, <br /> EFFLUENT PUMPING For maximum corrosion resistance. <br /> EQUIPMENT FOR . the discharge piping, junction box <br /> PRESSURE SEWERS and shutoff valve are made of plastic <br /> materials.Mercury ball level controls <br /> In grinder pump pressure sewer <br /> are standard.Some engineers speci- <br /> systems there has been only one size fy a redundant check valve to be 10- <br /> centrifugal grinder pump (2 hp) avail- cated in service line for added <br /> able for installation at the individual protection. An anti-siphoning valve <br /> home. However, in a STEP pressure is added to the internal piping if low <br /> sewer, the engineer can choose from heads or negative heads (downhill <br /> a variety of horsepowers and sizes. runs) are expected to prevent any <br /> STEP pumps can be 1/3, .4, 1/2, 1, siphoning action. In most cases, the . <br /> 1-1/2 and 2 hp, depending on the cover is made of steel so that it can <br /> head and flow requirements.The per- - . withstand the weight of a riding lawn <br /> formance, weight, and cost of the mower. Pump basin covers are nor- <br /> STEP pumps increase as . horse- many installed flush with the ground <br /> power increases. The STEP pumps level. An anti-flotation flange held <br /> that are available are basically sump by concrete is provided to prevent <br /> pumps, small hp sewage ejectors or the basin from moving upward in <br /> modifications thereof. highwater table areas. <br /> One of the drawbacks of currently . <br /> available STEP pumps is that they • <br /> generate much higher flows than PERFORMANCE <br /> needed. As an example, a 1/2 hp <br /> Since STEP pumps are pumping a <br /> STEP'pump can generate up to 80 <br /> gpm with shut off heads to 78 feet. clarified liquid from a septic tank. <br /> Since the peak wastewater flow there is usually very little problem <br /> generated from an average individual with the pump plugging.The risk of <br /> home is no more than 8-15 gpm, <br /> plugging is greater if an old septic <br /> you <br /> can see that the flow rates are much tank is used which is generating <br /> higher than needed. The high flow ohveearvysoflioidwssdaunedtopoinssfiiibtrlyatsioonm.e carry <br /> rates make it more difficult to hydrau- over solids due to infiltration. <br /> lically design a pressure sewer and t At one time, it was assumed that <br /> will increase pipe sizes. In addition, <br /> the high flow rates of the standard a high percentage of old septic tanks <br /> effluent pumps can create problems could be utilized as part of a STEP <br /> when discharging into a variable pressure sewer.Now,the consensus <br /> gravity sewer system. of opinion is that the majority of old <br /> septic tanks should be replaced <br /> with new ones.One of the problems <br /> Septic tanks can be made of fiber- in using old septic tanks is the ques- <br /> glass,polyethylene or concrete.Con- tion of how do you determine if the <br /> Crete is the most readily available, tank is leaking. By the time you <br /> The most common size used is 1000 . pump out the septic tanks, find the <br /> gallons,although 500 and 750 gallon leak and repair it (assuming this can <br /> size tanks have been used in some be accomplished), it may be less <br /> pressure systems. In commercial expensive to put in a new septic tank. <br /> applications, larger size septic tanks <br /> will be required. Two potential problems associated <br /> with STEP systems are corrosion <br /> Variations of an audio and visual and odors.'AS previously indicated, <br /> alarms are used, although the most . . corrosion can be overcome by <br /> popular and cost-effective is a red _ choice of materials.Since the septic <br /> flashing alarm light mounted on con- tank is vented through the house <br /> trol panel. Most all control panels plumbing system,no outside venting <br /> with a disconnect switch are located is required. Care must be taken to <br /> outside so they will be easily acces- . insure the cover to the wet well is <br /> sible to the serviceman. The prefer- sealed properly. Odors can be a <br /> able location of the panel and alarm problem at intermediate pump sta- <br /> is on the side of the home or garage tions if vented to atmosphere. This <br /> to minimize aesthetic concerns of can be solved by installing an under- <br /> the home owner. If desired, the ground venting system. <br /> panel can be located at the septic • <br /> tank/pump basin and mounted on a . <br /> pedestal. <br /> ....._...._.__;. 3 <br /> CRAIG S.MORGAN AND ASSOCIATES,R:A....----," <br /> 1:1232=5=11.11, <br />