Browse
Search
Agenda - 06-13-2006-9c
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2000's
>
2006
>
Agenda - 06-13-2006
>
Agenda - 06-13-2006-9c
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2008 3:41:59 PM
Creation date
8/29/2008 9:34:33 AM
Metadata
Fields
Template:
BOCC
Date
6/13/2006
Document Type
Agenda
Agenda Item
9c
Document Relationships
Minutes - 20060613
(Linked To)
Path:
\Board of County Commissioners\Minutes - Approved\2000's\2006
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r`~t ~ ~ ~ ` CARRBORO FIRE DEPARTMENT <br />- <br />CARRBORO, NORTH CAROLINA <br />5 <br />April 4, 2006 <br />To: Mike Tapp, Orange County Fire Marshal <br />From: Travis L. Crabtree, Deputy Fire Chief <br />Carrboro Fire Department <br />I <br />~~ <br />~, ~F yu <br />cy <br />.may ~~ ;,~ ~~ <br />Re: Alternative Water Points for The Orchard Subdivision <br />The fire department requests that an approved water source be <br />provided within l.S miles of the new subdivision proposed to be located <br />at the intersection of Jones Ferry Road and Damascus Church Road. <br />This water source must be certified by a registered professional <br />engineer or soil conservationist that the water source will provide a <br />minimum of 30,000 gallons of usable firefighting water and/or be able <br />to deliver a minimum of 250 gallons of water per minute far no less <br />than a two (2) hour duration during a drought with. an average SO-year <br />frequency. An all weather driving surface capable of supporting the <br />imposed loads of a 40,000 lbs. fire pumper must be provided to ensure <br />year-rouxrd accessibility. <br />The developer should make arrangements to obtain a written statement <br />signed by the owner of any private suction water supply point, <br />authorizing its use by the fire department for emergency firefighting use <br />and at least quarterly maintenance backflushing performed by the fire <br />department along with any water supply training deemed necessary by <br />the fire chief. <br />Additionally, a posted and approved reflective sign shall be erected at <br />the location that is visible in both directions for a minimum of 200 feet. <br />301 West Main Sheet, Carrboro, North Cazolina 27510 Phone (919) 918-7349 Fax (919) 932-5359 <br />An Equal Opportunity Employer <br />
The URL can be used to link to this page
Your browser does not support the video tag.