Browse
Search
2018-425-E AMS - Sasser Companies Annex upfit
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-425-E AMS - Sasser Companies Annex upfit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2018 1:51:04 PM
Creation date
8/24/2018 9:08:20 AM
Metadata
Fields
Template:
Contract
Date
8/7/2018
Contract Starting Date
8/7/2018
Contract Ending Date
9/7/2018
Contract Document Type
Agreement - Construction
Amount
$390,849.00
Document Relationships
R 2018-425 AMS - Sasser Companies BOE upfit
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 9826C043- 4C32- 49CD- A4CC- DC28ABAB7CE7 <br />SECTION 238147 — DEDICATED OUTDOOR AIR SYSTEM <br />D. Interface control module to new building Energy Management System to be furnished and <br />mounted by rooftop unit manufacturer. Through this interface module, all Energy Management func- <br />tions (specified in Energy Management Section) shall be integrated to the ems and performed <br />through the ems. The interface is to be connected to ems for this project. All points shall be inte- <br />grated to ems to provide full monitoring, setpoint adjustment (temp., economizer, etc.), operating <br />schedule adjustment (on /off), etc. Fully functionality shall be possible via ems or via local control. <br />Provide all ems interface modules, parts, etc. as required for a complete installation. Interface shall <br />be Bacnet compatible. <br />E. All digital inputs and outputs shall be protected against damage from transients or incorrect volt- <br />ages. All field wiring shall be terminated at a separate, clearly marked terminal strip. <br />F. The DDC controller shall have a built -in time schedule. The schedule shall be programmable from <br />the unit keypad interface. The schedule shall be maintained in nonvolatile memory to insure that it is <br />not lost during a power failure. There shall be one start /stop per day and a separate holiday sched- <br />ule. The controller shall accept up to sixteen holidays each with up to a 5 -day duration. Each unit <br />shall also have the ability to accept a time schedule via BAS network communications. <br />G. The keypad interface shall allow convenient navigation and access to all control functions. The <br />unit keypad /display character format shall be 4 lines x 20 characters. All control settings shall be <br />password protected against unauthorized changes. For ease of service, the display format shall be <br />English language readout. Coded formats with look -up tables will not be accepted. The user interac- <br />tion with the display shall provide the following information as a minimum: <br />1. Return air temperature. <br />2. Discharge air temperature. <br />3. Outdoor air temperature. <br />4. Space air temperature. <br />5. Outdoor enthalpy, high /low. <br />6. Compressor suction temperature and pressure <br />7. Compressor head pressure and temperature <br />8. Expansion valve position <br />9. Condenser fan speed <br />10. Inverter compressor speed <br />11. Dirty filter indication. <br />12. Airflow verification. <br />13. Cooling status. <br />14. Control temperature (Changeover). <br />15. VAV box output status. <br />16. Cooling status /capacity. <br />17. Unit status. <br />18. All time schedules. <br />19. Active alarms with time and date. <br />20. Previous alarms with time and date. <br />21. Optimal start <br />22. Supply fan and exhaust fan speed. <br />23. System operating hours. <br />a. Fan <br />b. Exhaust fan <br />c. Cooling <br />d. Inndividual compressor <br />e. Heating <br />f. Economizer <br />g. Tenant override <br />H. The user interaction with the keypad shall provide the following: <br />1. Controls mode <br />Reece, Noland & McElrath, Inc. 238147-7 Orange County Board of Elections <br />Orange Co., NC 05/04/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.