Orange County NC Website
DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 <br />ri 1 <br />0 <br />is <br />C <br />0 <br />E <br />F <br />G <br />W <br />o �o <br />I <br />RII <br />ico <br />C IO <br />U <br />CD t <br />N <br />I <br />O <br />N <br />O <br />I <br />=II <br />N O <br />U <br />�o <br />' N <br />�o <br />9 <br />O <br />I <br />II <br />O o <br />N <br />to <br />■ <br />■ <br />O ■o <br />2 <br />GENERAL ELECTRICAL NOTES <br />3 <br />1. THIS CONTRACTOR SHALL COORDINATE WITH ALL OTHER CONTRACTORS AND TRADES TO LOCATE HIS WORK TO AVOID CONFLICTS. <br />2. THIS CONTRACTOR SHALL NOT UTILIZE "THRU TYPE OUTLET BOXES WHERE DEVICES ARE SHOWN BACK TO BACK IN SOUND <br />INSULATED OR SOUND SECURE AREAS, TYPICAL. <br />3. SMOKE DETECTORS FOR AIR HANDLING UNITS SHALL BE LOCATED IN AIR DUCTS OBSERVING ALL APPLICABLE CODES AND <br />ORDINANCES. ELECTRICAL CONTRACTOR SHALL COORDINATE THE EXACT LOCATION AND REQUIREMENTS OF INSTALLATION WITH <br />MECHANICAL CONTRACTOR PRIOR TO CUTTING DUCTWORK. LOCATE THE DETECTOR INDICATOR /RESET DEVICE IN AN ACCESSIBLE <br />LOCATION AS DIRECTED BY THE ARCHITECT AND LABEL AS TO AREA AND ROOFTOP UNIT SERVED, TYPICAL. <br />4. MOUNTING HEIGHTS GIVEN ARE TO TOP OF OUTLET BOX, UNLESS OTHERWISE NOTED. HEIGHTS MAY BE ADJUSTED TO MATCH <br />MASONRY JOINTS, AND MUST COMPLY WITH NORTH CAROLINA STATE BUILDING CODE VOLUME 1 -C. <br />5. ALL CONDUITS AND RACEWAYS ARE TO BE CONCEALED UNLESS OTHERWISE NOTED OR APPROVED BY THE DESIGNER. <br />6. ALL CONDUITS, SLEEVES, INSERTS, OUTLET BOXES, AND OTHER ROUGH -IN MATERIALS SHALL BE INSTALLED AS BUILDING <br />CONSTRUCTION PROGRESSES. <br />7. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br />8. IN RECEIVING AND OTHER AREAS WHERE ITEMS SUCH AS EXIT SIGN, FIRE ALARM DEVICES, ETC., ARE SUBJECT TO DAMAGE, PROVIDE <br />AND INSTALL GUARDS AS RECOMMENDED BY THE MANUFACTURER. <br />9. THE SYMBOL " " DENOTED GROUNDING CONDUCTOR, TYPICAL UNLESS OTHERWISE NOTED, ALL CONDUITS SHALL BE 3/4" MINIMUM. <br />10. ALL PANEL DIRECTORIES SHALL BE TYPED AS TO THE LOAD SERVED AND USING THE OWNER'S NUMBERING SYSTEM. <br />11. ALL WIRING TROUGHS SHALL BE A MINIMUM OF 8" DEEP. <br />12. ALL ELECTRICAL PANELS TO BE LABELED WITH PHENOLIC LABELS. <br />GENERAL NOTES FOR ELECTRICAL DEMOLITION <br />1. LIGHTING, POWER, DATA, INTERCOM, SECURITY - CONTRACTOR MAY REUSE EXISTING CONDUIT & WIRING TO THE EXTENT <br />POSSIBLE IN PROVIDING A COMPLETE & OPERABLE SYSTEM. CONTRACTOR IS TO PROVIDE ALL LABOR & MATERIALS, INCLUDING <br />BUT NOT LIMITED TO DEVICES, BOXES, CONDUIT, & WIRING FROM ALL DEVICES TO APPROPRIATE DISTRIBUTION /CONTROL <br />PANEL IN ORDER TO PROVIDE A COMPLETE & OPERABLE SYSTEM. CONTRACTOR TO