Browse
Search
2018-029-E AMS - 5th Wall building diagnostics site assessment
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2018
>
2018-029-E AMS - 5th Wall building diagnostics site assessment
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 3:39:48 PM
Creation date
2/5/2018 3:23:32 PM
Metadata
Fields
Template:
Contract
Date
1/29/2018
Contract Starting Date
1/29/2018
Contract Document Type
Agreement - Consulting
Amount
$12,200.00
Document Relationships
R 2018-029 AMS - 5th Wall Building Diagnostics 3800 Site Assessment
(Attachment)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: B4675608- 0914 -497F- 9792- 29C934DA6B3A <br />Jeff Thompson <br />Limited Property Condition Assessment <br />3800 Hwy 70 <br />Mebane, NC <br />5thwall Proposal No. 18 -01 -01 <br />January 24, 2018 <br />Page 2 <br />Please note that observations will be conducted in a furnished and occupied building, wherein the <br />majority of the structural elements may be covered or encased by building finishes and not visible in a <br />"walk- through" type observation. Also note that it is possible that conditions may exist underground <br />or within concealed framing spaces that may affect the performance of the building that will not be <br />discovered by the assessment. We will endeavor to ascertain visually apparent structural distress, but <br />cannot be expected to identify deficiencies which are not visible due to building finishes or other <br />obscuring conditions. Invasive investigation to identify concealed issues is not included in the scope <br />of services. <br />• Roofing/Building Envelope <br />Roofing Systems <br />Roofing systems will be observed via walk -over. The assessment will note field observations of <br />general appearance, surface conditions, signs of damage, roof membrane conditions, and include <br />estimated life expectancy. Itemized general cost estimates to correct deficiencies and roof <br />replacement costs will be provided as appropriate. Actual testing of the roof membrane or substrate <br />to identify problems that are subsurface in nature, i.e., wet insulation, deteriorated deck, etc., may not <br />be discovered is not included in the assessment. If substrate problems are suspected, additional <br />services may be recommended. <br />Building Envelope (Walls, Fenestration, Doors, Penetrations) <br />Observations will be made of exterior wall finishes to evaluate cladding, glazing, metal, and sealants <br />for general condition and signs of distress or deterioration. Observations will be performed from <br />locations that are accessible such as from the ground and roof surfaces where applicable. Use of <br />swing stages, lifts, or other investigation equipment is not included in this assessment. <br />• Mechanical/Electrical/Plumbing <br />We will observe mechanical, electrical, and plumbing systems where readily visible and accessible, <br />and provide general information about the types of systems and materials in use as well as an opinion <br />regarding anticipated remaining useful service life of in -place equipment. <br />Mechanical (HVAQ <br />Observations will be made regarding the general physical condition and operation of components <br />exposed to view. Representations regarding adequacy of load, equipment, etc. are beyond the scope <br />of this survey. Mechanical systems will be activated to assure that components operate in appropriate <br />mode e.g. heating and cooling as appropriate. <br />Electrical (service, lighting, outlets) <br />Observations will be made regarding the general physical condition and operation of components <br />exposed to view. Representations regarding adequacy of circuits, load, etc. are beyond the scope of <br />this assessment. Selected switches and outlets will be activated to assure proper operation and <br />delivery of electricity. <br />9601 Baileywick Rd • Raleigh, NC 27615 www.5thwallbdc.com <br />919/616 -4715 <br />