Browse
Search
Agenda - 05-02-2017 - 6-d - Award of Design-Build Agreement – Sportsplex Field House Project
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2010's
>
2017
>
Agenda - 05-02-2017 - Regular Mtg.
>
Agenda - 05-02-2017 - 6-d - Award of Design-Build Agreement – Sportsplex Field House Project
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/27/2017 3:37:59 PM
Creation date
4/27/2017 4:55:49 PM
Metadata
Fields
Template:
BOCC
Date
5/2/2017
Meeting Type
Regular Meeting
Document Type
Agenda
Agenda Item
6d
Document Relationships
Minutes 05-02-2017
(Linked From)
Path:
\Board of County Commissioners\Minutes - Approved\2010's\2017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
62 <br /> SPECIFIC DECISIONS FOR PROPOSED BUILDING PLAN: <br /> 1. Phase one will be approximately 112'X 200' or 22,400 S.F. The building will be a one- <br /> story pre-engineered metal building utilizing a simple saver insulation and interior <br /> ceiling finish system. Heating and cooling will be provided by units hung from the <br /> structure above with exposed duct work for supply locations. Condensers will have to <br /> be located outside the building at multiple locations. <br /> 2. Phase one will include two indoor basketball courts with 12'0"runoff between them. <br /> This will allow enough room for tilt and roll bleachers to be used for some events. <br /> 3. Study high bay lighting through the building for cost effectiveness. <br /> 4. The basketball courts will have a Rexcount like finish surface similar to the two senior <br /> centers. <br /> 5. The area remaining adjacent to the basketball courts will house the following: <br /> a) Main entrance two small reception areas/office area <br /> b) Public toilets (Code-required minimal)No locker rooms will be provided. <br /> c) Nursery <br /> d) Two classrooms with wall dividers to serve as the Kidsplex. <br /> e) Exercise machine area. This area needs to be separated from the rest of the <br /> building since access to this area is open to fitness members only. <br /> f) Phase one will also include an outdoor turf field adjacent to the building with <br /> cost effective field lighting. This field will be enclosed under a future phase of <br /> the project. <br /> g) An ADD ALTERNATE should be considered for the concrete footings for the <br /> future building structure. <br /> II II <br /> cra 222 cloister court l chapel hill, nc 27514 I t: 919.401.8586 <br />