Orange County NC Website
DocuSign Envelope ID:05BAC521-A573-4502-9361-CAFO7F6BEC40 <br /> TEST DATA the surface for at least 5 seconds before being absorbed. <br /> NCHRP#244(@200 ftz/gal) Coverage rates on horizontal concrete surfaces are typically <br /> Series II 86%reduction in water absorption between 150 and 250 ft2/gal.Coverage rates on vertical <br /> Series II 87%reduction in chloride absorption surfaces depend on the type of material to be treated.Your <br /> Series IV 99%reduction in chloride absorption Protectosil representative can give an exact coverage rate <br /> ASTM C 672"Deicer Scaling" for your particular project.Please refer to the"Protectosil <br /> 100 cycles-0+rating CHEM-TRETE 40 VOC Application Instructions"for more <br /> (non-air-entrained concrete) detailed information. <br /> ASTM E303"Skid Resistance" Precautions:Protectosil CHEM-TRETE 40 VOC is a <br /> Dry surface no change flammable liquid and should be kept away from heat,sparks, <br /> Wet surface no change open flame and other sources of ignition.Protectosil <br /> Alberta DOT Penetrating Sealers Type lb CHEM-TRETE 40 VOC containers should be kept closed <br /> Initial water repellency 84.3% when not in use and should be stored at temperatures <br /> After abrasion 85.1% between 0°F(-18°C)and 120°F(50°C),away from rain and <br /> standing water.When working in an enclosed area,an air <br /> ASTM E 514"Water Permeance of Masonry" respirator should be used.Please refer to the material safety <br /> Untreated leakage 5.51/hr(1.5 gal/hr) data sheet for more detailed information. <br /> Treated leakage 0.01/hr(0.0 gal/hr) <br /> Reduction in leakage 100% AVAILABILITY <br /> ASTM C67 Water Absorption of Brick Protectosil CHEM-TRETE 40 VOC is available in <br /> 24 hours 98%effective 5-gallon pails and 55-gallon drums. Shipped F.O.B. <br /> 5 days 91%effective throughout the United States and Canada. Contact your local <br /> ASTM D 1653 Water Vapor Transmission Protectosil representative or your regional manager for spe- <br /> 75.8 g/ft2/24 hours,100%breathable cific cost information.You can obtain their contact informa- <br /> tion on our website,www.protectosil.com,or by calling us at <br /> INSTALLATION 1(800)828-0919. <br /> Concrete must be allowed to cure for a minimum of 28 days. <br /> All repointing must be completed and allowed to cure for at TECHNICAL SERVICE <br /> least 3 days.Concrete repair and replacement must be Technical service engineers and scientists are available to <br /> completed prior to application of Protectosil CHEM- answer questions about product performance,application <br /> TRETE 40 VOC.Patching materials,caulking,sealing mate- methods and compatibility with other building materials. <br /> rials and traffic paint must be fully cured before applying You can speak to one of our engineers or scientists directly <br /> Protectosil CHEM-TRETE 40 VOC. by calling our toll-free number,1(800)828-0919,and se- <br /> All surfaces must be cleaned to remove all traces of dirt, lecting option 1. <br /> dust,efflorescence,mold,salt,grease,oil,asphalt,laitance, <br /> curing compounds,paint,coatings and other foreign materi- MANUFACTURER <br /> als.Acceptable surface cleaning methods include shotblast- Evonik Corporation <br /> ing,sandblasting,waterblasting,and using chemical clean- 299 Jefferson Road <br /> ers.Check with your Protectosil representative to verify that Parsippany,NJ 07054-0677 <br /> surface preparation is adequate. 1(800)828-0919 <br /> Protectosil CHEM-TRETE 40 VOC should be applied using info.protectosil�a evonik.com <br /> low-pressure(15 to 25 psi)pumping equipment with a wet www.protectosil.com <br /> fan type spray nozzle.Alternate methods include using PROTECTOSIL PRODUCTS ARE MANUFACTURED AF <br /> either a power roller with a 1"nap or a brush.Do not alter or <br /> THE EVONIK CORPORATION TH IEODORE,ALABAMA, <br /> dilute the material.Do not apply to a wet or damp substrate. <br /> A test patch should be applied to the substrate by a PLANT UNDER A QUALITY SYSTEM CERTIFIED TO ISO- <br /> Protectosil representative to verify coverage rate and 9001 AND ISO 14001 REQUIREMENTS. <br /> application conditions. <br /> On vertical surfaces,apply Protectosil CHEM-TRETE <br /> 40 VOC in a flooding application from the bottom up,so the <br /> material runs down 6 to 8 inches below the spray pattern. <br /> On horizontal surfaces,the liquid material should pond on <br /> For more information,MSDS and the most updated product information,and to find your local representative,go to www.protectosil.com <br /> Protectosil®,CHEM-TRETE®=registered trademarks of Evonik Industries <br /> This information and all technical and other advice are based on Evonik Corporation's("Evonik")present knowledge and experience.However,Evonik as- <br /> sumes no liability for such information or advice,including the extent to which such information or advice may relate to third party intellectual property <br /> rights.Evonik reserves the right to make any changes to information or advice at any time,without prior or subsequent notice.EVONIK DISCLAIMS ALL <br /> REPRESENTATIONS AND WARRANTIES,WHETHER EXPRESS OR IMPLIED,AND SHALL HAVE NO LIABILITY FOR MERCHANT ABILITY OF THE <br /> PRODUCT OR ITS FITNESS FOR A PARTICULAR PURPOSE(EVEN IF EVONIK IS AWARE OF SUCH PURPOSE),OR OTHERWISE.EVONIK SHALL NOT <br /> BE RESPONSIBLE FOR CONSEQUENTIAL,INDIRECT OR INCIDENTAL DAMAGES(INCLUDING LOSS OF PROFITS)OF ANY KIND.It is the customer's <br /> sole responsibility and obligation to arrange for inspection and testing of all products by qualified experts.Reference to trade names used by other companies <br /> is neither a recommendation nor an endorsement of the corresponding product,and does not imply that similar products could not be used. <br />