Browse
Search
2018-347-E AMS - Hoffman and Hoffman HVAC Annex
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-347-E AMS - Hoffman and Hoffman HVAC Annex
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2018 10:40:27 AM
Creation date
8/7/2018 3:43:27 PM
Metadata
Fields
Template:
Contract
Date
7/31/2018
Contract Starting Date
7/31/2018
Contract Document Type
Agreement - Construction
Amount
$65,772.00
Document Relationships
R 2018-347 AMS - Hoffman and Hoffman HVAC BOE
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 <br />A <br />I <br />C <br />11 <br />E <br />F <br />G <br />H <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />a <br />WWW.RNM- ENGINEERS.COM <br />NC CERT. N0. C -0149 <br />(C 2018 <br />SEALS: <br />m Z W J <br />O = � <br />}} }}i]If7f1l <br />14j�\ C A <br />��JW <br />:z (n <br />cno OW <br />— 0uiU-0 <br />SEAL <br />4 "0 0/A DOWN <br />0 0 <br />= V) <br />TO IU -1 -17 <br />=11 <br />z <br />O <br />F_ <br />U <br />uw z <br />0 <br />W F_ <br />LL Q <br />� <br />00. <br />C <br />Lu <br />Im <br />Oz 0 <br />m W 0 <br />75 m <br />J <br />J <br />z <br />Cn <br />O c) <br />U � <br />W = <br />V <br />z <br />U <br />2 I <br />U OW <br />C) <br />0 <br />REVISIONS /SU BM ISSIONS <br />NO <br />DATE <br />ISSUED FOR <br />1 <br />"0 <br />"0 <br />c� <br />6 0/A DOWN <br />4 <br />4 0/A DOWN <br />5 <br />TO I U -1 -01 <br />TO I U -1 -18 <br />7 <br />8 <br />SHEET TITLE: <br />ATTIC LEVEL <br />MECHANICAL PLAN <br />I <br />O <br />CONSTRUCTION <br />DRAWN BY: <br />DJM <br />P <br />zo <br />APPROVED BY: <br />MRM <br />PROJECT #: <br />2017108 <br />zo <br />DATE: <br />05/07/2018 <br />TYPICAL BALANCE DAMPER. <br />OF 8 SHEETS <br />REFER TO OUTSIDE AIR <br />SCHEDULE FOR VALUES. <br />l J <br />r <br />� <br />C <br />6 "0 <br />N 4" A DOWN <br />0 <br />i <br />o TO IU -1 -19 <br />all <br />6 "0 0/A DOWN <br />O/A INTAKE LOUVER - APPROX. 4'x6'. M.C. TO REMOVE <br />10' S/A DOWN TO CEILING <br />a <br />TO IU -1 -02 <br />EXISTING WINDOW COMPLETELY, REPLACE WITH <br />SUPPLY DIFUSERS TYPICAL BALANCE DAMPER. <br />LOUVER, AND SEAL WEATHER- TIGHT. COORDINATE <br />REFER TO OUTSIDE AI <br />TO MATCH EXISTING WINDOW DIMENSIONS, <br />SCHEDULE FOR VALUES. <br />N O <br />V <br />m <br />' a <br />TRANSITION DUCTWORK TO FULL <br />SIZE OF LOUVER (TYPICAL). <br />�0 <br />4 "0 O/A DOWN <br />N TO I U -1 -20 <br />zo <br />x <br />10 "0 <br />1 0x1 0 E/A DOWN <br />TYPICAL CONCEALED <br />_ <br />TO FIRST FLOOR <br />TRANSITION DUCTWORK TO UNIT (TYPICAL). 