2018-053-E AMS - HM Kern Passmore Addition
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-053-E AMS - HM Kern Passmore Addition
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/23/2019 4:16:44 PM
Creation date
2/26/2018 10:49:57 AM
Metadata
Fields
Template:
Contract
Date
1/23/2018
Contract Starting Date
1/23/2018
Contract Document Type
Agreement - Construction
Agenda Item
8-I
Amount
$494,820.00
Document Relationships
2019-180-E AMS - HM Kern Passmore Center landscaping contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
2019-191-E AMS - HM Kern Corporation Passmore Center contract amendment
(Message)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2019
R 2018-053 AMS - HM Kern Passmore Expansion
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
630
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 313DA256 -1EDE- 4396- A716- 4C53B809027E <br />JERRY M. PASSMORE CENTER ADDITION AND RENOVATION <br />HILLSBOROUGH, NORTH CAROLINA <br />B. Steel Reinforcement: Reinforcement with corrosion- resistant primer complying with SSPC -PS <br />Guide No. 12.00 applied immediately after surface preparation and pretreatment. Use surface <br />preparation methods according to recommendations in SSPC -SP COM and prepare surfaces <br />according to applicable SSPC standard. <br />C. Glazing: As specified in Section 088000 Glazing <br />D. Sealants and Joint Fillers: As specified in Section 079200 "Joint Sealants." <br />E. Nonmetallic, Shrinkage- Resistant Grout: Premixed, nonmetallic, noncorrosive, nonstaining <br />grout; complying with ASTM C 1107 /C 1107M; of consistency suitable for application. <br />F. Bituminous Coating: Cold- applied asphalt emulsion complying with ASTM D 1187. <br />G. Fasteners and Accessories: Corrosion- resistant, nonstaining, nonbleeding fasteners and <br />accessories compatible with adjacent materials. <br />2.6 DOOR OPERATORS AND CONTROLS <br />A. General: Provide operators and controls, which include activation and safety devices, according <br />to BHMA standards, for condition of exposure, and for long -term, maintenance -free operation <br />under normal traffic load for type of occupancy indicated. <br />B. Door Operators: Provide door operators of size recommended by manufacturer for door size, <br />weight, and movement. <br />1. Door Operator Performance: Door operators shall open and close doors and maintain <br />them in fully closed position when subjected to Project's design wind loads. <br />2. Electromechanical Operators: Concealed, self - contained, overhead unit powered by <br />fractional- horsepower, permanent - magnet do motor; with closing speed controlled <br />mechanically by gear train and dynamically by braking action of electric motor; with <br />solid -state microprocessor controller; UL 325; and with manual operation with power off. <br />C. Motion Sensors: Self- contained, K- band - frequency, microwave - scanner units; fully enclosed by <br />its plastic housing; adjustable to provide detection -field sizes and functions required by <br />BHMA A156.10. <br />D. Presence Sensors: Self- contained, active - infrared scanner units; adjustable to provide detection - <br />field sizes and functions required by BHMA At 56.10. Sensors shall remain active at all times. <br />E. Photoelectric Beams: Pulsed infrared, sender - receiver assembly for recessed mounting. Beams <br />shall not be active when doors are fully closed. <br />F. Electrical Interlocks: Unless units are equipped with self - protecting devices or circuits, provide <br />electrical interlocks to prevent activation of operator when door is locked, latched, or bolted. <br />SLIDING AUTOMATIC ENTRANCES 084229-6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.