Browse
Search
2018-425-E AMS - Sasser Companies Annex upfit
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-425-E AMS - Sasser Companies Annex upfit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2018 1:51:04 PM
Creation date
8/24/2018 9:08:20 AM
Metadata
Fields
Template:
Contract
Date
8/7/2018
Contract Starting Date
8/7/2018
Contract Ending Date
9/7/2018
Contract Document Type
Agreement - Construction
Amount
$390,849.00
Document Relationships
R 2018-425 AMS - Sasser Companies BOE upfit
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 239500 - MULTI - INDOOR VRV SYSTEM <br />Self- Cleaning Filter Panel, which performs automatic filter cleaning up to <br />once a day, with dust collection box that indicates when to be emptied. <br />Remote "in- room" sensor kit (KRCS01 -4B). <br />i. The Daikin wall mounted, hard wired remote sensor kit is recom- <br />mended for when a NAV controller is not used or when the NAV con- <br />troller is not located in the space that is being controlled. The sensor <br />for detecting the temperature can be placed away from the indoor unit <br />(branch wiring is included in the kit). <br />4.02 FXZQ -4 WAY CEILING CASSETTE UNIT (2'x2') <br />A. General: Daikin indoor unit model FXZQ shall be a ceiling cassette fan coil <br />unit, operable with R-41 DA refrigerant, equipped with an electronic expansion <br />valve, for installation into the ceiling cavity equipped with an air panel grill. It <br />shall be available in capacities from 7,500 Btu /h to 18,000 Btu /h. Model <br />numbers are FXZQ07MVJU9, FXZQ09MVJU9, FXZQ12MVJU9, <br />FXZQ15MVJU9, FXZQ18MVJU9 to be connected to outdoor unit model <br />RXYQ / RXYMQ / RWEYQ heat pump and REYQ / RWEYQ heat recovery <br />model. It shall be a four -way air distribution type, white (RAL9010), impact <br />resistant with a washable decoration panel. The supply air is distributed via <br />motorized louvers which can be horizontally and vertically adjusted from 0° to <br />90 °. Computerized PID control shall be used to control superheat to deliver a <br />comfortable room temperature condition. The unit shall be equipped with a <br />programmed drying mechanism that dehumidifies while limiting changes in <br />room temperature when used with Daikin remote control BRC1 E72, <br />BRC1 E73 and BRC2A71. The indoor units sound pressure shall range from <br />29 dB(A) to 34 dB(A) at low speed measured at 5 feet below the unit. <br />B. Performance: Each unit's performance is based on nominal operating <br />conditions: <br />Model Number <br />Cooling <br />(Indoor 80 °F DB / 67 °F WB, <br />Outdoor 95 °F DB, 25 ft pipe length) <br />Heating <br />(Indoor 47 °F DB / 43 °F W B, <br />Outdoor 70T DB, 25 ft pipe length) <br />FXZQ07MVJU9 <br />7,500 <br />8,700 <br />FXZQ09MVJU9 <br />9,500 <br />11,100 <br />FXZQ12MVJU9 <br />12,000 <br />14,000 <br />FXZQ15MVJU9 <br />15000 <br />17,500 <br />FXZQ18MVJU9 <br />18,000 <br />21,000 <br />C. Indoor Unit: <br />1. The Daikin indoor unit FXZQ shall be completely factory assembled and <br />tested. Included in the unit is factory wiring, piping, electronic proportional <br />expansion valve, control circuit board, fan motor thermal protector, flare <br />connections, condensate drain pan, condensate drain pump, condensate <br />safety shutoff and alarm, self- diagnostics, auto - restart function, 3- minute <br />fused time delay, and test run switch. <br />2. Indoor unit and refrigerant pipes will be charged with dehydrated air prior <br />to shipment from the factory. <br />3. Both refrigerant lines shall be insulated from the outdoor unit. <br />4. The 4 -way supply air flow can be field modified to 3 -way and 2 -way air- <br />flow to accommodate various installation configurations including corner <br />installations. <br />Reece, Noland & McElrath, Inc. 239500-39 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />