Browse
Search
2018-425-E AMS - Sasser Companies Annex upfit
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-425-E AMS - Sasser Companies Annex upfit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2018 1:51:04 PM
Creation date
8/24/2018 9:08:20 AM
Metadata
Fields
Template:
Contract
Date
8/7/2018
Contract Starting Date
8/7/2018
Contract Ending Date
9/7/2018
Contract Document Type
Agreement - Construction
Amount
$390,849.00
Document Relationships
R 2018-425 AMS - Sasser Companies BOE upfit
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 236000 - COMMON WORK RESULTS FOR HVAC <br />Any conflicts corrected by relocation or elevation changes do not constitute extra work. <br />3.9 INCIDENTAL CONSTRUCTION WORK <br />A. All blocking for openings for piping in concrete floors, masonry walls or partitions shall be provided by this <br />Contractor. <br />1. This Contractor shall do all cutting and fitting of his work and of other work that may be required to <br />make the several parts come together properly and to fit his work to receive or be received by the work <br />of other Contractors as shown upon, or reasonably implied by the drawings and specifications. <br />2. He shall properly complete and finish up his work after other Contractors have finished as the Designer <br />may direct. <br />B. All excavating required for the installation of this system shall be done by this Contractor. <br />1. Backfill shall be accomplished as specified in appropriate section of specifications. <br />C. Chases are prohibited in masonry walls which are not to be plastered or paneled. <br />1. Set piping, blocking, carriers, etc. indicated to be concealed before walls are constructed in order that <br />walls may be constructed around them. <br />2. This Contractor shall furnish all sleeves in floors, beams, walls, etc., for each such penetration as <br />needed for installing his work and installation of sleeves by General Contractor. <br />D. Unless otherwise noted, the General Contractor will provide openings and lintels as new construction <br />progresses, but this Contractor shall fully designate his requirements prior to construction. <br />1. Failure to furnish his requirements prior to building construction and failure to coordinate his work with <br />the building construction shall make this Contractor responsible for removing, replacing and painting <br />building construction as required for installation of his work. <br />3.10 ACCESS DOORS <br />A. Provide and install access doors in walls, ceilings, etc. as required for access to valves, dampers, fire <br />dampers, controls, and other devices requiring access in ceilings, chases, soffits, etc. <br />B. Access doors in non -fire rated walls or ceilings shall be as follows: <br />1. Nominal 24" x 24" minimum size. <br />2. 16 -gage steel frame with 14 -gage door panel and galvanized steel drywall bead. <br />3. Flush style with provision to conceal flange with drywall cement. <br />4. Double- acting concealed spring hinges to allow opening to 175 degrees. <br />5. Flush, Allen -head operated with steel cam. <br />6. Gray prime - painted steel, for painting to match adjacent finished surfaces. <br />7. Basis of Design: Milcor Style DW; Comparable Products by Karp, Elmdor, Acudor. <br />C. Access doors in fire -rated walls or ceilings shall be as follows: <br />1. Nominal 24" x 24" minimum size. <br />2. UL 1 -1/2 hour, Class B fire rating. <br />3. Prime - painted stainless steel: 16 -gage frame with 20 -gage door panel, for painting to match adjacent <br />finished surfaces. <br />4. 2" mineral fiber insulation between inner and outer panel. <br />5. Continuous hinge, steel with stainless steel pin. <br />6. Self- closing and self - latching panel closer. <br />7. Flush mounted paddle latch and locking system with flush, key- operated cylinder lock with two keys. <br />8. Basis of Design: Milcor Style UFR; Comparable Products by Karp, Elmdor, Acudor. <br />3.11 SUPERVISION <br />A. This Contractor shall have in charge of the work at all times during construction a thoroughly competent <br />foreman with extensive experience in the work to be performed under this contract. <br />1. Anyone deemed not capable by the Designer shall be replaced immediately upon request, and after <br />satisfactory foreman has been assigned, he shall not be withdrawn without the written consent of the <br />Designer. <br />Reece, Noland & McElrath, Inc. 236000-4 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.