Orange County NC Website
DocuSign Envelope ID: 313DA256 -1EDE- 4396- A716- 4C53B809027E <br />JERRY M. PASSMORE CENTER ADDITION AND RENOVATION <br />HILLSBOROUGH, NORTH CAROLINA <br />a. Submittal Sequence: Submit door hardware schedule concurrent with submissions <br />of Product Data, Samples, and Shop Drawings. Coordinate submission of door <br />hardware schedule with scheduling requirements of other work to facilitate the <br />fabrication of other work that is critical in Project construction schedule. <br />b. Format: Use same scheduling sequence and format and use same door numbers as <br />in the Contract Documents. <br />C. Content: Include the following information: <br />1) Identification number, location, hand, fire rating, size, and material of each <br />door and frame. <br />2) Locations of each door hardware set, cross - referenced to Drawings on floor <br />plans and to door and frame schedule. <br />3) Complete designations, including name and manufacturer, type, style, <br />function, size, quantity, function, and finish of each door hardware product. <br />4) Description of electrified door hardware sequences of operation and <br />interfaces with other building control systems. <br />5) Fastenings and other pertinent information. <br />6) Explanation of abbreviations, symbols, and codes contained in schedule. <br />7) Mounting locations for door hardware. <br />8) List of related door devices specified in other Sections for each door and <br />frame. <br />2. Keying Schedule: Prepared by or under the supervision of Installer, detailing Owner's <br />final keying instructions for locks. Include schematic keying diagram and index each key <br />set to unique door designations that are coordinated with the Contract Documents. <br />1.4 INFORMATIONAL SUBMITTALS <br />A. Qualification Data: For Installer and Architectural Hardware Consultant. <br />B. Product Certificates: For electrified door hardware, from the manufacturer. <br />Certify that door hardware approved for use on types and sizes of labeled fire -rated doors <br />complies with listed fire -rated door assemblies. <br />C. Product Test Reports: For compliance with accessibility requirements, based on evaluation of <br />comprehensive tests performed by manufacturer and witnessed by a qualified testing agency, <br />for door hardware on doors located in accessible routes. <br />D. Warranty: Special warranty specified in this Section. <br />1.5 CLOSEOUT SUBMITTALS <br />A. Maintenance Data: For each type of door hardware to include in maintenance manuals. Include <br />final hardware schedule. <br />DOOR HARDWARE 087100-2 <br />