Browse
Search
2018-053-E AMS - HM Kern Passmore Addition
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-053-E AMS - HM Kern Passmore Addition
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/23/2019 4:16:44 PM
Creation date
2/26/2018 10:49:57 AM
Metadata
Fields
Template:
Contract
Date
1/23/2018
Contract Starting Date
1/23/2018
Contract Document Type
Agreement - Construction
Agenda Item
8-I
Amount
$494,820.00
Document Relationships
2019-180-E AMS - HM Kern Passmore Center landscaping contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-191-E AMS - HM Kern Corporation Passmore Center contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
R 2018-053 AMS - HM Kern Passmore Expansion
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
630
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 313DA256 -1EDE- 4396- A716- 4C53B809027E <br />JERRY M. PASSMORE CENTER ADDITION AND RENOVATION <br />HILLSBOROUGH, NORTH CAROLINA <br />3. Interspace Content: Air. <br />4. Outdoor Lite: Class 1 (clear) float glass. <br />a. Kind FT (fully tempered). <br />5. Indoor Lite: Class 1 (clear) float glass. <br />a. Kind FT (fully tempered). <br />6. <br />Low -E Coating: Sputtered on second surface. <br />7. <br />Visible Light Transmittance: <br />36 percent minimum. <br />8. <br />Winter Nighttime U- Factor: <br />0.31 maximum. <br />9. <br />Summer Daytime U- Factor: <br />0.29 maximum. <br />10. <br />Solar Heat Gain Coefficient: <br />0.28 maximum. <br />11. <br />Outdoor Visible Reflectance: <br />0.15 percent maximum. <br />PART 3 - EXECUTION <br />3.1 EXAMINATION <br />A. Examine framing glazing, with Installer present, for compliance with the following: <br />1. Manufacturing and installation tolerances, including those for size, squareness, and <br />offsets at corners. <br />2. Presence and functioning of weep system. <br />3. Minimum required face or edge clearances. <br />4. Effective sealing between joints of glass - framing members. <br />B. Proceed with installation only after unsatisfactory conditions have been corrected. <br />K�► ' ; ' .1W. 11 1 632 <br />A. Clean glazing channels and other framing members receiving glass immediately before glazing. <br />Remove coatings not firmly bonded to substrates. <br />3.3 GLAZING, GENERAL <br />A. Comply with combined written instructions of manufacturers of glass, sealants, gaskets, and <br />other glazing materials, unless more stringent requirements are indicated, including those in <br />referenced glazing publications. <br />B. Glazing channel dimensions, as indicated on Drawings, provide necessary bite on glass, <br />minimum edge and face clearances, and adequate sealant thicknesses, with reasonable <br />tolerances. Adjust as required by Project conditions during installation. <br />C. Protect glass edges from damage during handling and installation. Remove damaged glass from <br />Project site and legally dispose of off Project site. Damaged glass is glass with edge damage or <br />GLAZING 088000- 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.