Browse
Search
Agenda - 02-06-2018 5-a - Class A Special Use Permit – Solar Array off US Highway 70 in Cheeks Township
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2010's
>
2018
>
Agenda - 02-06-2018 Regular Meeting
>
Agenda - 02-06-2018 5-a - Class A Special Use Permit – Solar Array off US Highway 70 in Cheeks Township
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/2/2018 10:59:59 AM
Creation date
2/2/2018 11:01:01 AM
Metadata
Fields
Template:
BOCC
Document Relationships
Agenda - 02-06-2018 Regular Board Meeting
(Message)
Path:
\Board of County Commissioners\BOCC Agendas\2010's\2018\Agenda - 02-06-2018 Regular Meeting
Minutes 02-06-2018
(Message)
Path:
\Board of County Commissioners\Minutes - Approved\2010's\2018
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
228
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
145 <br />REQUIREMENT <br />UDO <br />SUPPORTING EVIDENCE <br />Staff <br />Planning <br />Board <br />Recomm <br />endation <br />STANDARDS for Solar Arra — Public Utilit <br />Site Plan <br />5.9.6 (C) (1) <br />Application, Applicant Testimony, <br />Yes <br />Yes <br />A site plan prepared in accordance <br />(a) through <br />Staff Testimony, and Site Plan. <br />with Section 2.5 of and 5.9.6 (C) (1) <br />(d) <br />Site plan provides elevations for <br />inclusive of UDO <br />proposed arrays, fencing and <br />landscaping. <br />The application, EA and Phase I <br />Environmental contain required <br />soils information and reports <br />(Attachment 1) <br />Standards of Evaluation <br />5.9.6 (C) (2) <br />Application, Applicant Testimony, <br />Yes <br />Yes <br />On -site utility and transmission <br />(a) <br />Staff Testimony, and Site Plan <br />lines placed underground when <br />(Attachments 1 and 2). <br />feasible <br />5.9.6 (C) (2) <br />Application, Applicant Testimony, <br />Yes <br />Yes <br />Height of array shall not exceed 40 <br />(b) <br />Staff Testimony, and Site Plan <br />ft. <br />(Attachments 1 and 2). <br />5.9.6 (C) (2) <br />Application, Applicant Testimony, <br />Yes <br />Yes <br />Individual arrays shall be designed <br />(c) <br />Staff Testimony, and Site Plan <br />and located to prevent reflective <br />(Attachments 1 and 2). <br />glare toward inhabited buildings on <br />adjacent property and rights-of- <br />way. <br />Warning signs concerning voltage. <br />5.9.6 (C) (2) <br />Application, Applicant Testimony, <br />Yes <br />Yes <br />(d) <br />Staff Testimony, and Site Plan <br />Attachments 1 and 2). <br />Mechanical equipment and arrays <br />5.9.6 (C) (2) <br />Application, Applicant Testimony, <br />Yes <br />Yes <br />shall be enclosed by a minimum 8 <br />(e) <br />Staff Testimony, and Site Plan <br />ft. high fence and screening per <br />(Attachments 1 and 2). <br />Section 6.8 of UDO. <br />Proof of liability insurance — <br />5.9.6 (C) (2) <br />Application and Applicant <br />Yes <br />Yes <br />minimum of $500,000.00 per <br />(f) <br />Testimony (Attachment 1). <br />occurrence. <br />Type D land use buffer around <br />5.9.6 (C) (2) <br />Application, Applicant Testimony, <br />Yes <br />Yes <br />perimeter of project <br />(g) <br />Staff Testimony, and Site Plan <br />(Attachments 1 and 2). <br />
The URL can be used to link to this page
Your browser does not support the video tag.