Browse
Search
Agenda - 05-02-1983
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
1980's
>
1983
>
Agenda - 05-02-1983
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/24/2017 9:46:37 AM
Creation date
4/18/2017 2:16:29 PM
Metadata
Fields
Template:
BOCC
Date
5/2/1983
Meeting Type
Regular Meeting
Document Type
Agenda
Document Relationships
Minutes - 19830502
(Linked From)
Path:
\Board of County Commissioners\Minutes - Approved\1980's\1983
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
fs.-4 <br /> rf <br /> • <br /> A.3 <br /> Second Draft ' <br /> Typed 4-20-83 <br /> APPENDIX A (CONTINUED) <br /> Enclosures with tops or roofs shall have sides with a minimum <br /> height of eight (8) feet. Enclosure tops or roofs shall be <br /> constructed of not less than eleven and one-half (Ilk) gauge, <br /> steel chain link fencing which shall be attached securely to <br /> the enclosure sides and/or horizontal, piping or crossbars by <br /> means of steel wire ties spaced at not more than three (3) <br /> inch intervals. <br /> Enclosures without tops or roofs shall have sides with a <br /> minimum height of twelve (12) feet. At the top of the en- <br /> closure sides, there shall be an overhang of four (4) feet <br /> in length, extending inward toward the cage interior, and <br /> forming an angle of forty-five degrees (45°) with the enclo- <br /> sure sides. The overhang shall be constructed of not less <br /> than nine (9) gauge, steel chain link fencing which shall be <br /> attached securely to the enclosure sides and/or horizontal <br /> piping or crossbars by means of steel wire ties spaced not <br /> more than three (3) inches apart. <br /> For purposes of structural integrity, no gaps of larger than <br /> two (2) inches shall be permitted between roof or top and <br /> side fencing, between enclosure poles and entrance gates into <br /> the enclosure, and between side fencing and ground or floor <br /> level. <br /> Every enclosure floor or base shall be constructed of con- <br /> crete or shall be comprised of at least six (6) inches of <br /> crushed stone. Where a concrete floor is provided, fencing <br /> used for enclosure- sides shall be extended into and encased <br /> in the concrete to prevent the animal from tunneling out. <br /> Where a crushed stone base is provided, the side fencing <br /> must be extended thirty (30) inches below the surface of the <br /> ground or secured at ground level by means of a horizontal <br /> crossbar or piping. Where side fencing is secured to a <br />
The URL can be used to link to this page
Your browser does not support the video tag.