Orange County NC Website
DocuSign Envelope ID: 72E7BD50- E5C5- 4BEA- B4AA- FCA907469BF8 <br />MOVE FENCE OR <br />REMOVE TREE IF <br />MORE THAN 20% <br />OF A TREE'S MOVE FENCE OR <br />CRITICAL ROOT REMOVE TREE <br />ZONE IS <br />UNPROTECTED <br />TREE _ <br />PROTECTION . <br />FENCE TE ED A 1/ <br />... - - - - -_ / III <br />SCI lyoic Rl� L �Jl��f <br />- I ! <br />CONSTRUCTION AREA <br />'X RETAIN <br />z 10' MAX. <br />METAL OR <br />WOOD POSTS <br />TREE PROTECTION FENCING <br />SCALE: N.T.S. <br />MATCH EXISTING <br />PAVEMENT SECTION <br />2" S9.5B SURFACE 4" B25 -B BINDER <br />COURSE COURSE <br />TRENCH WIDTH 1' -0" <br />(MIN.) (MIN.) <br />TACK COAT <br />SAW CUT <br />PAVEMENT <br />EDGE <br />EXIST. <br />PAVEMENT <br />SCALE: N.T.S. 0000 /DIV- 02/02520A27.DWG <br />BACKFLOW ASSEMBLY MUST <br />BE USC- FCCCHR & ASSE APPROVED MUST BE OUTSIDE STEM AND <br />(DETECTOR ASSY. FOR FIRE LINE INSTALLATIONS) I� YOKE RESILIENT SEAT GATE <br />Jj VALVES FOR FIRE LINE. <br />INSTALLATIONS <br />LINE MUST BE _\ <br />UNBRANCHED AND <br />UNOBSTRUCTED <br />FLOW <br />D.I.P. ON <br />INSTALLATIONS SEE <br />GREATER THAN 3" SE 12 NOTE 1 <br />(COPPER IF t= 3 ") NOTE 3 CLEARANCE <br />MIN. <br />f GRADE <br />r �f8 <br />I MIN. <br />CONCRETE PAD <br />PLASTIC SHEET <br />THRUST BLOCK OR <br />METER TO BE LOCATED RESTRAINED JOINT AND RODDED <br />THIS SIDE, IN R+W <br />NOTES: <br />1. CONCRETE SUPPORT BLOCK REQUIRED ON 2 112` & LARGER BACKFLOW <br />PREVENTERS <br />2. THE DEVICE MUST BE INSTALLED WITH MINIMUM HORIZONTAL <br />CLEARANCES OF 30" FOR SIDE WITH TEST COCKS AND 8" FOR BACK SIDE <br />(NIA WITH REMOVABLE BOX OR PANELS) <br />3. ASSEMBLY IS NOT COMPLETE UNLESS ALL TEST COCKS ARE INSTALLED KPK <br />PER MANUFACTURERS SPECIFICATIONS <br />4. ASSE 106D ENCLOSURE REQUIRED FOR ALL BACKFLOW ASSEMBLIES KPK <br />rev description app'd date <br />10 REDUCED PRESSURE BACKFLOW PREVENTER <br />C4.1/SCALE: N.T.S. <br />A PRE - CONSTRUCTION CONFERENCE MUST <br />BE HELD WITH THE ENGINEER BEFORE ANY <br />SITE WORK BEGINS. A LANDSCAPE <br />PROTECTION SUPERVISOR WHO IS <br />REGISTERED MUST BE PRESENT ON SITE AT <br />ALL TIMES WHEN THE FOLLOWING ACTIVITIES <br />ARE TAKING PLACE: CLEARING, GRUBBING, <br />EXCAVATION, GRADING, TRENCHING, MOVING <br />OF SOIL, INSTALLATION AND REMOVAL OF <br />TREE PROTECTION FENCING, AND THE <br />DELIVERY, TRANSPORTING AND PLACEMENT <br />OF CONSTRUCTION MATERIALS AND <br />EQUIPMENT. <br />TREE PROTECTION NOTES: <br />1. ANY TREE ROOTS EXPOSED BY <br />CONSTRUCTION SHALL BE SEVERED CLEANLY <br />WITH A PRUNING TOOL. <br />2. DO NOT DISPOSE OF ANY CHEMICALS <br />OR REMOVE SOIL OUTSIDE THE AREA OF <br />WORK. <br />3. WHEN INSTALLING NEW LANDSCAPE <br />PLANTS, DO NOT DRIVE EQUIPMENT UPON <br />OR WITHIN THE CRITICAL ROOT ZONE OF <br />EXISTING TREES. <br />CONSTRUCTION SEQUENCE: <br />1. OBTAIN APPROPRIATE PERMITS. <br />2. HOLD PRE - CONSTRUCTION CONFERENCE <br />WITH LANDSCAPE PROTECTION <br />SUPERVISOR, ARCHITECT OR