Browse
Search
2018-425-E AMS - Sasser Companies Annex upfit
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-425-E AMS - Sasser Companies Annex upfit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2018 1:51:04 PM
Creation date
8/24/2018 9:08:20 AM
Metadata
Fields
Template:
Contract
Date
8/7/2018
Contract Starting Date
8/7/2018
Contract Ending Date
9/7/2018
Contract Document Type
Agreement - Construction
Amount
$390,849.00
Document Relationships
R 2018-425 AMS - Sasser Companies BOE upfit
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 239500 - MULTI - INDOOR VRV SYSTEM <br />1. The unit shall have controls provided by Daikin to perform input functions <br />necessary to operate the system. <br />2. The unit shall be compatible with interfacing with a BMS system via op- <br />tional LonWorks or BACnet gateways. <br />3. The unit shall be compatible with a Daikin Intelligent Touch Manager ad- <br />vanced multi -zone controller. <br />J. Optional Accessories Available: <br />1. Direct fresh air intake kit (KDDQ44X60). <br />2. Supply air duct connections. <br />3. Remote "in- room" sensor kit (KRCS01 -1B). <br />i. The Daikin wall mounted, hard wired remote sensor kit is recom- <br />mended for ceiling- embedded type fan coils, which often result in a <br />difference between set temperature and actual temperature. The sen- <br />sor for detecting the temperature can be placed away from the indoor <br />unit (branch wiring is included in the kit). <br />4.03 FXMQ -M - CONCEALED CEILING DUCTED UNIT (Med. Static) <br />A. General: Daikin indoor unit FXMQ -M shall be a built -in ceiling concealed fan <br />coil unit, operable with refrigerant R-41 OA, equipped with an electronic ex- <br />pansion valve, for installation into the ceiling cavity. It is constructed of a gal- <br />vanized steel casing. It shall be available in capacities from 72,000 Btu /h to <br />96,000 Btu /h. Model numbers are FXMQ72MVJU and FXMQ96MVJU to be <br />connected to outdoor unit model RXYQ / RWEYQ heat pump and REYQ / <br />RWEYQ heat recovery model. It shall be a horizontal discharge air with hori- <br />zontal return air configuration. All models feature a low height cabinet mak- <br />ing them applicable to ceiling pockets that tend to be shallow. Computerized <br />PID control shall be used to control superheat to deliver a comfortable room <br />temperature condition. The unit shall be equipped with a programmed drying <br />mechanism that dehumidifies while limiting changes in room temperature <br />when used with Daikin remote control BRC1 E72, BRC1 E73 and BRC2A71. <br />The indoor units sound pressure shall be 48 dB(A) at low speed measured 5 <br />feet below the ducted unit. <br />B. Performance: Each unit's performance is based on nominal operating condi- <br />tions: <br />C. Indoor Unit: <br />1. The Daikin indoor unit FXMQ -M shall be completely factory assembled <br />and tested. Included in the unit is factory wiring, piping, electronic propor- <br />tional expansion valve, control circuit board, fan motor thermal protector, <br />flare connections, self- diagnostics, auto - restart function, 3- minute fused <br />time delay, and test run switch. The unit shall have an adjustable external <br />static pressure switch. <br />2. Indoor unit and refrigerant pipes will be charged with dehydrated air prior <br />to shipment from the factory. <br />3. Both refrigerant lines shall be insulated from the outdoor unit. <br />Reece, Noland & McElrath, Inc. 239500-41 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />Model Number <br />Cooling <br />Heating <br />(Indoor 80T DB / 67T WB, <br />(Indoor 47T DB / 43T WB, <br />Outdoor 95T DB, 25 ft pipe length) <br />Outdoor 70 °F DB, 25 ft pipe length) <br />FXMQ72MVJU <br />72,000 <br />96,000 <br />FXMQ96MVJU <br />96,000 <br />108,000 <br />C. Indoor Unit: <br />1. The Daikin indoor unit FXMQ -M shall be completely factory assembled <br />and tested. Included in the unit is factory wiring, piping, electronic propor- <br />tional expansion valve, control circuit board, fan motor thermal protector, <br />flare connections, self- diagnostics, auto - restart function, 3- minute fused <br />time delay, and test run switch. The unit shall have an adjustable external <br />static pressure switch. <br />2. Indoor unit and refrigerant pipes will be charged with dehydrated air prior <br />to shipment from the factory. <br />3. Both refrigerant lines shall be insulated from the outdoor unit. <br />Reece, Noland & McElrath, Inc. 239500-41 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.