Browse
Search
2018-425-E AMS - Sasser Companies Annex upfit
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-425-E AMS - Sasser Companies Annex upfit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2018 1:51:04 PM
Creation date
8/24/2018 9:08:20 AM
Metadata
Fields
Template:
Contract
Date
8/7/2018
Contract Starting Date
8/7/2018
Contract Ending Date
9/7/2018
Contract Document Type
Agreement - Construction
Amount
$390,849.00
Document Relationships
R 2018-425 AMS - Sasser Companies BOE upfit
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 239500 - MULTI - INDOOR VRV SYSTEM <br />sensor for detecting the temperature can be placed away from the <br />indoor unit (branch wiring is included in the kit). <br />2. MERV 13 Filter kit. Can be configured for right or left access. Filters re- <br />placeable without tools. <br />3. Air side Economizer designed for connection to the rear of FXMQ30- <br />54PBVJU. <br />4.06 FXDQ- SLIM DUCT CONCEALED CEILING UNIT <br />A. General: Daikin indoor unit model FXDQ shall be a Slim, built -in ceiling con- <br />cealed fan coil unit, operable with R -410A refrigerant, equipped with an elec- <br />tronic expansion valve, for installation into the ceiling cavity. The unit shall be <br />constructed of a galvanized steel casing. It shall be available in capacities <br />from 7,000 Btu /h to 24,000 Btu /h. Model numbers are FXDQ07MVJU, <br />FXDQ09MVJU, FXDQ12MVJU, FXDQ18MVJU, and FXDQ24MVJU to be <br />connected to outdoor unit model RXYQ / RXYMQ / RWEYQ heat pump and <br />REYQ / RWEYQ heat recovery model. It shall be a horizontal discharge air <br />with horizontal return air or bottom return air configuration. All models feature <br />a very low height (7 -7/8 ") making them applicable to ceiling pockets that tend <br />to be shallow. Computerized PID control shall be used to control superheat <br />to deliver a comfortable room temperature condition. The unit shall be <br />equipped with a programmed drying mechanism that dehumidifies while limit- <br />ing changes in room temperature when used with Daikin remote control <br />BRC1E72, BRC1E73 and BRC2A71. Included as standard equipment, a <br />long -life filter that is mold resistant and a condensate drain pan and drain <br />pump kit that pumps to 23 -5/8" from the drain pipe opening. The indoor units <br />sound pressure level shall range from 29 dB(A) to 32 dB(A) at low speed and <br />33 dB(A) to 36 dB(A) at high speed 5 feet below the suction grille. <br />B. Performance: Each unit's performance is based on nominal operating condi- <br />tions: <br />Model Number <br />Cooling <br />(Indoor 80T DB / 67T WB, <br />Outdoor 95T DB, 25 ft pipe length) <br />Heating <br />(Indoor 47T DB 143T WB, <br />Outdoor 70T DB, 25 ft pipe length) <br />FXD007MVJU <br />7,500 <br />8,500 <br />FXDQ09MVJU <br />9,500 <br />10,500 <br />FXDQ12MVJU <br />12,000 <br />13,500 <br />FXDQ18MVJU <br />18,000 <br />20,000 <br />FXDQ24MVJU <br />24,000 <br />27,000 <br />C. Indoor Unit: <br />1. The Daikin indoor unit FXDQ shall be completely factory assembled and <br />tested. Included in the unit is factory wiring, piping, electronic proportional <br />expansion valve, control circuit board, fan motor thermal protector, flare <br />connections, condensate drain pan, condensate drain pump, condensate <br />safety shutoff and alarm, self- diagnostics, auto - restart function, 3- minute <br />fused time delay, and test run switch. The unit shall have adjustable ex- <br />ternal static pressure capabilities. <br />2. Indoor unit and refrigerant pipes will be charged with dehydrated air prior <br />to shipment from the factory. <br />3. Both refrigerant lines shall be insulated from the outdoor unit. <br />Reece, Noland & McElrath, Inc. 239500-48 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.