ENGINEER. <br />3. ERECT TREE PROTECTION FENCING. <br />4. CLEAR AND GRUB TREES AND SHRUBS <br />TO BE REMOVED. <br />5. INSTALL SOIL AND EROSION CONTROL <br />MEASURES. <br />6. ROUGH GRADE SITE. <br />7. EXCAVATE FOR FOOTINGS AND INSTALL <br />UTILITIES. <br />8. CONSTRUCT BUILDING. <br />9. FINISH FINAL GRADING AND PAVING. <br />10. REMOVE TREE PROTECTION FENCING. <br />11. INSTALL LANDSCAPING (TO BE SHOWN <br />ON LANDSCAPE PLAN). <br />0000/ D I V -02 /0280OA01. D W G <br />DRAIN@7 %MINIMUM <br />SLOPE TO DAYLIGHT <br />OR STORM DRAINAGE g <br />j DOMESTIC WATER METER VAULT <br />C4 -VSCALE: N.T.S. <br />5-1 A' DRY BARREL HYDRANT, <br />r P.E. X P.E. NIPPLE M1N 6" DIA PIPE <br />� <br />1III <br />"YMEITA IT MIN <br />1X" METER <br />M.J. TEE>� <br />36" <br />PERPENDICULAR TO STREET <br />4" <br />r.f METER IWMIN <br />2" METER <br />R.E. X P.E. <br />LL SS <br />0 MINIMUM 72" FROM EDGE OF CURB <br />NIPPLES <br />T <br />' KETER 2f' MIN <br />p <br />96" <br />60'" <br />` DISTRIBUTION MAIN <br />6" <br />4" METER <br />108" <br />12 <br />- <br />g^ <br />(RESTRAINED JOINTS <br />126" <br />DOMESTIC METER BOX <br />y <br />5" STDRZ CONNECTION <br />GATE VALVE" REURAINEDFLANGEO <br />L7nuTYANCHOR97 <br />1 138" <br />1 78" <br />Z <br />6" <br />ITYPIGALI • UPLING ADAPTER <br />+- <br />)TYPICAL) <br />163'" <br />as <br />60" <br />6" <br />HYDRANT <br />TAMPED VALVE BOX BOTTOM <br />SIDEWALK CURB & <br />BACKFILL <br />FLANGE �,- <br />' '• •GATE ' <br />- <br />F10DR <br />❑ N <br />�► <br />I . <br />SCREW TYPE C <br />CONCRETE SLAB <br />$TAN{3ARpVALVE BO <br />ALL PIPING INTO <br />VAULT SHALL BE <br />TAM PED �-e ,'..'• °.:',• ;. , <br />30# <br />BACKFILL <br />�/ <br />` <br />6" RESILIENT WEDGE <br />FELT <br />z <br />RESTRAINED <br />GATE VALVE <br />n <br />ATER <br />COMPACTED BACKFILL <br />OTHER SIMILAR MODELS ARE AVAILABLE WITH VARIABLE HEIGHT <br />SCREW TYPE VALVE. <br />`O <br />t2" <br />BO %BOTTOM <br />(VARIABLE HEIGHT) <br />RAWER <br />ETER <br />7Y <br />MIN. <br />4. TRAFFIC CASTINGS MUST BE 4,20 WHEEL LOADING RATED <br />MAIN <br />FLOW 1W <br />5. FOR ANY VALVES OVER I Y DEEP, A VALVE STEM EXTENSION MUST BE <br />51 &" BRIDLE SS ROD WI COLLAR <br />USED TO BRING TO A DEPTH OF NO MORE THAN 9, EXTENSION MUST <br />CRUSHED STONE <br />],► N <br />BE A MINIMUM OF V FOR MAINS IT AND LARGER. <br />UNDISTURBED EARTH <br />(REQUIRED) <br />6. TOTAL VALVE SOX WEIGHT: MINIMUM OF 65 LBS. <br />LINK SEAL <br />1 Added ref. to so", appllcaHonc KPK 1110117 <br />MIN. BEARING AREA 18" X 16" <br />KPK <br />HYDRANT LEG <br />NOTES: <br />Qf° <br />OR600r <br />ALL CONCRETE SHALL BE 3000 PSI MIN <br />DISMAN LIN <br />wSMANruN¢ <br />HYDRANTS SHALL BE MANUFACTURED BY CLOW (MEDALLION) OR AVK (SERIES 27 <br />Hrlls " gh <br />NOSTALGIC) AND MEET AW WA 502 STANDARDS ALL HYDRANT VALVES SHALL BE <br />P4 Box 429 <br />CONNECTION <br />101 East Orange Street <br />3. <br />'xRNT <br />Hillsborough, North Carolina 27278 <br />4. <br />HYDRANT