Browse
Search
2018-425-E AMS - Sasser Companies Annex upfit
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-425-E AMS - Sasser Companies Annex upfit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2018 1:51:04 PM
Creation date
8/24/2018 9:08:20 AM
Metadata
Fields
Template:
Contract
Date
8/7/2018
Contract Starting Date
8/7/2018
Contract Ending Date
9/7/2018
Contract Document Type
Agreement - Construction
Amount
$390,849.00
Document Relationships
R 2018-425 AMS - Sasser Companies BOE upfit
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 239500 - MULTI - INDOOR VRV SYSTEM <br />2. The unit shall be compatible with interfacing with a BMS system via op- <br />tional LonWorks or BACnet gateways. <br />3. The unit shall be compatible with a Daikin Intelligent Touch Manager ad- <br />vanced multi -zone controller. <br />J. Optional Accessories Available: <br />1. Field installed 3 -20kW electric heaters (HKR -03, HKR -05C, HKR -06, <br />HKR -08C, HKR -10C). The indoor units shall have circuit breakers sup- <br />plied with each electric heat kit. <br />2. Air filter (FIL 36 -42, FIL 48 -61). <br />3. Insulation kit for vertical (DPI 36- 42/20, DPI 48- 61/20) and horizontal <br />(DPIH 36 -42, DPIH 48 -61) configurations. <br />4. BRC4C84 wireless controller. <br />4.12 FXMQ_MF - OUTSIDE AIR PROCESSING UNIT <br />A. General: Daikin indoor unit FXMQ_MF shall be a built -in ceiling concealed <br />fan coil unit, operable with refrigerant R -410A, equipped with an electronic <br />expansion valve, for installation into the ceiling cavity. The unit shall be ca- <br />pable of introducing up to 100% outside air controlled to a fixed discharge air <br />temperature. It is constructed of a galvanized steel casing. It shall be availa- <br />ble in capacities from 48,000 Btu /h to 96,000 Btu /h. Model numbers are <br />FXMQ48MFVJU, FXMQ72MFVJU and FXMQ96MVJU to be connected to <br />outdoor unit model RXYQ / RXYMQ / RWEYQ heat pump and REYQ / <br />RWEYQ heat recovery model. It shall be a horizontal discharge air with hori- <br />zontal return air configuration. All models feature a low height cabinet mak- <br />ing them applicable to ceiling pockets that tend to be shallow. Computerized <br />PID control shall be used to control superheat to deliver a comfortable room <br />temperature condition. The indoor units sound pressure shall range from 42 <br />dB(A) to 47 dB(A) at low speed measured 5 feet below the ducted unit. <br />B. Performance: Each unit's performance is based on nominal operating condi- <br />tions: <br />Model Number <br />Cooling <br />(Outdoor 91 T DB / 82 °F WB, <br />Discharge 64T DB, 25 ft pipe length) <br />Heating <br />(Outdoor 32T DB / 27T WB, <br />Discharge 77T DB, 25 ft pipe length) <br />FXMQ48MFVJU <br />48,000 <br />30,000 <br />FXMQ72MFVJU <br />72,000 <br />47,000 <br />FXMQ96MFVJU <br />96,000 <br />59,000 <br />C. Indoor Unit: <br />1. The Daikin indoor unit FXMQ_MF shall be completely factory assembled <br />and tested. Included in the unit is factory wiring, piping, electronic propor- <br />tional expansion valve, control circuit board, fan motor thermal protector, <br />flare connections, self- diagnostics, auto - restart function, 3- minute fused <br />time delay and test run switch. <br />2. Indoor unit and refrigerant pipes will be charged with dehydrated air prior <br />to shipment from the factory. <br />3. Both refrigerant lines shall be insulated from the outdoor unit. <br />4. The indoor units shall be equipped with a discharge air thermistor. <br />5. The indoor unit will be separately powered with 208- 230V/1- phase /60Hz. <br />6. The voltage range will be 253 volts maximum and 187 volts minimum. <br />D. Unit Cabinet: <br />Reece, Noland & McElrath, Inc. 239500-60 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.