FIELD VERIFY ALL EXISTING QUANTITIES & <br />LOCATIONS & COORDINATE CLOSELY WITH OWNER. <br />2. E.C. TO TAKE CARE IN REMOVING, TAGGING, & STORING DEVICES DURING DEMO PHASE, & REPLACING DEVICES TO BE REUSED <br />DURING NEW CONSTRUCTION PHASE. EXISTING CEILING MOUNTED DEVICES TO BE REINSTALLED AS CLOSE AS POSSIBLE TO <br />ORIGINAL LOCATION. PROVIDE MATERIAL & LABOR FOR EXTENDING CONDUIT & WIRING, AS REQUIRED, FOR REINSTALLATION. <br />ENSURE PROPER OPERATION AFTER CONSTRUCTION. <br />3, WHERE RECEPTACLES ARE REMOVED, ELECTRICAL CONTRACTOR TO REMOVE EXISTING RECEPTACLE DEVICE, BOX, CONDUIT & <br />WIRING BACK TO IT'S SOURCE. WHERE CIRCUIT FEEDING RECEPTACLE TO BE REMOVED ALSO FEEDS RECEPTACLES THAT ARE <br />TO REMAIN, ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT, WIRING & BOXES AS REQUIRED TO RE -FEED EXISTING <br />RECEPTACLES, AS REQUIRED, FOR PROPER OPERATION. <br />EXISTING BUILDING NOTES <br />1. WHERE NOTED, REMOVE ALL CONDUIT, WIRING, & ELECTRICAL EQUIPMENT, <br />INCLUDING PREVIOUSLY ABANDONED, RENDERED USELESS BY CONSTRUCTION. <br />2. ALL MATERIALS REMOVED & NOT TO BE REUSED ARE TO BE DISPOSED OF PER <br />OWNER'S INSTRUCTIONS. <br />3. EXISTING WIRING & RACEWAYS TO BE REUSED WHERE POSSIBLE OR PRACTICAL, & <br />EXISTING WIRING IS FOUND TO BE IN GOOD CONDITION; REPLACE ANY EXISTING <br />WIRING FOUND TO BE IN POOR CONDITION. ALL NEW INSTALLATIONS SHALL USE NEW <br />WIRE, TYPICAL. <br />4. EXISTING WIRING, DEVICES, ELECTRICAL PANELS, ETC. ARE SHOWN LIGHTER & <br />DASHED. <br />4 1 5 <br />ELECTRICAL SPECIFICATIONS <br />IT IS THE INTENT OF THESE SPECIFICATION FOR THE ELECTRICAL CONTRACTOR TO FURNISH A COMPLETE ELECTRICAL <br />SYSTEM, FULLY ADJUSTED, & READY FOR USE. <br />ALL ELECTRICAL WORK TO BE DONE IN STRICT ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL <br />CODE OBSERVING ALL STATE AND LOCAL CODES. <br />ELECTRICAL CONTRACTOR SHALL GIVE ALL NECESSARY NOTICES, OBTAIN ALL PERMITS & PAY ALL SALES TAXES, UTILITY <br />COMPANY CHARGES FOR SERVICE, PERMITS, FEES, & OTHER COSTS IN CONNECTION WITH HIS WORK. <br />ELECTRICAL CONTRACTOR TO ENSURE THAT ALL MATERIAL & EQUIPMENT FURNISHED FOR THIS PROJECT SHALL BE U.L. <br />LISTED. <br />THE MATERIAL & EQUIPMENT HAS BEEN CAREFULLY SELECTED FOR THIS PROJECT & THE ELECTRICAL CONTRACTOR IS <br />EXPECTED TO PROVIDE ALL ITEMS AS CLOSELY AS POSSIBLE TO THE SPECIFICATIONS & AS CALLED FOR ON THE DRAWINGS. <br />ELECTRICAL CONTRACTOR SHALL SUBMIT THREE (3) SETS OF EQUIPMENT DATA SHOP DRAWINGS TO THE ENGINEER FOR ALL <br />ITEMS TO BE FURNISHED & INSTALLED FOR APPROVAL. <br />ELECTRICAL CONTRACTOR SHALL INCLUDE IN THE WORK WITHOUT EXTRA COST TO THE OWNER ANY LABOR MATERIALS <br />SERVICES, APPARATUS, DRAWINGS, INCIDENTAL