Browse
Search
2018-425-E AMS - Sasser Companies Annex upfit
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-425-E AMS - Sasser Companies Annex upfit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2018 1:51:04 PM
Creation date
8/24/2018 9:08:20 AM
Metadata
Fields
Template:
Contract
Date
8/7/2018
Contract Starting Date
8/7/2018
Contract Ending Date
9/7/2018
Contract Document Type
Agreement - Construction
Amount
$390,849.00
Document Relationships
R 2018-425 AMS - Sasser Companies BOE upfit
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 239500 — MULTI - INDOOR VRV SYSTEM <br />9. Oil Return Heating — Multiple condenser VRV systems shall maintain continuous heating <br />during oil return operation. Reverse cycle (cooling mode) oil return during heating opera- <br />tion shall not be permitted due to the potential reduction in space temperature. <br />10. Low Ambient Cooling - Each system shall be capable of low ambient cooling operation to <br />-4 °F DB (- 20 °CDB). <br />11. Independent Control - Each indoor unit shall use a dedicated electronic expansion valve <br />for independent control. <br />12. Flexible Design — <br />a. Systems shall be capable of up to 540ft (165m) [623 ft. (190m) equivalent] of linear <br />piping between the condensing unit and furthest located indoor unit. <br />b. Systems shall be capable of up to 3,280ft (1,000m) total 'one -way" piping in the pip- <br />ing network. <br />c. Systems shall have a vertical (height) separation of up to 295ft between the condens- <br />ing unit and the indoor units. <br />d. Systems shall be capable of up to 295ft (90m) from the first REFNETT" / branch point. <br />e. The condensing unit shall have the ability to connect an indoor unit evaporator ca- <br />pacity of up to 200% of the condensing unit nominal capacity. <br />f. Systems shall be capable of 98ft (30m) vertical separation between indoor units. <br />g. Condensing units shall be supported with a fan motor ESP up to 0.32" WG as stand- <br />ard to allow connection of discharge ductwork and to prevent discharge air short cir- <br />cuiting. <br />13. Oil return — Each system shall be furnished with a centrifugal oil separator and active oil <br />recovery cycle. <br />14. Simple wiring — Systems shall use 16/18 AWG, 2 wire, stranded, non - shielded and non - <br />polarized daisy chain control wiring. <br />15. Outside Air — Systems shall provide outside air capability. <br />16. Space saving — Each system shall have a condensing unit module footprint no larger <br />than 48 -7/8" x 30- 3/16" (1694mm x 1242mm x 767mm). <br />17. Advanced diagnostics — Systems shall include a self- diagnostic, auto -check function to <br />detect a malfunction and display the type and location. <br />18. Each condensing unit shall incorporate contacts for electrical demand shedding with op- <br />tional 3 stage demand control with 12 customizable demand settings. <br />19. Advanced controls — Each system shall have at least one remote controller capable of <br />controlling up to 16 indoor units. <br />Reece, Noland & McElrath, Inc. 239500-17 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.