10' S/A DOWN TO CEILING <br />SUPPLY DIFUSERS <br />DUCTED UNIT <br />o <br />I <br />DOAS UNIT SUSPENDED IN ATTIC. <br />=II <br />w o <br />a <br />o <br />IU -2 -01 <br />m m <br />Uo U o <br />16x16 R/A DOWN <br />CEILING GRILLE IU -1 16 <br />0/A DOWN <br />14"0 <br />o <br />TO IU-1-21 <br />N 1 0 <br />v <br />o <br />IU -1 <br />24x10 <br />15 0 <br />10x12 16x12 <br />SD N <br />• <br />SD <br />C C <br />"0 <br />8"0 <br />12 "10,10 <br />12"0 <br />AIR DUCTED <br />6 <br />"0 <br />8 "0 <br />10 � P <br />6 0/A DOWN <br />TO IU -1 -03 <br />TO INDOOR UNITS. <br />8.10 <br />4 "0 O/A DOWN <br />TO I U -1 -27 <br />6x6 E/A DOWN TO <br />4 "0 0/A DOWN <br />FIRST FLOOR <br />TO IU -1 -22 <br />12x12 E/A DOWN UP TO EF -1 ON ROOF. 1 <br />12x12 E/A DOWN UP TO EF -2 ON ROOF. <br />co <br />C co 16x16 R/A DOWN <br />NEW FAN TO REPLACE EXISTING. <br />NEW FAN TO REPLACE EXISTING. <br />CEILING GRILLE <br />COORDINATE WITH EXISTING CONDITIONS. <br />COORDINATE WITH EXISTING CONDITIONS. <br />10x10 <br />OUTSIDE AIR DUCTED <br />TO INDOOR UNITS. <br />8x8 E/A DOWN <br />TO FIRST FLOOR co <br />OUTDOOR UNITS ON FLAT SECTION OF ROOF. OU 1 \ <br />M.0 TO BE RESPONSIBLE FOR REMOVING o <br />DN <br />60 <br />EXISTING CONDENSING UNITS TO MAKE ROOM <br />ox <br />FOR NEW OUTDOOR UNITS. MODIFY EXISTING L _ J <br />OR ADD NEW EQUIPMENT SUPPORTS BY <br />PORTABLE PIPE HANGERS AND SUPPORTS. <br />/A DOWN <br />OU -2 �/ �� <br />TO 10 <br />C <br />6" O/A DOWN TO FIR <br />3T FLOOR 4 "0 0/A DOWN <br />1 0x1 0 E/A DOWN <br />TO IU -1 -26 <br />TO FIRST FLOOR <br />C 6 "0 <br />P <br />60 <br />6 "0 O/A DOWN <br />TO I U -1 -04 <br />C <br />6 "0 <br />4"0 DOWN <br />TO I U-1 -24 <br />U -1 <br />6" O/A DOWN TO <br />P FIRST FLOOR <br />c <br />U <br />6 "0 O/A DOWN <br />6 "0 O/A DOWN <br />TO IU -1 -25 <br />TO I U -1 -05 <br />ATTIC LEVEL MECHANICAL PLAN <br />z <br />SCALE: 1/4" = V -0" <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />A <br />0 <br />C <br />N <br />C <br />F <br />G <br />H <br />R Kli <br />=ENGINEERS <br />Reece, Noland & McElrath, Inc. <br />94 Main Street <br />Canton, North Carolina 28716 <br />PHONE: 828 - 492 -0677 <br />FAX: 828 - 492 -1054 <br />MAIL @RNM - ENGINEERS. COM <br />WWW.RNM- ENGINEERS.COM <br />NC CERT. N0. C -0149 <br />(C 2018 <br />SEALS: <br />m Z W J <br />O = � <br />}} }}i]If7f1l <br />14j�\ C A <br />��JW <br />:z (n <br />cno OW <br />— 0uiU-0 <br />SEAL <br />Z(r�Nw <br />Lo' Ewd <br />Of Q N� W <br />ui <br />= V) <br />U) <br />z <br />O <br />F_ <br />U <br />uw z <br />0 <br />W F_ <br />LL Q <br />� <br />00. <br />Q _j Z <br />Lu <br />D <br />Oz 0 <br />m W 0 <br />75 m <br />J <br />J <br />z <br />W <br />O c) <br />U � <br />W = <br />V <br />z <br />U OW <br />C) <br />0 <br />REVISIONS /SU BM ISSIONS <br />NO <br />DATE <br />ISSUED FOR <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />SHEET TITLE: <br />ATTIC LEVEL <br />MECHANICAL PLAN <br />ISSUED FOR: <br />CONSTRUCTION <br />DRAWN BY: <br />DJM <br />DRAWING NO. <br />APPROVED BY: <br />MRM <br />PROJECT #: <br />2017108 <br />M1.2 <br />DATE: <br />05/07/2018 <br />OF 8 SHEETS <br />
The URL can be used to link to this page
Your browser does not support the video tag.