Browse
Search
2018-425-E AMS - Sasser Companies Annex upfit
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-425-E AMS - Sasser Companies Annex upfit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2018 1:51:04 PM
Creation date
8/24/2018 9:08:20 AM
Metadata
Fields
Template:
Contract
Date
8/7/2018
Contract Starting Date
8/7/2018
Contract Ending Date
9/7/2018
Contract Document Type
Agreement - Construction
Amount
$390,849.00
Document Relationships
R 2018-425 AMS - Sasser Companies BOE upfit
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 239500 — MULTI - INDOOR VRV SYSTEM <br />►JII�[�[c71 <br />1. The control voltage between the indoor and condensing unit shall be 16VDC non - <br />shielded, stranded 2 conductor cable. <br />2. The control wiring shall be a two -wire multiplex transmission system, making it possible <br />to connect multiple indoor units to one condensing unit with one 2 -cable wire, thus simpli- <br />fying the wiring installation. <br />3. The control wiring maximum lengths shall be as shown below: <br />C. REFRIGERANT PIPING: <br />1. The system shall be capable of refrigerant piping up to 540ft (165m) actual or 623ft <br />(190m) equivalent from the condensing unit to the furthest indoor unit, a total combined <br />liquid line length of 3,280ft (1,000m) of piping between the condensing and indoor units <br />with 295ft (90m) maximum vertical difference, without any oil traps or additional compo- <br />nents. <br />2. REFNETTm piping joints and headers shall be used to ensure proper refrigerant balance <br />and flow for optimum system capacity and performance. <br />a. T style joints shall not be acceptable as this will negatively impact proper refrigerant <br />balance and flow for optimum system capacity and performance. <br />Reece, Noland & McElrath, Inc. 239500-23 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />CONDENSER TO <br />CONDENSER TO <br />INDOOR UNIT TO <br />CENTRAL <br />INDOOR UNIT <br />REMOTE CONTROL <br />CONTROLLER <br />CONTROL WIRING <br />6,560 ft (2,000 m) <br />3,280 ft (1,000 m) <br />1,640 ft (500 m) <br />LENGTH <br />WIRE TYPE <br />16/18 AWG, 2 wire, non - polarity, non - shielded, stranded <br />C. REFRIGERANT PIPING: <br />1. The system shall be capable of refrigerant piping up to 540ft (165m) actual or 623ft <br />(190m) equivalent from the condensing unit to the furthest indoor unit, a total combined <br />liquid line length of 3,280ft (1,000m) of piping between the condensing and indoor units <br />with 295ft (90m) maximum vertical difference, without any oil traps or additional compo- <br />nents. <br />2. REFNETTm piping joints and headers shall be used to ensure proper refrigerant balance <br />and flow for optimum system capacity and performance. <br />a. T style joints shall not be acceptable as this will negatively impact proper refrigerant <br />balance and flow for optimum system capacity and performance. <br />Reece, Noland & McElrath, Inc. 239500-23 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.