FLANGE SHALL BE INSTALLED BETWEEN 2" AND 6" ABOVE SURROUNDING <br />FINAL GRADE <br />•' SEE NOTE 7 <br />5. <br />6. <br />ALL CASTINGS SHALL BE MADE -IN -USA CONFORMING TO ASTM A48 CLASS 356 <br />GRAY CAST IRON <br />a 67 5TONI, <br />SLAM <br />L40 <br />LIFTING <br />LOCATION, WITH A MINIMUM BURY DEPTH OF 3' -6' <br />8. <br />NO MORE THAN ONE HYDRANT EXTENSION SHALL BE ALLOWED AND SHALL NOT' <br />egMESS 0 <br />HANDLE <br />(� II <br />THE MANUFACTURER OF THE HYDRANT INSTALLED <br />(SHOWN <br />�EFNG�' <br />_ <br />_ J <br />❑ <br />A <br />D <br />A <br />BROOM <br />STANDARD VALVE <br />BB 1( <br />FINISH 5 <br />FINISHED GRADE <br />EDGE <br />- <br />--mv, <br />sn. <br />MULTISEAL <br />IN JOI <br />9 <br />a <br />g <br />GATE <br />[LATE <br />VALVE <br />VALVE <br />RIS TRAINS <br />7 <br />ALL PIPING iNTL1 <br />12- 4x4 <br />DISMANTLING <br />4xy 1Y <br />ME VAULT SHALL <br />BE RESTRAINED <br />TRAINER <br />MIN. TEE JOINT <br />' <br />TEE MIN. <br />FLO <br />W ]I► <br />LOOR DRAN <br />WAEBRIS <br />"-' <br />METER I2 IN. <br />SLOPE 20%TO <br />'- <br />MAIN <br />SCREEN <br />7TMINIMUMp67 <br />ST <br />-•.• '. <br />DRAIN@7 %MINIMUM <br />SLOPE TO DAYLIGHT <br />OR STORM DRAINAGE g <br />j DOMESTIC WATER METER VAULT <br />C4 -VSCALE: N.T.S. <br />6 STANDARD FIRE HYDRANT INSTALLATION DETAIL <br />4■ 1 SCALE: N.T.S. 0000 /HILLSBOROUGH /FIRE HYDRANT.DWG <br />TAPPING VALVE <br />5-1 A' DRY BARREL HYDRANT, <br />r P.E. X P.E. NIPPLE M1N 6" DIA PIPE <br />� <br />1III <br />PUMPER NOZZLE TO BE <br />1X" METER <br />M.J. TEE>� <br />36" <br />PERPENDICULAR TO STREET <br />4" <br />((RESTRAINED JOINTS) <br />2" METER <br />R.E. X P.E. <br />LL SS <br />0 MINIMUM 72" FROM EDGE OF CURB <br />NIPPLES <br />T <br />INSERT <br />y* OR IN INSERT TEE <br />p <br />96" <br />60'" <br />` DISTRIBUTION MAIN <br />6" <br />4" METER <br />108" <br />12 <br />48" <br />g^ <br />(RESTRAINED JOINTS <br />126" <br />DOMESTIC METER BOX <br />y <br />5" STDRZ CONNECTION <br />6" <br />8" METER <br />1 138" <br />1 78" <br />Z <br />6" <br />NEPTUNE <br />HP TURBINE <br />10" METER <br />163'" <br />as <br />60" <br />6" <br />HYDRANT <br />TAMPED VALVE BOX BOTTOM <br />SIDEWALK CURB & <br />BACKFILL <br />FLANGE �,- <br />' '• •GATE ' <br />GUTTER <br />PAVEMENT <br />VALVE <br />MAIN <br />SCREW TYPE C <br />CONCRETE SLAB <br />TAM PED �-e ,'..'• °.:',• ;. , <br />30# <br />BACKFILL <br />�/ <br />6" RESILIENT WEDGE <br />FELT <br />z <br />VALVE BOX <br />GATE VALVE <br />n <br />ADJUSTABLE HEIGHT BOX MANUFACTURED BY GENERAL FOUNDRIES. <br />COMPACTED BACKFILL <br />OTHER SIMILAR MODELS ARE AVAILABLE WITH VARIABLE HEIGHT <br />SCREW TYPE VALVE. <br />`O <br />(TAMPED IN 6" LIFTS) <br />BO %BOTTOM <br />(VARIABLE HEIGHT) <br />CONC- THRUST BLOCK <br />$ " MIN. BRANCH PIPE <br />4. TRAFFIC CASTINGS MUST BE 4,20 WHEEL LOADING RATED <br />MAIN <br />5. FOR ANY VALVES OVER I Y DEEP, A VALVE STEM EXTENSION MUST BE <br />51 &" BRIDLE SS ROD WI COLLAR <br />USED TO BRING TO A DEPTH OF NO MORE THAN 9, EXTENSION MUST <br />CRUSHED STONE <br />VARIES <br />BE A MINIMUM OF V FOR MAINS IT AND LARGER. <br />UNDISTURBED EARTH <br />(REQUIRED) <br />6. TOTAL VALVE SOX WEIGHT: MINIMUM OF 65 LBS. <br />GONG. THRUST BLOCKING USE SS RODS <br />1 Added ref. to so", appllcaHonc KPK 1110117 <br />MIN. BEARING AREA 18" X 16" <br />KPK <br />HYDRANT LEG <br />NOTES: <br />Qf° <br />1. <br />ALL CONCRETE SHALL BE 3000 PSI MIN <br />2. <br />HYDRANTS SHALL BE MANUFACTURED BY CLOW (MEDALLION) OR AVK (SERIES 27 <br />Hrlls " gh <br />NOSTALGIC) AND MEET AW WA 502 STANDARDS ALL HYDRANT VALVES SHALL BE <br />P4 Box 429 <br />SECURED TO MAIN LINE BY SS RODS AND BOLTS AND RESTRAINED JOINTS <br />101 East Orange Street <br />3. <br />CONCRETE PAD REQUIRED ON ALL VALVES OUTSIDE OF PAVED AREA <br />Hillsborough, North Carolina 27278 <br />4. <br />HYDRANT FLANGE SHALL BE INSTALLED BETWEEN 2" AND 6" ABOVE SURROUNDING <br />FINAL GRADE <br />919.732.1270 <br />5. <br />SEE TOH SPECIFICATIONS FOR HYDRANT SPACING AND COLOR <br />6. <br />ALL CASTINGS SHALL BE MADE -IN -USA CONFORMING TO ASTM A48 CLASS 356 <br />GRAY CAST IRON <br />7. <br />HYDRANTS SHALL BE ORDERED FOR SPECIFIC BURY DEPTHS OF INTENDED <br />LOCATION, WITH A MINIMUM BURY DEPTH OF 3' -6' <br />8. <br />NO MORE THAN ONE HYDRANT EXTENSION SHALL BE ALLOWED AND SHALL NOT' <br />EXCEED 1 FT. ALL EXTENSIONS MUST BE FROM THE SAME MAKE AND MODEL OF <br />THE MANUFACTURER OF THE HYDRANT INSTALLED <br />6 STANDARD FIRE HYDRANT INSTALLATION DETAIL <br />4■ 1 SCALE: N.T.S. 0000 /HILLSBOROUGH /FIRE HYDRANT.DWG <br />TAPPING VALVE <br />"A" <br />r P.E. X P.E. NIPPLE M1N 6" DIA PIPE <br />� <br />1III <br />WATER <br />METER TYPE <br />1X" METER <br />M.J. TEE>� <br />36" <br />30" <br />4" <br />((RESTRAINED JOINTS) <br />2" METER <br />R.E. X P.E. <br />LL SS <br />30" <br />NIPPLES <br />T <br />INSERT <br />y* OR IN INSERT TEE <br />3" METER <br />96" <br />60'" <br />` DISTRIBUTION MAIN <br />6" <br />4" METER <br />108" <br />B0' M.J. ELBOW <br />48" <br />g^ <br />(RESTRAINED JOINTS <br />126" <br />DOMESTIC METER BOX <br />PLAN <br />NOTES: <br />1. 12" CLEARANCE REQUIRED UNDER BFP ASSEMBLIES <br />2, ASSE 1064 ENCLOSURE REQUIRED FOR BFV ASSEMBLIES <br />3. ONLY APPUCABLE TO MAINS � 6 INCHES <br />USC•FCCCHR & ASSE APPROVED REDUCED PRESSURE <br />DETECTOR ASSEMBLY (RP•D) <br />FIRE LINE <br />A A <br />L. -.. . ' 518" " METER TO BE PURCHASED FROM <br />PE X P,E <br />1 NIPPLE THE TOWN OF HILLSSOROUGH OR <br />` PROVIDED BY BFFPP TO TOWN SPEC <br />DOMESTIC SERVICE <br />USC- FCCCHR & ASSE APPROVED <br />SACKFLOW PREVENTER <br />PROPERTY LINE (TYPE AS REQUIRED) <br />SECTION A -A <br />SEE RP OF <br />BACKFLOW FOR FIRE LINE <br />SCALE: N.T.S. <br />0 <br />2 <br />Wd I dale <br />UNDISTuRS <br />SUBGRADE <br />DIMENSION <br />"A" <br />"B" <br />"C"' <br />"D" <br />WATER <br />METER TYPE <br />1X" METER <br />48" <br />36" <br />30" <br />4" <br />NEPTUNE T -10 <br />2" METER <br />54" <br />42" <br />30" <br />4 " <br />TRU /FLO <br />COMPOUND <br />3" METER <br />96" <br />60'" <br />48" <br />6" <br />4" METER <br />108" <br />66'" <br />48" <br />g^ <br />6" METER <br />126" <br />72" <br />54" <br />6" <br />8" METER <br />1 138" <br />1 78" <br />60" <br />6" <br />NEPTUNE <br />HP TURBINE <br />10" METER <br />163'" <br />84" <br />60" <br />6" <br />'MAXIMUM DEPTH IS 60 "; MIN. WALL THICKNESS 6" IN H -20 AREAS. <br />NOTES: <br />1. FLANGED BRONZE STRAINERS BY NEPTUNE SHALL BE INSTALLED IMMEDIATELY <br />BEFORE ALL 2" AND LARGER METERS WITH APPROPRIATELY SIZED SPACER <br />BETWEEN THE STRAINER AND METER <br />2. A SEPARATE ABOVE GROUND BACKFLOW PREVENTION DEVICE IS REQUIRED PER <br />TOH SPECIFICATIONS <br />3- PIPING > 1" THROUGH VAULTS SHALL BE FLANGED OR RESTRAINED DUCTILE IRON <br />OR COPPER (COMPRESSION JOINTSIFITTINGS) <br />4. METERS SHALL BE PURCHASED THROUGH THE TOH <br />5. 1-112"- 2- METER INSTALLATIONS SHALL USE A FORD 70 SERIES COPPERSETTER <br />WITH BALL VALVE INLET AND OUTLET (OR EQUAL) <br />6- HATCHES SHALL BE DOUBLE LEAF ALUMINUM DIAMOND PLATE H -20 RATED IN <br />TRAFFIC AREAS (300 PSF NON- TRAFFIC AREAS) DESIGN WITH HINGED LOCKING <br />SPRING LOADED DOORS WITH OPEN POSITION LOCK - HARDWARE TO BE STAINLESS <br />STEEL. HATCH SIZES [r0 BE CENTERED OVER METER) ARE AS FOLLOWS: <br />$.1. 1.5" METERS: 36"X 48" <br />6.2. 2" METERS: 42" x 54- <br />6.3. 3" AND 4" METERS: 60"X 6D' <br />6.4. 8', 8-AND 10" METERS: 48'X 72" UNLESS CUSTOM SIZE MANDATED BY TOH <br />7. TWO (2) 2" HOLES SHALL BE CUT NEAR HINGE AREA FOR RADIO READ <br />DEVICES <br />a- VAULTS SHOULD BE PROVIDED WITH STEPS OR A LADDER ACCESSIBLE FROM THE <br />HATCH WITH THE HATCH PLACEMENT ALLOWING VIEWING AND REMOVAL OF THE <br />METER.. <br />9�- <br />LC <br />'u �lal <br />PLAN <br />25" MIN. <br />23 �$' MAX. 5�" MINIMUM <br />7 Y2- V. Y" <br />} MIN. <br />25" MIN. <br />33 Y4" <br />SECTION A -A <br />STANDARD MANHOLE COVER & FRAME <br />28 114" <br />261/4 <br />26" <br />M1 4 <br />1 t,f 24" <br />�I 3" 3 " I VERTICAL <br />I� FACE OF COVER <br />34" <br />SECTION A -A <br />NOTES: WATERTIGHT MANHOLE COVER & FRAME <br />1. CASTINGS SHALL BE MADE -IN -USA CONFORMING TO ASTM A48, <br />CLASS 35B GRAY CAST IRON <br />2. MANHOLE FRAME & COVER TO BE H -20 LOAD RATED IN PAVED <br />AREAS <br />rev description <br />7 MANHOLE RING & COVER GRADE ADJUSTMENT <br />C4'/SCALE: N.T.S. <br />■ <br />date <br />2" hatch size & misc. dimensioning <br />KPK <br />MOM <br />D <br />PRECAST CONCRETE RING IN UNPAVED <br />KPK <br />1.4 <br />rev <br />description <br />app'd <br />date <br />9�- <br />LC <br />'u �lal <br />PLAN <br />25" MIN. <br />23 �$' MAX. 5�" MINIMUM <br />7 Y2- V. Y" <br />} MIN. <br />25" MIN. <br />33 Y4" <br />SECTION A -A <br />STANDARD MANHOLE COVER & FRAME <br />28 114" <br />261/4 <br />26" <br />M1 4 <br />1 t,f 24" <br />�I 3" 3 " I VERTICAL <br />I� FACE OF COVER <br />34" <br />SECTION A -A <br />NOTES: WATERTIGHT MANHOLE COVER & FRAME <br />1. CASTINGS SHALL BE MADE -IN -USA CONFORMING TO ASTM A48, <br />CLASS 35B GRAY CAST IRON <br />2. MANHOLE FRAME & COVER TO BE H -20 LOAD RATED IN PAVED <br />AREAS <br />rev description <br />7 MANHOLE RING & COVER GRADE ADJUSTMENT <br />C4'/SCALE: N.T.S. <br />■ <br />date <br />3 8" VALVE <br />C4.f SCALE: N.T.S. <br />EXIST. Gf <br />FINAL BACKFIL <br />INITIAL BACKFIL <br />6" #67 STON <br />WHEN ROCK <br />ENCOUNTEREL <br />EXIST. GRADE <br />UNDISTURBED SOIL <br />MINIMUM SIDE CLEARANCE <br />MAXIMUM SIDE CLEARANCE <br />NOTES: <br />1. TRENCHES REQUIRING SHORING AND BRACING, DIMENSIONS SHALL BE TAKEN <br />FROM THE INSIDE FACE OF THE SHORING AND BRACING. <br />2. NO ROCKS OR BOULDERS 4" OR LARGER TO BE USED IN INITIAL BACKFILL. <br />3• ALL BACKFILL MATERIAL SHALL BE SUITABLE NATIVE MATERIAL. <br />4. BACKFILL SHALL BE TAMPED IN 6" LAYERS IN TRAFFIC AREAS, 12" IN NON TRAFFIC AREAS. <br />TRENCH BOTTOM DIMENSIONS, <br />BACKFILLING REQUIREMENTS FOR <br />DUCTILE IRON, VITRIFIED CLAY <br />SCALE: N.T.S. <br />TX 2' CAST -IN -PLACE <br />IH CONCRETE PAD OR <br />4" PVC CLEANOUT V PRECAST CONCRETE RING <br />IN LINE WYE FITTING PROVIDED SH <br />AT TOP QUARTER OF THE MAIN. 13' -0 <br />SIDEWALK DE <br />CURB &GUTTER •. - I I - - - 2 x 4 END OF <br />I I I I II,I CONNECTION MARKER <br />" I MIN <br />MINIMUM GRADE OF 1.0 CAP <br />'PIPE <br />I L <br />COMPACTED SOIL 4" COMBINATION <br />�� 1116 OR 11B PIPE BEND WYE AND 118 <br />SECTION VIEW BEND <br />ENTIRE SERVICE OF SAME MATERIAL z <br />LU <br />(SCH.40 PVC) UNLESS IN PAVED <br />AREAS (WHERE THE WYE, BEND AND <br />RISER MUST BE DUCTILE IRON) aa <br />4" PVC CLEANOUT uJ 2' x 7 x 5 -THICK CAST -IN -PLACE <br />q� <br />I CONCRETE PAD OR PRECAST <br />CONCRETE RING <br />4" PIPE GAP <br />1116 OR 1!8 PIPE BE <br />WYE <br />PLAN VIEW <br />NOTES <br />1. CLEANOUT SHALL BE PLACED AT RIGHT -OF -WAY OR EDGE OF EASEMENT <br />2. DO NOT INSTALL CLEANOUT INSIDE A FENCE <br />3. CONNECTIONS TO 15" OUTFALLS AND GREATER MUST BE MADE INTO <br />MANHOLE <br />1 Sch 40 service & PVC plug I KPK 11/10117 <br />KPK{ <br />rev description app'd I date <br />4" SEWER TAP AND STUB -OUT <br />PAVED APPLICATION CLEAN OUT <br />C4.1/ SCALE: N.T.S. <br />�- M.J. WITH RESTRAINING <br />GLAND <br />O <br />RESILIENT WEDGE TAPPING VALVE <br />O FLANGE JOINT <br />SS TAPPING SLEEVE <br />SEE NOTE 2 & 3 <br />D <br />• r� a d' ' <br />W <br />NOTES: <br />1. TAPS ONTO EQUAL SIZED MAINS MUST BE CUTAND SLEEVED WITH A TEE AND MAIN <br />LINE VALVE INSTALLED <br />2. BOLTS AND NUTS FOR TAPPING SLEEVE SHALL BE STAINLESS STEEL <br />3. ALL TAPS 4" AND GREATER REQUIRE A STAINLESS STEEL TAPPING SLEEVE WITH <br />FULL CIRCUMFERENTIAL SEAL" MECHANICAL JOINT OUTLET AND STAINLESS STEEL <br />BOLTS <br />4. USE THRUST BLOCKING FORALL TAPS <br />5. DEPTH FROM GROUND SURFACE TO TOP OF BLOCKING SHALL BE GREATER THAN <br />HEIGHT OF BLOCKING <br />6. THE END OF THE TAPPING SLEEVE SHALL BE NO CLOSER THAN 4 FEETTO A JOINT <br />7. TAPS ONTO ASBESTOS - CEMENT (AC) OR PVC MAINS REQUIRE AN EXTENDED <br />LENGTH SLEEVE ON THE MAIN BEING TAPPED <br />S. A 314" TEST PLUG OR SLEEVE SHALL BE INSTALLED <br />rev <br />FLANGE JOINT <br />MAIN r <br />9 <br />•/. /, /, 1, <br />MINIMUM CONCRETE STRENGTH = 3000 PSI, <br />TAP <br />SIZE <br />DIMENSIONS IN FEET <br />NOTE: 2k Yx W CONCRETE PAD IOR <br />H <br />D <br />PRECAST CONCRETE RING IN UNPAVED <br />2.0 <br />1.4 <br />AREAS) REQUIRED ON ALL VALVES. <br />a" <br />STANDARD VALVE <br />• � � '� <br />1.4 <br />,BOX LID <br />.,d • ..p - • •'�-. <br />ra• <br />1.8 <br />4 A Y <br />.a. , . <br />5.0 <br />STANDARD VALVE <br />DOMESTIC CASTING LID <br />BO %TOP <br />(MARKED WATER OR SEWER AS <br />APPROPRIATE) <br />FINAL PAVEMENT <br />COURSE <br />_'. <br />- <br />CONCRETE ° <br />PAD VALVE BOX TOP <br />TAMPED VALVE BOX BOTTOM <br />BACKFILL <br />' '• •GATE ' <br />VALVE <br />MAIN <br />SCREW TYPE C <br />D o <br />TAM PED �-e ,'..'• °.:',• ;. , <br />BACKFILL <br />TYPICAL TWO -PIECE VALVE BOX <br />NOTES: <br />1. PREFERRED VALVE BOX IS MODEL 32562 -S, A SCREW -TYPE TWO PIECE <br />n <br />ADJUSTABLE HEIGHT BOX MANUFACTURED BY GENERAL FOUNDRIES. <br />OTHER SIMILAR MODELS ARE AVAILABLE WITH VARIABLE HEIGHT <br />SCREW TYPE VALVE. <br />RANGES AS NECESSARY. <br />BO %BOTTOM <br />(VARIABLE HEIGHT) <br />2. VALVE BOX NOT TO CONTACT WATER MAIN OR SEWER FORCE MAIN <br />3. CAST IRON TO CONFORM TO ASTM A48 CLASS 35B <br />4. TRAFFIC CASTINGS MUST BE 4,20 WHEEL LOADING RATED <br />5. FOR ANY VALVES OVER I Y DEEP, A VALVE STEM EXTENSION MUST BE <br />USED TO BRING TO A DEPTH OF NO MORE THAN 9, EXTENSION MUST <br />10 -I.4' <br />BE A MINIMUM OF V FOR MAINS IT AND LARGER. <br />6. TOTAL VALVE SOX WEIGHT: MINIMUM OF 65 LBS. <br />1 Added ref. to so", appllcaHonc KPK 1110117 <br />KPK <br />M descviptim app'd I date <br />Qf° <br />VALVE BOX ASSEMBLY <br />Hrlls " gh <br />AND GATE VALVE <br />P4 Box 429 <br />scale NTS drawing no. 1W5 -01 <br />101 East Orange Street <br />date JANUARY 2017 <br />Hillsborough, North Carolina 27278 <br />� ' <br />approved . e-' <br />919.732.1270 <br />Kwrwilh P. Keay, P.E., Tartu ErvrIex <br />3 8" VALVE <br />C4.f SCALE: N.T.S. <br />EXIST. Gf <br />FINAL BACKFIL <br />INITIAL BACKFIL <br />6" #67 STON <br />WHEN ROCK <br />ENCOUNTEREL <br />EXIST. GRADE <br />UNDISTURBED SOIL <br />MINIMUM SIDE CLEARANCE <br />MAXIMUM SIDE CLEARANCE <br />NOTES: <br />1. TRENCHES REQUIRING SHORING AND BRACING, DIMENSIONS SHALL BE TAKEN <br />FROM THE INSIDE FACE OF THE SHORING AND BRACING. <br />2. NO ROCKS OR BOULDERS 4" OR LARGER TO BE USED IN INITIAL BACKFILL. <br />3• ALL BACKFILL MATERIAL SHALL BE SUITABLE NATIVE MATERIAL. <br />4. BACKFILL SHALL BE TAMPED IN 6" LAYERS IN TRAFFIC AREAS, 12" IN NON TRAFFIC AREAS. <br />TRENCH BOTTOM DIMENSIONS, <br />BACKFILLING REQUIREMENTS FOR <br />DUCTILE IRON, VITRIFIED CLAY <br />SCALE: N.T.S. <br />TX 2' CAST -IN -PLACE <br />IH CONCRETE PAD OR <br />4" PVC CLEANOUT V