CONSTRUCTION WORK, ETC., IN ORDER TO COMPLY WITH ALL APPLICABLE <br />LAWS, ORDINANCES, & REGULATIONS, WHETHER. OR NOT SHOWN ON DRAWINGS AND /OR SPECIFIED. NO CLAIM FOR EXTRAS <br />WILL BE APPROVED WITHOUT PRIOR COORDINATION FOR CONFLICTS BY CONTRACTOR, & WRITTEN REQUEST & APPROVAL <br />PRIOR TO PERFORMING WORK. <br />ALL WORK & EQUIPMENT TO BE GUARANTEED BY CONTRACTOR FOR ONE (1) YEAR. <br />UPON COMPLETION OF ALL WORK & ALL TESTS, ELECTRICAL CONTRACTOR SHALL INSTRUCT THE OWNER OR HIS <br />REPRESENTATIVE FULLY IN THE OPERATIONS, ADJUSTMENTS, & MAINTENANCE OF EQUIPMENT FURNISHED. ELECTRICAL <br />CONTRACTOR SHALL PROVIDE OWNER WITH MAINTENANCE SCHEDULE FOR THE PRINCIPAL ITEMS OF EQUIPMENT <br />FURNISHED. MANUFACTURER'S ADVERTISING LITERATURE OR CATALOGS WILL NOT BE ACCEPTABLE. <br />ALL MATERIALS & EQUIPMENT TO BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS & GOOD RECOMMENDED PRACTICES. <br />ELECTRICAL CONTRACTOR SHALL GIVE FULL COOPERATION TO OTHER TRADES. WHERE THE WORK OF ELECTRICAL <br />CONTRACTOR WILL BE INSTALLED IN CLOSE PROXIMITY TO, OR WILL INTERFERE WITH WORK OF OTHER TRADES, HE SHALL <br />ASSIST IN WORKING OUT SPACE CONDITIONS TO MAKE SATISFACTORY ADJUSTMENTS. IF ELECTRICAL CONTRACTOR <br />INSTALLS HIS WORK BEFORE COORDINATING WITH OTHER. TRADES, HE SHALL MAKE THE NECESSARY CHANGES IN HIS WORK <br />TO CORRECT THE CONDITION WITHOUT EXTRA CHARGE. <br />THE DRAWINGS ARE DIAGRAMMATIC & INDICATE THE GENERAL ARRANGEMENTS OF SYSTEMS & WORK INCLUDED IN THE <br />CONTRACT. THE DRAWINGS ARE NOT TO BE SCALED. <br />ELECTRICAL CONTRACTOR TO VERIFY EXACT LOCATION OF EQUIPMENT, ROUTING PIPE, ETC., & WORK CLOSELY WITH OTHER <br />TRADES TO AVOID CONFLICTS. <br />ELECTRICAL CONTRACTOR TO LOCATE & INSTALL ELECTRICAL CONTROL PANELS IN SUITABLE LOCATION WITH APPROPRIATE <br />CLEARANCES & OVERLOAD PROTECTION FOR ALL ITEMS REQUIRED. <br />ELECTRICAL CONTRACTOR MAY COMBINE CONDUITS WHERE APPLICABLE, BUT MUST HOOK UP ITEMS TO PROPER CIRCUITS <br />AS SHOWN. <br />THE OWNER., ARCHITECT & ELECTRICAL CONTRACTOR TO COORDINATE FOR PROPER CUTOUT HOLES, ALL STUB -UPS & <br />JUNCTION BOXES, & TO VERIFY LOCATIONS. <br />ALL CONDUCTORS TO BE COPPER WITH TYPE THHW OR XHHW INSULATION UNLESS OTHERWISE NOTED. <br />WHERE ALUMINUM CONDUCTORS ARE UTILIZED THEY SHALL BE TERMINATED WITH BURNDY HY -PLUG, HYDRAULIC <br />COMPRESSION TERMINATORS. <br />EXTERIOR MOUNTED BOXES SHALL HAVE APPROVED WEATHERPROOF PLATES &/OR COVERS. <br />ALL SURFACE INSTALLED BOXES SHALL HAVE NYLON DEVICE PLATES. <br />ALL DEVICE OUTLETS SHALL BE FLUSH MOUNTED UNLESS SPECIFICALLY NOTED. <br />ALL FIXED ELECTRICAL EQUIPMENT INCLUDING RECEPTACLES SHALL BE LABELED WITH A REFERENCE TO THE