Browse
Search
2018-093-E AMS - Century Slate Company Replace roof at SDC
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-093-E AMS - Century Slate Company Replace roof at SDC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/23/2019 4:25:01 PM
Creation date
3/19/2018 5:26:12 PM
Metadata
Fields
Template:
Contract
Date
3/14/2018
Contract Starting Date
3/14/2018
Contract Ending Date
5/30/2018
Contract Document Type
Agreement - Construction
Amount
$43,255.00
Document Relationships
R 2018-093 AMS - Century Slate Company Replace roof at SDC
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
168
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: B49FB256 -4ADF- 4759- AF63- 134AD44FC239 <br />5thWall Building Diagnostics Consultants Slate Roof Replacement <br />Orange County Skills Development Center <br />Chapel Hill, NC <br />August 2017 <br />G. Relocate and protect satellites, antennas, and security cameras to be reused. Temporarily <br />relocated items must remain operational unless otherwise coordinated with the Owner's <br />representative. Coordinate all movement with the Owner or Owner's Representative. <br />3.02 Deck <br />A. Inspect deck for damage detrimental to the new roof system. Repair as needed prior to <br />installation of new roof system. Verify areas deemed in need of repair with Designer <br />prior to proceeding with work. <br />B. Remove and dispose of damaged or deteriorated deck. Exercise caution so as not to damage <br />supporting structural units. <br />C. Should structural units be damaged, notify Owner and Designer for resolution prior to <br />installing new deck. <br />D. All repaired or replaced deck shall be verified by the Owner's Representative. <br />E. Repair or replace deck in accordance with Section 061000, Rough Carpentry. <br />3.03 Deck Opening Repair <br />A. Remove and replace decking for penetrations identified to be removed. Openings 24 <br />inches in diameter or square or less shall be covered with 18 gauge galvanized sheet <br />metal plate. Plate shall extend a minimum of 8 inches beyond the perimeters of the <br />opening and shall be secured with fasteners, minimum 2 per side. <br />B. Openings larger than noted in 3.03.A shall be structurally framed in with supporting steel <br />and closed in with deck of same thickness to match existing. New deck shall be secured <br />as described in Section 053100, Steel Deck. <br />END OF SECTION <br />17 -198 Selective Demolition <br />024119 -3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.