DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 239700 - LOUVERS AND VENTS <br />C. Galvanized -Steel Sheet: ASTM A 653/A 653M, G60 zinc coating, mill phosphatized. <br />D. Stainless -Steel Sheet: ASTM A 240/A 240M, Type 304, No. 4 finish. <br />E. Fasteners: Use types and sizes to suit unit installation conditions. <br />1. For fastening aluminum, use aluminum or 300 series stainless -steel fasteners. <br />2. For fastening galvanized steel, use hot - dip - galvanized steel or 300 series stainless -steel <br />fasteners. <br />3. For fastening stainless steel, use 300 series stainless -steel fasteners. <br />4. For color - finished louvers, use fasteners with heads that match color of louvers. <br />F. Bituminous Paint: Cold- applied asphalt emulsion complying with ASTM D 1187. <br />2.2 FABRICATION, GENERAL <br />A. Fabricate frames, including integral sills, to fit in openings of sizes indicated, with allowances made <br />for fabrication and installation tolerances, adjoining material tolerances, and perimeter sealant joints. <br />B. Join frame members to each other and to fixed louver blades with fillet welds concealed from view <br />unless otherwise indicated or size of louver assembly makes bolted connections between frame <br />members necessary. <br />2.3 FIXED, EXTRUDED - ALUMINUM LOUVERS <br />A. Horizontal, Drainable -Blade Louver: <br />1. Basis -of- Design Product: Subject to compliance with requirements, provide product indicated <br />on Drawings or comparable product by one of the following: <br />a. Air Balance Inc.; a Mestek company. <br />b. Air Flow Company, Inc. <br />C. Airolite Company, LLC (The). <br />d. All -Lite Architectural Products. <br />e. American Warming and Ventilating, Inc.; a Mestek company. <br />f. Arrow United Industries; a division of Mestek, Inc. <br />g. Carnes Company, Inc. <br />h. Cesco Products; a division of Mestek, Inc. <br />i. Construction Specialties, Inc. <br />j. Dowco Products Group; Safe -Air of Illinois, Inc. <br />k. Greenheck Fan Corporation. <br />I. Industrial Louvers, Inc. <br />M. Louvers & Dampers, Inc.; a division of Mestek, Inc. <br />n. Metal Form Manufacturing Inc. <br />o. NCA Manufacturing, Inc. <br />P. Nystrom Building Products. <br />q. Reliable Products, Inc. <br />r. Ruskin Company; Tomkins PLC. <br />S. United Enertech Corp. <br />t. Vent Products Company, Inc. <br />2. Louver Depth: 4 inches. <br />3. Frame and Blade Nominal Thickness: Not less than 0.060 inch for blades and 0.080 inch for <br />frames. <br />4. Louver Performance Ratings: <br />a. Free Area: Not less than 7.5 sq. ft. for 48 -inch- wide by 48 -inch- high louver. <br />b. Point of Beginning Water Penetration: Not less than 900 fpm. <br />C. Air Performance: Not more than 0.10 -inch wg static pressure drop at 750 -fpm free - <br />area intake velocity. <br />d. Air Performance: Not more than 0.15 -inch wg static pressure drop at 900 -fpm free - <br />area exhaust velocity. <br />5. AMCA Seal: Mark units with AMCA Certified Ratings Seal. <br />Reece, Noland & McElrath, Inc. 239700-2 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />