Browse
Search
2018-425-E AMS - Sasser Companies Annex upfit
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-425-E AMS - Sasser Companies Annex upfit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2018 1:51:04 PM
Creation date
8/24/2018 9:08:20 AM
Metadata
Fields
Template:
Contract
Date
8/7/2018
Contract Starting Date
8/7/2018
Contract Ending Date
9/7/2018
Contract Document Type
Agreement - Construction
Amount
$390,849.00
Document Relationships
R 2018-425 AMS - Sasser Companies BOE upfit
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 239500 - MULTI - INDOOR VRV SYSTEM <br />es, crankcase heaters, fusible plug, overload relay, inverter overload pro- <br />tector, thermal protectors for compressor and fan motors, over current <br />protection for the inverter and anti - recycling timers. <br />10. To ensure the liquid refrigerant does not flash when supplying to the vari- <br />ous indoor units, the circuit shall be provided with a sub - cooling feature. <br />11. Oil recovery cycle shall be automatic occurring 2 hours after start of oper- <br />ation and then every 8 hours of operation <br />12. The condensing unit shall be capable of heating operation at 0 °F dry bulb <br />ambient temperature without additional low ambient controls or an auxilia- <br />ry heat source. <br />Unit Cabinet: <br />1. The condensing unit shall be completely weatherproof and corrosion re- <br />sistant. The unit shall be constructed from rust - proofed mild steel panels <br />coated with a baked enamel finish. <br />C. Fan: <br />1. The condensing unit shall consist of one or more propeller type, direct - <br />drive 350 or 750 W fan motors that have multiple speed operation via a <br />DC (digitally commutating) inverter. <br />Model Number <br />Fan Motor Output W & Quantity <br />RXYQ72TYDN <br />750 x 1 <br />RXYQ96TYDN <br />350 x 2 <br />RXYQ120TYDN <br />350 x 2 <br />RXYQ144TYDN <br />750 x 2 <br />RXYQ168TYDN <br />750 x 2 <br />RXYQ192TYDN <br />350 x 2 + 750 x 1 <br />RXYQ216TYDN <br />350 x 2 + 350 x 2 <br />RXYQ240TYDN <br />350 x 2 + 350 x 2 <br />RXYQ264TYDN <br />350 x 2 + 750 x 2 <br />RXYQ288TYDN <br />750 x 2 + 750 x 2 <br />RXYQ312TYDN <br />750 x 2 + 750 x 2 <br />RXYQ336TYDN <br />750 x 2 + 750 x 2 <br />RXYQ360TYDN <br />350 x 2) + 350 x 2) + 350 x 2 <br />RXYQ384TYDN <br />350 x 2) + 350 x 2) + 750 x 2 <br />RXYQ408TYDN <br />(350 x 2) + (750 x 2) + (750 x 2) <br />The condensing unit fan motor shall have multiple speed operation of the <br />DC (digitally commutating) inverter type, and be of high external static <br />pressure and shall be factory set as standard at 0.12 in. WG. A field set- <br />ting switch to a maximum 0.32 in. WG pressure is available to accommo- <br />date field applied duct for indoor mounting of condensing units. <br />The fan shall be a vertical discharge configuration with a nominal airflow <br />maximum range of 5,544 CFM to 22,283 CFM dependent on model <br />specified. <br />4. Nominal sound pressure levels shall be as shown below. <br />Reece, Noland & McElrath, Inc. 239500-8 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />