Browse
Search
Agenda - 03-21-2006-9d2
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2000's
>
2006
>
Agenda - 03-21-2006
>
Agenda - 03-21-2006-9d2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2013 8:46:35 AM
Creation date
8/29/2008 9:17:40 AM
Metadata
Fields
Template:
BOCC
Date
3/21/2006
Document Type
Agenda
Agenda Item
9d2
Document Relationships
Minutes - 20060321
(Linked To)
Path:
\Board of County Commissioners\Minutes - Approved\2000's\2006
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
to <br />Mr. J. Robert Blowe <br />February 17, 2006 <br />Page 2 <br />The permitting responsibility for the grant- excluded portion of the project <br />(school area) will remain with the Construction Loans and Grants Section; <br />Funding eligibility issues (power and control center shelter, landscaping and <br />pavement, all at the middle school pumping station) that have been raised <br />by CGLS staff in the STAG review process are not issues if this portion of <br />the project is broken out of the STAG grant <br />CGLS concerns as to the capacity of Mebane's existing infrastructure will <br />be satisfactorily addressed if Mebane: <br />1) installs a 12" gravity sewer line to replace the entire 1200 linear foot <br />section of existing 8 gravity sewer line between the point where the <br />Industrial Drive pumping station force main currently discharges and <br />Mebane's existing 12" outfall main; <br />2) provides an Engineer's report using DWQ- approved methodology, 3.6 <br />peaking factor', calculations and modeling to demonstrate that <br />a) reducing the flow rate of the LJ Rogers pumping station from 200 <br />to 100 gpm; and <br />b) redirecting the LJ Rogers pumping station flow from the Industrial <br />Drive pumping station to the existing 8" force main at a point <br />between the Industrial Drive pumping station and the existing <br />discharge into Mebane's gravity system; <br />will leave the Industrial Drive pumping station with sufficient pumping <br />capacity to receive the projected flow from the school project and the <br />flow — existing and projected - from the sewer service areas now <br />tributary to pumping station as well as that which will become tributary <br />with the completion of the northern Buckhorn community (that will be <br />coming on line with the completion of the reconfigured STAG project; <br />and <br />3) provides letter with a schedule for submitting plans and specifications for <br />the improvements /modifications outlined in (1) and (2) above <br />CGLS will issue permission for Orange County to proceed with advertisinc <br />the broken out portion of the existing STAG project upon receiving and <br />approving Mebane's infrastructure improvement plans, Orange County's <br />request to reconfigure the STAG project and approving Orange County's <br />construction documents revised to reflect the circumstances of the broken <br />out (school service area) project. <br />
The URL can be used to link to this page
Your browser does not support the video tag.