Browse
Search
2018-425-E AMS - Sasser Companies Annex upfit
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-425-E AMS - Sasser Companies Annex upfit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2018 1:51:04 PM
Creation date
8/24/2018 9:08:20 AM
Metadata
Fields
Template:
Contract
Date
8/7/2018
Contract Starting Date
8/7/2018
Contract Ending Date
9/7/2018
Contract Document Type
Agreement - Construction
Amount
$390,849.00
Document Relationships
R 2018-425 AMS - Sasser Companies BOE upfit
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 239500 — MULTI - INDOOR VRV SYSTEM <br />1�21►F <br />1. The condensing unit shall consist of one or more propeller type, direct -drive 500 or 60OW <br />fan motors that have multiple speed operation via a DC (digitally commutating) inverter. <br />Reference table below. <br />MODEL NUMBER <br />FAN MOTOR OUTPUT (W) & QUANTITY <br />REYQ72TAYD* <br />500 x 1 <br />REYQ96TAYD* <br />600 x 600 <br />REYQ120TAYD* <br />600 x 600 <br />REYQ144TAYD* <br />600 x 600 <br />REYQ168TAYD* <br />600 x 600 <br />REYQ192TAYD* <br />(500 x 1) + (600 x 2) <br />REYQ216TAYD* <br />(600 x 2) + (600 x 2) <br />REYQ240TAYD* <br />(600 x 2) + (600 x 2) <br />REYQ264TAYD* <br />(600 x 2) + (600 x 2) <br />REYQ288TAYD* <br />(600 x 2) + (600 x 2) <br />REYQ312TAYD* <br />(600 x 2) + (600 x 2) <br />REYQ336TAYD* <br />(600 x 2) + (600 x 2) <br />REYQ360TAYD* <br />(600 x 2) + (600 x 2) + (600 x 2) <br />REYQ384TAYD* <br />(600 x 2) + (600 x 2) + (600 x 2) <br />REYQ408TAYD* <br />(600 x 2) + (600 x 2) + (600 x 2) <br />REYQ432TAYD* <br />(600 x 2) + (600 x 2) + (600 x 2) <br />REYQ456TAYD* <br />(600 x 2) + (600 x 2) + (600 x 2) <br />2. The condensing unit fan motor shall have multiple speed operation of the DC (digitally <br />commutating) inverter type, and be of high external static pressure and shall be factory <br />set as standard at 0.12 in. WG. Afield setting switch to a maximum 0.32 in. WG pres- <br />sure is available to accommodate field applied duct for indoor mounting of condensing <br />units. <br />3. The fan shall be a vertical discharge configuration with a nominal airflow maximum range <br />of 5,544 CFM to 24,684 CFM dependent on model specified. <br />4. The fan motor shall have inherent protection and permanently lubricated bearings and be <br />mounted. <br />5. The fan motor shall be provided with a fan guard to prevent contact with moving parts. <br />Reece, Noland & McElrath, Inc. 239500-27 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.