2018-053-E AMS - HM Kern Passmore Addition
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-053-E AMS - HM Kern Passmore Addition
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/23/2019 4:16:44 PM
Creation date
2/26/2018 10:49:57 AM
Metadata
Fields
Template:
Contract
Date
1/23/2018
Contract Starting Date
1/23/2018
Contract Document Type
Agreement - Construction
Agenda Item
8-I
Amount
$494,820.00
Document Relationships
2019-180-E AMS - HM Kern Passmore Center landscaping contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-191-E AMS - HM Kern Corporation Passmore Center contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
R 2018-053 AMS - HM Kern Passmore Expansion
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
630
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 313DA256 -1EDE- 4396- A716- 4C53B809027E <br />JERRY M. PASSMORE CENTER ADDITION AND RENOVATION <br />HILLSBOROUGH, NORTH CAROLINA <br />C. Do not install panels that are wet, those that are moisture damaged, and those that are mold <br />damaged. <br />1. Indications that panels are wet or moisture damaged include, but are not limited to, <br />discoloration, sagging, or irregular shape. <br />2. Indications that panels are mold damaged include, but are not limited to, fuzzy or <br />splotchy surface contamination and discoloration. <br />PART 2- PRODUCTS <br />2.1 PERFORMANCE REQUIREMENTS <br />A. Fire - Resistance -Rated Assemblies: For fire- resistance -rated assemblies, provide materials and <br />construction identical to those tested in assembly indicated according to ASTM E 119 by an <br />independent testing agency. <br />B. STC -Rated Assemblies: For STC -rated assemblies, provide materials and construction identical <br />to those tested in assembly indicated according to ASTM E 90 and classified according to <br />ASTM E 413 by an independent testing agency. <br />2.2 GYPSUM BOARD, GENERAL <br />A. Size: Provide maximum lengths and widths available that will minimize joints in each area and <br />that correspond with support system indicated. <br />A. Manufacturers: Subject to compliance with requirements, provide products by one of the <br />following: <br />1. American Gypsum. <br />2. CertainTeed Corp. <br />3. Georgia- Pacific Gypsum LLC. <br />4. Lafarge North America Inc. <br />5. National Gypsum Company. <br />6. PABCO Gypsum. <br />7. Temple - Inland. <br />8. USG Corporation. <br />B. Gypsum Board, Type X: ASTM C 1396/C 1396M. <br />1. Thickness: 5/8 inch (15.9 mm). <br />2. Long Edges: Tapered and featured (rounded or beveled) for prefilling. <br />C. Gypsum Ceiling Board: ASTM C 1396/C 1396M. <br />1. Thickness: 1/2 inch (12.7 mm). <br />GYPSUM BOARD 092900-2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.