Browse
Search
Agenda - 01-04-1993 - III-C
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
1990's
>
1993
>
Agenda - 01-04-1993
>
Agenda - 01-04-1993 - III-C
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2017 3:22:56 PM
Creation date
1/3/2017 8:41:20 AM
Metadata
Fields
Template:
BOCC
Date
1/4/1993
Meeting Type
Regular Meeting
Document Type
Agenda
Agenda Item
III-C
Document Relationships
Minutes - 19930104
(Linked From)
Path:
\Board of County Commissioners\Minutes - Approved\1990's\1993
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FINKBEINER, PETTIS & STROUT, LIMITED p <br /> � G 39 <br /> • <br /> CONSULTING ENGINEERS <br /> ESTABLISHED 1900 <br /> )NE CENTERVIEW DRIVE October 10, 1990 - <br /> GREENSBORO,NC Z-407 <br /> ,1q-292-2271 <br /> 419-x53-S64m FAX <br /> Mr. Phillip Whitaker <br /> Manager, Town of Hillsborough <br /> P .O. Box 429 <br /> Hillsborough, NC 27278 <br /> Re: Hillsborough, North Carolina <br /> Whitted Forest Plan Review <br /> ][71-1MS Dear Mr. Whitaker: <br /> We have received a proposed site plan for the Whitted Forest <br /> development on US 70 at Holiday Park Road and have conducted a <br /> preliminary review of its water•, sewer and stormwater aspects . <br /> The following comments summarize our review: <br /> 1) Although proposed stormwater improvements are shown on <br /> the plans, supporting calculations for pipe sizing, <br /> runoff volume, etc. must be submitted before we can <br /> evaluate their compliance with Town standards. <br /> 2) All sewers operated and maintained by the Town of <br /> Hillsborough must be a minimum of 8-inch diameter and <br /> have manholes at a 400 foot maximum spacing. Easements <br /> (20 feet wide) must be dedicated for this purpose. If <br /> the Town does not operate and maintain the sewers, the <br /> developer can install the system of his choice with the <br /> understanding that all sewers within public right-of-way <br /> must conform to the standards described above. <br /> 3) All water main sizes must be shown on the plans . <br /> 4) The developer should be informed that a 12-inch water <br /> main is planned for Holiday Park Road and, should be <br /> considered during design. <br /> 4) Reference is made to two letters dated May 26, 1987 and <br /> May 29, 1987 (attached) regarding utility service to <br /> this same property. The recommendations in those <br /> letters remain valid. <br />
The URL can be used to link to this page
Your browser does not support the video tag.