Browse
Search
2018-425-E AMS - Sasser Companies Annex upfit
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-425-E AMS - Sasser Companies Annex upfit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2018 1:51:04 PM
Creation date
8/24/2018 9:08:20 AM
Metadata
Fields
Template:
Contract
Date
8/7/2018
Contract Starting Date
8/7/2018
Contract Ending Date
9/7/2018
Contract Document Type
Agreement - Construction
Amount
$390,849.00
Document Relationships
R 2018-425 AMS - Sasser Companies BOE upfit
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 237000 - PENETRATION FIRESTOPPING <br />1.4 QUALITY ASSURANCE <br />A. Fire - Test - Response Characteristics: Provide through - penetration firestop systems that comply with <br />the following requirements and those specified in Part 1 "Performance Requirements" Article: <br />1. Firestopping tests are performed by a qualified testing and inspecting agency. A qualified <br />testing and inspecting agency is UL, or another agency performing testing and follow -up <br />inspection services for firestop systems acceptable to authorities having jurisdiction. <br />2. Through - penetration firestop systems are identical to those tested per testing standard <br />referenced in "Part 1 Performance Requirements" Article. Provide rated systems bearing <br />classification marking of qualified testing and inspecting agency. <br />B. Coordinate construction of openings and penetrating items to ensure that through- penetration <br />firestop systems are installed according to specified requirements. <br />C. Do not cover up through - penetration firestop system installations that will become concealed <br />behind other construction until each installation has been examined by Owner's inspecting agency <br />and building inspector, if required by authorities having jurisdiction. <br />PART 2- PRODUCTS <br />2.1 MANUFACTURERS <br />A. Products: Subject to compliance with requirements, provide one of the through - penetration <br />firestop systems indicated for each application on Drawings or that are produced by one of the <br />following manufacturers: <br />1. Grace, W. R. & Co. - Conn. <br />2. Hilti, Inc. <br />3. Johns Manville. <br />4. Nelson Firestop Products. <br />5. 3M; Fire Protection Products Division. <br />6. Tremco; Sealant/Weatherproofing Division. <br />7. USG Corporation. <br />2.2 FIRESTOPPING <br />A. Compatibility: Provide through- penetration firestop systems that are compatible with one another; <br />with the substrates forming openings; and with the items, if any, penetrating through- penetration <br />firestop systems, under conditions of service and application, as demonstrated by through - <br />penetration firestop system manufacturer based on testing and field experience. <br />B. Accessories: Provide components for each through - penetration firestop system that are needed to <br />install fill materials and to comply with Part 1 "Performance Requirements" Article. Use only <br />components specified by through- penetration firestop system manufacturer and approved by <br />qualified testing and inspecting agency for firestop systems indicated. <br />Reece, Noland & McElrath, Inc. 237000-2 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />