2017-568-E ES - Eaton Corporation -Service Agreement Addendum to 2016-544-E
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2010's
>
2017
>
2017-568-E ES - Eaton Corporation -Service Agreement Addendum to 2016-544-E
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/25/2018 11:05:25 AM
Creation date
10/17/2017 3:15:40 PM
Metadata
Fields
Template:
Contract
Date
10/17/2017
Contract Starting Date
7/1/2017
Contract Ending Date
6/30/2018
Contract Document Type
Agreement - Services
Amount
$6,454.00
Document Relationships
2014-484 EMS - Eaton UPS Service for power quality equipment for the 911 Center $5,276.50
(Linked To)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2014
2015-437-E EMS - Eaton Corporation - Renewal of UPS Service Agreement for power quality equipment for the 911 Center
(Linked To)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2015
2016-544-E Emergency Svc - Eaton Corporation - UPS Services Contract
(Linked To)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2010's\2016
R 2017-568-E ES - Eaton Corporation - Service Agreement Addendum
(Linked To)
Path:
\Board of County Commissioners\Contracts and Agreements\Contract Routing Sheets\Routing Sheets\2017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID:5A7B2937-A688-4E52-BA63-8DF750C7B5A4 <br /> 111111111111111 111111111r.. <br /> Powering(usurers Vlri�ridW* <br /> Electronics (UPS Power Module, DC, PDU, Flywheel) Preventive <br /> Maintenance <br /> Scope of Work <br /> Attachment R-2 <br /> This scope of work is shared by the following power quality equipment types: Eaton UPS, Eaton <br /> PDU/PDR/RPP/STS, Eaton DC,Vycon Flywheel and Non-Eaton equipment (MVS). Note the <br /> applicable features vary by type of equipment being contracted and additional scopes of work may be <br /> required. <br /> The following is an outline of general checks performed during an Eaton®Preventive Maintenance of the <br /> Eaton UPS Power Module normally performed by Eaton field service personnel. All checks are designed <br /> to be performed during off line operation, in the bypass mode. All checks or processes may not be <br /> applicable to all equipment types or models. <br /> 1. Visual Inspection <br /> a. Inspect all printed circuit board connections for cleanliness, swab contacts if necessary. <br /> b. Inspect all power connections for signs of overheating <br /> c. Inspect all subassemblies, bridges and legs for signs of component defects or stress <br /> d. Inspect all DC capacitors for signs of leakage <br /> e. Inspect all AC capacitors for signs of leakage <br /> f. Inspect and inventory all customer-owned spare parts <br /> g. Inspect for, and perform as required, any open engineering changes <br /> h. If work is completed under a PowerTrustTM Ultra contract, inspect battery monitoring <br /> system <br /> 2. Internal Operating Parameters <br /> a. DC Ground Detection Offset(if applicable) <br /> b. Inverter leg current average balance (if applicable) <br /> c. Output filter current average phase balance <br /> d. Rectifier bridge current average leg balance <br /> e. AC Protection settings are checked <br /> f. DC Protection settings are checked <br /> g. Input and Output Frequency and Voltage Bandwidth settings are checked <br /> h. Verify DC filter capacitance <br /> i. Verify AC tank and trap filter capacitance <br /> j. Power Supply voltages and waveforms <br /> k. Update firmware as necessary with customer approval (parts if required are included at <br /> no charge under service agreements with full parts coverage, otherwise billable) <br /> I. Evaluate Field Service Bulletins (FSBs)for potential updates (parts if required are <br /> included at no charge under service agreements with full parts coverage, otherwise <br /> billable) <br /> 3. External Operating Parameters <br /> a. System Input Voltages (all phases) <br /> b. System Input Currents (all phases) <br /> c. DC Charging Voltages (float and equalize), record settings, adjust to nominal <br /> d. Rectifier phase on and walk up <br /> e. Inverter phase on and walk up <br /> Scope of Work Attachment R-2 <br /> Revision 10/14 <br /> Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.