Orange County NC Website
24 <br />met with Robert Kirkley at their home located at 4020 Jones Ferry Road on Wednesday <br />2114118. Robert showed Warren and Wesley the location of the septic tank drainfield and <br />the well location. We noticed that the existing septic field showed no signs of failure. It <br />appears to be working correctly at this time. The Kirkleys are concerned about their <br />options when and if the septic system fails in the future. The letter from Jeff Vaughan <br />states that the only repair septic system suitable for this lot is a surface wastewater <br />discharge system. These types of systems are state approved systems. Mr. Mitchell has <br />designed several of these systems and Mr. Lloyd has installed many of these systems. <br />The system will treat the wastewater first with the septic tank and next with a sand filter or <br />proprietary system like the Advantex by Orenco Systems. This system would be installed <br />next to their existing septic system and the treated wastewater would discharge into the <br />small creek behind their house. It appears that their existing well could remain where it is <br />in the northeast corner of their property. There are other possible locations for another <br />well on their property but the system proposed by Mr. Vaughn doesn't require the well to <br />be relocated or abandoned. Their existing well is approximately 75 feet from our common <br />property line where we show the proposed septic systems for Lots 1, 2, 3, 4 and 6. We <br />prepared a sketch of the system that Mr. Vaughan proposed for the Kirkley's septic <br />system repair. <br />Staff Note: After the 216118 Planning Board meeting and during discussion regarding the <br />off -site septic areas with the developer, it was discovered that the original soils map <br />included in the First Plat submittal and prepared by Central Carolina Soil Consulting, <br />PLLC did not identify the well located on the Kirkley's property that is 75 feet from the <br />common boundary line with Morgan Ridge and the location of the 5 proposed off -site <br />septic areas. Chatham County requires a 100 foot separation between a well and a septic <br />system unless there is a `fixed lot condition' which may allow the distance to be reduced <br />to 50 feet. Per Environmental Health, this is not considered a `fixed lot condition'. <br />Thomas Boyce requested a revised soils map showing the Kirkley's existing well and <br />showing a 10.0 foot separation from the proposed 5 off -site septic areas. Jason Hall, Soil <br />Scientist, provided a revised map, see attachment # 16. Mr. Boyce reviewed and stated <br />that "the septic layout now meets the 100' setback to the neighboring well ". See <br />attachment # 17. <br />*Development is located in an area designated as a Conservation Area in the newly <br />adopted Comprehensive Plan. Did the developer consider doing a Conservation <br />Subdivision which is encouraged in a Conservation Area? A Board member noted that <br />there are limitations on a Conservation Subdivision when wells and septic systems are <br />required. We like the Conservation Subdivision concept but we don't think that this <br />property is ideal for that type of design. The natural features, namely the stream buffers <br />and wetland are linear in shape. The usable area on the property is also linear like the <br />buffers. This makes it difficult to cluster the homes together in a compact manner. The <br />roadway would be the same length in a conservation layout on this property because over <br />half of the useable area is across Meadow Branch Creek. <br />*Concern that Meadow Branch drains to Terrell's Creek which drains to the Haw River <br />and there is a rare species in the river and this is a sensitive watershed. Acknowledge <br />Page 9 of 6 <br />