. Hanger Rod Stiffeners: Install hanger rod stiffeners where indicated or scheduled on Delegated Design <br />Drawings to receive them and where required to prevent buckling of hanger rods due to seismic forces. <br />C. Strength of Support and Seismic - Restraint Assemblies: Where not indicated, select sizes of components so <br />strength will be adequate to carry present and future static and seismic loads within specified loading limits. <br />3.2 VIBRATION- CONTROL AND SEISMIC - RESTRAINT DEVICE INSTALLATION <br />A. Equipment Restraints: <br />1. Install resilient bolt isolation washers on equipment anchor bolts where clearance between anchor and <br />adjacent surface exceeds 0.125 inches. <br />2. Install seismic - restraint devices using methods approved by an agency acceptable to authorities <br />having jurisdiction providing required submittals for component. <br />B. Piping Restraints: <br />1. Comply with requirements in MSS SP -127. <br />C. Install cables so they do not bend across edges of adjacent equipment or building structure. <br />D. Install seismic - restraint devices using methods approved by an agency acceptable to authorities having <br />jurisdiction providing required submittals for component. <br />E. Install bushing assemblies for anchor bolts for floor- mounted equipment, arranged to provide resilient media <br />between anchor bolt and mounting hole in concrete base. <br />F. Attachment to Structure: If specific attachment is not indicated, anchor bracing to structure at flanges of <br />beams, at upper truss chords of bar joists, or at concrete members. <br />G. Drilled -in Anchors: <br />1. Identify position of reinforcing steel and other embedded items prior to drilling holes for anchors. Do <br />not damage existing reinforcing or embedded items during coring or drilling. Notify the structural <br />engineer if reinforcing steel or other embedded items are encountered during drilling. Locate and <br />avoid prestressed tendons, electrical and telecommunications conduit, and gas lines. <br />2. Do not drill holes in concrete or masonry until concrete, mortar, or grout has achieved full design <br />strength. <br />3. Wedge Anchors: Protect threads from damage during anchor installation. Heavy -duty sleeve anchors <br />shall be installed with sleeve fully engaged in the structural element to which anchor is to be fastened. <br />4. Set anchors to manufacturer's recommended torque, using a torque wrench. <br />5. Install zinc - coated steel anchors for interior and stainless steel anchors for exterior applications. <br />3.3 ACCOMMODATION OF DIFFERENTIAL SEISMIC MOTION <br />A. Install flexible connections in piping where they cross seismic joints, where adjacent sections or branches are <br />supported by different structural elements, and where the connections terminate with connection to equipment <br />that is anchored to a different structural element from the one supporting the connections as they approach <br />equipment. Comply with requirements in Division 22 Section "Domestic Water Piping" for piping flexible <br />connections. <br />Reece, Noland & McElrath, Inc. 237700-2 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.