Browse
Search
Agenda - 01-23-2018 5-a - Zoning Atlas Amendment - Conditional Zoning – Master Plan Development Conditional Zoning District (MPD-CZ) Settlers Point
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2010's
>
2018
>
Agenda - 01-23-2018
>
Agenda - 01-23-2018 5-a - Zoning Atlas Amendment - Conditional Zoning – Master Plan Development Conditional Zoning District (MPD-CZ) Settlers Point
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/22/2018 10:29:32 AM
Creation date
1/22/2018 8:39:32 AM
Metadata
Fields
Template:
BOCC
Date
1/23/2018
Meeting Type
Regular Meeting
Document Type
Agenda
Agenda Item
5-a
Document Relationships
Agenda - 01-23-2018 - Regular Meeting Agenda
(Message)
Path:
\Board of County Commissioners\BOCC Agendas\2010's\2018\Agenda - 01-23-2018
Minutes 01-23-2018
(Message)
Path:
\Board of County Commissioners\Minutes - Approved\2010's\2018
Statement of Approval and Consistency Statement - Settler's Point 012318
(Message)
Path:
\Board of County Commissioners\Various Documents\2010 - 2019\2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
172 <br />j. LIGHTING: All proposed lighting shall comply with the standards <br />detailed in Section 6.11 Outdoor Lighting of the UDO. Outdoor <br />liqhtinq shall be extinguished after normal business hours to <br />eliminate the potential for glare and light pollution consistent with <br />appropriate industry guideline standards including, but not limited <br />to: IES /ANSI, OSHA, etc. in order to maintain safe lighting <br />conditions for employees, business owners and the public. 16 <br />k. SIGNAGE: In addition to the standards detailed in Section 6.12 <br />Signage of the UDO, development within the Project shall abide by <br />the following: <br />i. Unless otherwise specified herein, signs shall be composed <br />of individual internally lit letters. <br />ii. Approved copyright logos shall be allowed on signage in a <br />box type fashion. <br />iii. The signage shall be permitted for the Project: <br />1. One (1) architectural landmark freestanding sign <br />serving as a visual identifier for the Project subject to <br />the following standards: <br />a. Maximum height of 50 ft. <br />b. Allowable sign area of 400 sq.ft. per sign face. <br />c. Shall comply with principal setbacks for the <br />District in which it is located. <br />2. Eight (8) entry portal freestanding signs providing the <br />name of the development and identifying tenants <br />subject to the following standards: <br />a. Maximum Height of 8 ft. <br />b. Allowable sign area of 300 sq.ft. <br />c. 10 ft. setback from all rights -of -way and /or <br />property lines. <br />d. Sign shall be composed of either <br />raised /blocked lettering or shall be a wall sign. <br />+ho I Inc) 17 <br />60% of the sign area shall contain the name of <br />the Project. <br />3. Signage for theater shall abide by the following <br />standards: <br />16 A condition recommended for addition by the Planning Board to address concerns over light pollution. The <br />wording of the condition was suggested by the applicant. At its January 10, 2018 regular meeting, the Planning <br />Board voted unanimously to recommend approval of the applicant's proposed language. <br />17 This language was improperly added by staff. The narrative for the Project indicates all signs shall be internally <br />illuminated. <br />