Browse
Search
2018-425-E AMS - Sasser Companies Annex upfit
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-425-E AMS - Sasser Companies Annex upfit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2018 1:51:04 PM
Creation date
8/24/2018 9:08:20 AM
Metadata
Fields
Template:
Contract
Date
8/7/2018
Contract Starting Date
8/7/2018
Contract Ending Date
9/7/2018
Contract Document Type
Agreement - Construction
Amount
$390,849.00
Document Relationships
R 2018-425 AMS - Sasser Companies BOE upfit
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 238147 — DEDICATED OUTDOOR AIR SYSTEM <br />a. Off manual <br />b. Auto <br />c. Heat /Cool <br />d. Cool only <br />e. Heat only <br />f. Fan only <br />2. Occupancy mode <br />a. Auto <br />b. Occupied <br />c. Unoccupied <br />d. Tenant override <br />3. Unit operation changeover control <br />a. Return air temperature <br />b. Space temperature <br />c. Network signal <br />4. Cooling and heating change -over temperature with deadband <br />5. Cooling discharge air temperature (DAT) <br />6. Supply reset options <br />a. Return air temperature <br />b. Outdoor air temperature <br />c. Space temperature <br />d. Airflow (VAV) <br />e. Network signal <br />f. External (0 -10 vdc) <br />g. External (0 -20 mA) <br />7. Temperature alarm limits <br />a. High supply air temperature <br />b. Low supply air temperature <br />c. High return air temperature <br />8. Lockout control for compressors. <br />9. Compressor interstage timers <br />10. Night setback and setup space temperature. <br />11. Building static pressure. <br />12. Economizer changeover <br />a. Enthalpy <br />b. Drybulb temperature <br />13. Currently time and date <br />14. Tenant override time <br />15. Occupied /unoccupied time schedule <br />16. One event schedule <br />17. Holiday dates and duration <br />18. Adjustable set points <br />19. Service mode <br />a. Timers normal (all time delays normal) <br />b. Timers fast (all time delays 20 sec) <br />I. If the unit is to be programmed with a night setback or setup function, an optional space sensor <br />shall be provided. Space sensors shall be available to support field selectable features. Sensor op- <br />tions shall include: <br />1. Zone sensor with tenant override switch <br />2. Zone sensor with tenant override switch plus heating and cooling set point adjustment. (Space <br />Comfort Control systems only) <br />Reece, Noland & McElrath, Inc. 238147-8 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />
The URL can be used to link to this page