PRECAST CONCRETE RING <br />IN LINE WYE FITTING PROVIDED SH <br />AT TOP QUARTER OF THE MAIN. 13' -0 <br />SIDEWALK DE <br />CURB &GUTTER •. - I I - - - 2 x 4 END OF <br />I I I I II,I CONNECTION MARKER <br />" I MIN <br />MINIMUM GRADE OF 1.0 CAP <br />'PIPE <br />I L <br />COMPACTED SOIL 4" COMBINATION <br />�� 1116 OR 11B PIPE BEND WYE AND 118 <br />SECTION VIEW BEND <br />ENTIRE SERVICE OF SAME MATERIAL z <br />LU <br />(SCH.40 PVC) UNLESS IN PAVED <br />AREAS (WHERE THE WYE, BEND AND <br />RISER MUST BE DUCTILE IRON) aa <br />4" PVC CLEANOUT uJ 2' x 7 x 5 -THICK CAST -IN -PLACE <br />q� <br />I CONCRETE PAD OR PRECAST <br />CONCRETE RING <br />4" PIPE GAP <br />1116 OR 1!8 PIPE BE <br />WYE <br />PLAN VIEW <br />NOTES <br />1. CLEANOUT SHALL BE PLACED AT RIGHT -OF -WAY OR EDGE OF EASEMENT <br />2. DO NOT INSTALL CLEANOUT INSIDE A FENCE <br />3. CONNECTIONS TO 15" OUTFALLS AND GREATER MUST BE MADE INTO <br />MANHOLE <br />1 Sch 40 service & PVC plug I KPK 11/10117 <br />KPK{ <br />rev description app'd I date <br />4" SEWER TAP AND STUB -OUT <br />PAVED APPLICATION CLEAN OUT <br />C4.1/ SCALE: N.T.S. <br />�- M.J. WITH RESTRAINING <br />GLAND <br />O <br />RESILIENT WEDGE TAPPING VALVE <br />O FLANGE JOINT <br />SS TAPPING SLEEVE <br />SEE NOTE 2 & 3 <br />D <br />• r� a d' ' <br />W <br />NOTES: <br />1. TAPS ONTO EQUAL SIZED MAINS MUST BE CUTAND SLEEVED WITH A TEE AND MAIN <br />LINE VALVE INSTALLED <br />2. BOLTS AND NUTS FOR TAPPING SLEEVE SHALL BE STAINLESS STEEL <br />3. ALL TAPS 4" AND GREATER REQUIRE A STAINLESS STEEL TAPPING SLEEVE WITH <br />FULL CIRCUMFERENTIAL SEAL" MECHANICAL JOINT OUTLET AND STAINLESS STEEL <br />BOLTS <br />4. USE THRUST BLOCKING FORALL TAPS <br />5. DEPTH FROM GROUND SURFACE TO TOP OF BLOCKING SHALL BE GREATER THAN <br />HEIGHT OF BLOCKING <br />6. THE END OF THE TAPPING SLEEVE SHALL BE NO CLOSER THAN 4 FEETTO A JOINT <br />7. TAPS ONTO ASBESTOS - CEMENT (AC) OR PVC MAINS REQUIRE AN EXTENDED <br />LENGTH SLEEVE ON THE MAIN BEING TAPPED <br />S. A 314" TEST PLUG OR SLEEVE SHALL BE INSTALLED <br />rev <br />FLANGE JOINT <br />MAIN r <br />9 <br />•/. /, /, 1, <br />MINIMUM CONCRETE STRENGTH = 3000 PSI, <br />TAP <br />SIZE <br />DIMENSIONS IN FEET <br />W <br />H <br />D <br />4" & 6" <br />2.0 <br />1.4 <br />1.0 <br />a" <br />3 -5 <br />2.0 <br />1.4 <br />10" <br />4.0 <br />25 <br />1.8 <br />12" <br />5.0 <br />3.0 <br />2.5 <br />date <br />N: /0000 /CML /SPECIFIC DETS- HILLSBOROUGH/ C4■ SCALE: N.T.S. 0000 /HILLSBOROUGH/TAPPING SLEEVE.DWG <br />HILLSBOROUGH DETS -NEW <br />222 cloister court <br />chapel hill, nc 27514 <br />919.401.8586 <br />www.cra- ae.com <br />Lv <br />la� <br />z <br />� O <br />Z o <br />0 X w <br />V Uu V) J � u <br />W a z <br />0 = <br />Z~= o <br />140 J ° <br />W J <br />OH z <br />no. revisions <br />1 <br />ADDENDUM #1 <br />07/20/17 <br />11/01/17 <br />drawn checked <br />ETS MLH <br />UTILITIES <br />DETAILS <br />sheet <br />C4ml <br />date project no. <br />12/15/2017 1613 <br />