Orange County NC Website
DocuSign Envelope ID: 313DA256 -1EDE- 4396- A716- 4C53B809027E <br />JERRY M. PASSMORE CENTER ADDITION AND RENOVATION <br />HILLSBOROUGH, NORTH CAROLINA <br />B. Roof -Paver Walkways: Install walkway roof pavers according to manufacturer's written <br />instructions in locations indicated, to form walk surface. Leave 1/2 inch (12 mm) of space <br />between adjacent roof pavers. <br />3.8 FIELD QUALITY CONTROL <br />A. Testing Agency: Owner will engage a qualified testing agency to perform tests and inspections. <br />B. Final Roof Inspection: Arrange for roofing system manufacturer's technical personnel to <br />inspect roofing installation on completion. <br />C. Repair or remove and replace components of membrane roofing system where inspections <br />indicate that they do not comply with specified requirements. <br />D. Additional inspections, at Contractor's expense, will be performed to determine compliance of <br />replaced or additional work with specified requirements. <br />3.9 PROTECTING AND CLEANING <br />A. Protect membrane roofing system from damage and wear during remainder of construction <br />period. When remaining construction will not affect or endanger roofing, inspect roofing for <br />deterioration and damage, describing its nature and extent in a written report, with copies to <br />Architect and Owner. <br />B. Correct deficiencies in or remove membrane roofing system that does not comply with <br />requirements; repair substrates; and repair or reinstall membrane roofing system to a condition <br />free of damage and deterioration at time of Acceptance and according to warranty requirements. <br />END OF SECTION 075423 <br />THERMOPLASTIC POLYOLEFIN (TPO) ROOFING (Alternate G -2) (Addendum #1) 075423-11 <br />