Browse
Search
2018-425-E AMS - Sasser Companies Annex upfit
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-425-E AMS - Sasser Companies Annex upfit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2018 1:51:04 PM
Creation date
8/24/2018 9:08:20 AM
Metadata
Fields
Template:
Contract
Date
8/7/2018
Contract Starting Date
8/7/2018
Contract Ending Date
9/7/2018
Contract Document Type
Agreement - Construction
Amount
$390,849.00
Document Relationships
R 2018-425 AMS - Sasser Companies BOE upfit
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 239500 - MULTI - INDOOR VRV SYSTEM <br />2. Transmission (control) wiring between the indoor and outdoor unit shall <br />be a maximum of 3,280 feet (total 6,560 feet). <br />Model Number <br />Cooling <br />(Indoor 80 °F DB / 67 °F WB, <br />Outdoor 95 °F DB, 25 ft pipe length) <br />Heating <br />(Indoor 47 °F DB / 43 °F W B, <br />Outdoor 70 °F DB, 25 ft pipe length) <br />FXAQ07PVJU <br />7,500 <br />8,500 <br />FXAQ09PVJU <br />9,500 <br />10,500 <br />FXAQ12PVJU <br />12,000 <br />13,500 <br />FXAQ18PVJU <br />18,000 <br />20,000 <br />FXAQ24PVJU <br />24,000 <br />26,500 <br />3. Transmission (control) wiring between the indoor unit and remote control- <br />ler shall be a maximum distance of 1,640 feet. <br />Control: <br />1. The unit shall have controls provided by Daikin to perform input functions <br />necessary to operate the system. <br />2. The unit shall be compatible with interfacing with a BMS system via op- <br />tional LonWorks or BACnet gateways. <br />3. The unit shall be compatible with a Daikin Intelligent Touch Manager ad- <br />vanced multi -zone controller. <br />Optional Accessories Available: <br />1. Remote "in- room" sensor kit KRCS01 -113. <br />2. A condensate pump (DACA- CP3 -1). <br />4.08 FXAQ -WALL MOUNTED UNIT <br />A. General: Daikin indoor unit FXAQ shall be a wall mounted fan coil unit, oper- <br />able with refrigerant R -410A, equipped with an electronic expansion valve, for <br />installation onto a wall within a conditioned space. This compact design with <br />finished white casing shall be available in capacities from 7,500 Btu /h to <br />24,000 Btu /h. Model numbers are FXAQ07PVJU, FXAQ09PVJU, <br />FXAQ12PVJU, FXAQ18PVJU and FXAQ24PVJU to be connected to outdoor <br />unit model RXYQ / RXYMQ / RWEYQ heat pump and REYQ / RWEYQ heat <br />recovery model. Computerized PID control shall be used to control super- <br />heat to deliver a comfortable room temperature condition. The unit shall be <br />equipped with a programmed drying mechanism that dehumidifies while limit- <br />ing changes in room temperature when used with Daikin remote control <br />BRC1 E72, BRC1 E73 and BRC2A71. A mildew - proof, polystyrene conden- <br />sate drain pan and resin net mold resistant filter shall be included as standard <br />equipment. The indoor units sound pressure shall range from 31 dB(A) to 41 <br />dB(A) at low speed measured at 3.3 feet below and from the unit. <br />B. Performance: Each unit's performance is based on nominal operating condi- <br />tions: <br />Reece, Noland & McElrath, Inc. 239500-52 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.