CIRCUIT & <br />PANEL OF ORIGIN. ALL PANELS SHALL BE LABELED WITH PANEL NAME & SOURCE OF SUPPLY. ALL PANEL DIRECTORIES SHALL <br />USE ROOM IDENTIFICATIONS TO BE SUPPLIED BY THE OWNER, NOT THE ROOM NAMES & NUMBERS ON THE DRAWINGS. <br />ALL LABELS REFERRING TO EMERGENCY POWER SHALL BE PER FACILITIES CURRENT COLOR CODE. <br />CONDUIT, WIRING, & ELECTRICAL EQUIPMENT & DEVICES CAUSED TO BE ABANDONED OR RENDERED USELESS BY <br />CONSTRUCTION SHALL BE REMOVED BACK TO THE SOURCE. IN ADDITION, CONDUIT, WIRING, ELECTRICAL EQUIPMENT & <br />DEVICES DISCOVERED ABANDONED WITHIN THE LIMITS OF CONSTRUCTION SHALL BE REMOVED BACK TO THE SOURCE, EVEN <br />IF THIS SHOULD INVOLVE REMOVAL OUTSIDE THE LIMITS OF CONSTRUCTION. <br />SUPPLEMENTAL ELECTRICAL SPECIFICATIONS <br />ALL PENETRATIONS OF RATED PARTITIONS, FLOOR SLABS BY EITHER NEW OR EXISTING CONDUITS SHALL BE FIRE CAULKED <br />OR CLOSED BY APPROVED U.L. METHODS BY THE ELECTRICAL CONTRACTOR. <br />ELECTRICAL CONTRACTOR TO MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS WITH AS -BUILT CONDITIONS & <br />TURN OVER TO THE OWNER. <br />ALL No. 10 & No. 12 CONDUCTORS FOR RECEPTACLES & LIGHTING CIRCUITS SHALL BE STRANDED COPPER. <br />ALL TERMINATIONS SHALL BE NUMBERED AND LABELED. <br />ALL CONDUCTORS SHALL BE MARKED WITH CIRCUIT NUMBER WHEN TERMINATING AT THE PANELBOARD. <br />ALL 15A, 20A, & 30 AMPERE HOME RUN CONDUCTORS EXCEEDING 150' SHALL BE INCREASED ONE WIRE SIZE TO COMPENSATE <br />FOR VOLTAGE DROP. ADJUST CONDUIT SIZE ACCORDINGLY. <br />ALL CONDUIT COUPLINGS AND CONNECTORS SHALL BE "T &B" INSULATED THROAT COMPRESSION TYPE. NO "INDENTER" OR <br />SET SCREW DEVICES WILL BE ALLOWED, TYPICAL. <br />ALL PENETRATIONS THROUGH FLOOR SLAB OR RATED ASSEMBLIES SHALL BE APPROVED BY THE OWNER, ARCHITECT & <br />STRUCTURAL ENGINEER PRIOR TO CUTTING OR BORING. ALL PENETRATIONS SHALL BE SLEEVED, FIRE CAULKED & FINISHED <br />WITH COLLAR ON BOTH SIDES. ANY PENETRATION NOT COORDINATED WILL RESULT IN CONTRACTOR BEARING ALL COSTS <br />ASSOCIATED WITH PATCHING, REPAIRING & REFINISHING AREA TO THE SATISFACTION OF THE OWNER & ENGINEER. <br />ALL ELECTRICAL "TIE -INS" & "SHUT- DOWNS" SHALL BE COORDINATED WITH THE OWNER PRIOR TO COMMENCEMENT OF <br />WORK. CONTRACTOR SHALL NOTIFY OWNER A MINIMUM OF 72 HOURS PRIOR TO ANY SUCH WORK. <br />ALL EXISTING EQUIPMENT, CONDUIT, WIRING, BOXES ETC. RENDERED UNUSED, SHALL BE REMOVED & DISPOSED OF AS <br />DIRECTED BY THE OWNER. <br />0 <br />7 <br />ELECTRICAL SYMBOL SCHEDULE <br />Duct - Mounted Smoke Detector. Match existing. Connect to <br />SD D existing Fire Alarm system. <br />ABBREVIATIONS <br />ACT ..............ABOVE <br />NOTE: EXISTING DEVICES SHOWN LIGHTER AND WITH DASHED LINES. <br />ATS ..............AUTOMATIC <br />ALL SYMBOLS MAY NOT BE USED <br />AFF ..............ABOVE <br />FINISHED FLOOR <br />SEE SPECIFICATIONS FOR A COMPLETE LISTING OF MFG'S <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />S <br />Switch, single pole, 20 amp, commercial duty, Bryant #4901 <br />Leviton #1221 120/277 <br />4' -0" AFF t Top <br />SEALS: <br />or volt rated. <br />or as noted <br />EWC .............ELECTRIC <br />Receptacle, industrial grade, duplex, Bryant #5252 <br />EWH .............ELECTRIC <br />WALL HEATER <br />Leviton #5252, 15 ampere rated, grounding type, <br />1' -6" AFF <br />GC ...............GENERAL <br />2 pole, 3 wire, 125 volts. <br />GWH .............GAS <br />WALL HEATER <br />Receptacle, same as above except mounting height. <br />0' -6" ACT or <br />as noted <br />MCCB ........... <br />Double Duplex Receptacle, (2) Bryant #5252 or <br />1' -6" AFF <br />-FUSED DISCONNECT SWITCH <br />(2) Leviton #5252, 15 ampere rated, grounding type. <br />unless noted <br />RTU ..............ROOFTOP <br />Receptacle, same as above except mounting height. <br />0' -6" ACT or as noted <br />UNDERGROUND <br />Ground fault circuit interrupting receptacle, 15 amp, <br />1' -6" AFF <br />XFMR ........... <br />feed -thru type, standard duty, Bryant #GFR52FT. <br />®z O <br />m ww o <br />Receptacle, same as above except mounting height. <br />0' -6" ACT or <br />as noted <br />VVP <br />Receptacle, same as above with Weather Proof cover. <br />V-6" n or <br />as <br />as noted <br />0c) <br />Receptacle, industrial grade, duplex, Bryant #5362 <br />:1&20A <br />Leviton #5362, 20 ampere rated, grounding type, <br />1'4' AFF <br />2 pole, 3 wire, 125 volts. <br />U OW <br />-Cr-20A <br />Receptacle, same as above except mounting height. <br />0' -6" ACT or <br />as noted <br />30A <br />Receptacle, Locking, 125 volt rated, 30 amp, 2 pole, 3 wire, <br />1' -6" AFF <br />Bryant #70530 -FR with mating plug and cord. <br />as noted <br />30A <br />Receptacle, 250 volt rated, 30 amp, 3 pole, 4 wire, <br />1' -6" AFF <br />Bryant #9430 -FR with mating plug and cord. <br />as noted <br />New conduit/wiring <br />- - - -- <br />Home run to panelboard. Arrowheads indicate number of <br />As Required <br />circuits. <br />7 <br />Disconnect switch, 600V. Where exposed to weather shall <br />As Required, <br />be NEMA 3R. Square " T safety switch or equal. <br />no higher than <br />ELECTRICAL SYMBOLS, <br />SPECIFICATIONS & <br />6' -6" AFF <br />■ <br />Junction box (JB) as manufactured by RACO, Steel City, or <br />As required <br />JWC <br />Universal. Size as applicable or required. <br />APPROVED BY: I <br />Fs-s <br />Surge Suppresser <br />Mnt, on Service <br />E1.0 <br />See specifications. <br />Distribution Eq. <br />Electrical panelboard, see panel schedule for description. <br />6-6" to top <br />Duct - Mounted Smoke Detector. Match existing. Connect to <br />SD D existing Fire Alarm system. <br />ABBREVIATIONS <br />ACT ..............ABOVE <br />COUNTER TOP <br />ATS ..............AUTOMATIC <br />TRANSFER SWITCH <br />AFF ..............ABOVE <br />FINISHED FLOOR <br />AHU .............AIR <br />HANDLER UNIT <br />AFG ..............ABOVE <br />FINISHED GRADE <br />BCT ..............BELOW <br />COUNTER TOP <br />CLG ..............CEILING <br />SEALS: <br />EC ................ELECTRICAL <br />CONTRACTOR <br />EWC .............ELECTRIC <br />WATER COOLER <br />EWH .............ELECTRIC <br />WALL HEATER <br />FDS ..............FUSED <br />DISCONNECT SWITCH <br />GC ...............GENERAL <br />CONTRACTOR <br />GWH .............GAS <br />WALL HEATER <br />MC ...............MECHANICAL <br />CONTRACTOR <br />MCCB ........... <br />MOLDED CASE CIRCUIT BREAKER <br />NFD .............NON <br />-FUSED DISCONNECT SWITCH <br />PC ............... <br />PLUMBING CONTRACTOR <br />RTU ..............ROOFTOP <br />UNIT <br />UG ............... <br />UNDERGROUND <br />WCP .............WATER <br />CIRCULATION PUMP <br />XFMR ........... <br />TRANSFORMER <br />f <br />1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 <br />11 <br />1.1 <br />C <br />I <br />E <br />F <br />G <br />2 <br />RK14 <br />MILSICISILILUS <br />Reece, Noland & McElrath, Inc. <br />94 Main Street <br />Canton, North Carolina 28716 <br />PHONE: 828 - 492 -0677 <br />FAX: 828 - 492 -1054 <br />MAIL@RNM- ENGMEERS.COM <br />WW W.RNM- ENGINEERS.COM <br />NC CERT. N0. C -0149 <br />(D 2018 <br />SEALS: <br />M Z LZ J <br />O of <br />Z <br />}lllil9lf+JJ <br />��� °4 CA,RO, /�Ji <br />oOf aUjz <br />Z(nU�O <br />cn 0 0 Uj <br />— U W� U <br />c� = z <br />cnw <br />_ EAL _ <br />v c — <br />�y /fC'ry ° <br />QONOw <br />Of M <br />p <br />rf�✓} <br />J 0 v <br />N v G` o <br />❑ r�'� <br />��Q_ <br />C/) <br />Z <br />O <br />U <br />W Z <br />O <br />W� <br />LL <br />U <br />00, <br />0 _ z <br />LU <br />r _ <br />D <br />®z O <br />m ww o <br />G m <br />J <br />Z J <br />z0 <br />LU <br />0c) <br />U � <br />W = <br />V <br />Z <br />U OW <br />0 <br />W <br />Q_ <br />REVISIONS /SUBMISSIONS <br />NO <br />DATE <br />ISSUED FOR <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />SHEET TITLE: <br />ELECTRICAL SYMBOLS, <br />SPECIFICATIONS & <br />NOTES <br />ISSUED FOR: <br />CONSTRUCTION <br />DRAWN BY: <br />JWC <br />DRAWING NO. <br />APPROVED BY: I <br />JSD <br />PROJECT #: <br />2017108 <br />E1.0 <br />DATE: <br />05/07/2018 <br />OF 2 SHEETS <br />