Orange County NC Website
<br />Name: Mr, And Mrs, Grasty <br />Address: 119 Hayes Street <br />City: Hillsborough <br />Phone #: 732-3608 <br />Date: <br />Page 4 of 15 <br />8, Remove existing crawlspace access door, wall panel and framing at <br />crawlspace entrance. Excavate immediately under this location to a depth <br />of 8" below interior grade and prepare soil for installation of new concrete <br />footing and concrete block walk Footing to be 8" deep and 15" wide. <br />Supply and install new concrete footing and concrete block wall. New <br />block wall to extend to bottom of existing porch floor joist and allow for <br />wood access panel of size approximately same as existing, with minimum <br />one continuous course of block below access opening, Includes fill voids <br />in concrete block with concrete. Includes mortar between top of block <br />wall and bottom of floorjoist. New access door to be approximately same <br />size as existing door, framed and cross-braced with treated 2 x 4 lumber, <br />%z" plywood face, galvanized metal lunges, locking hasp and lock, <br />complete, Includes prime and exterior latex finish paint to match existing <br />as close as practical. Finish paint shall provide sufficient coverage to <br />prevent previous colors from showing through. Overall total dimensions <br />ofwall and doorpanel are approximately 6'W x 5'6"H. <br />9. Remove existing concrete pavers from approximately 13 l.f, of the exterior <br />rear wall of the house. Stack concrete pavers in area designated by owner. <br />Remove soil from top of foundation, Remove soil to approximately 24" <br />away from house, sloping from 2" below top of foundation to <br />approximately 3" below existing soil grade at 24" away from house. Any <br />trenching spoils to be distributed on site as directed by owner. <br />Trim approximately 13 Lf of exposed edge of existing siding substrate to <br />give clean edge at bottom of lowest siding board on house. Supply and <br />install galvanized metal flashing extending from under lower edge of <br />exterior siding, flush on exposed girder, down to approximately 1" below <br />top of foundation. Flashing to be sealed to top of foundation. <br />Supply and install new concrete slab approximately 13'long x 2'wide x <br />approximately 3"deep with welded wire mesh reinforcing. Top of slab to <br />be 3" above top of foundation wall, slope uniformly away from house to <br />top of existing soil grade 2' away from house, and be not les than 3" thick <br />at any point. <br />Supply and install new lx band board approximately 13 Lf. of treated <br />material extending from bottom of existing siding board to within 1 %z" of <br />top ofnew concrete slab. <br />