Orange County NC Website
004 1(-■ <br /> The Planning Staff finds that there is a preponderance of evidence to indicate <br /> substantial compliance with the General Standards and specific rules governing <br /> the Planned Development-Office-Institutional, Class A Special Use Permit. The <br /> Planning Staff recommends approval of the request, with the following imposed <br /> conditions: <br /> 1. That sanitary sewer exist to the proposed site or be constructed as <br /> part of this development propoSal. <br /> 2. That a plat showing the dedication of 15' additional-right of way <br /> on N.C. 86 and 10' of additional right of way on Homestead Road (SR <br /> 1777), and a 35' wide landscape buffer from the new right of way <br /> line, and any necessary sanitary sewer or drainage easements be <br /> recorded prior to the start of any construction. <br /> 3. That all structures presently existing on the site shall be removed <br /> at the time that they are no longer inhabited by the present occupants. <br /> 4. That all signs for the development shall be according to Section 7. <br /> 16.7 and Article 9 of the Zoning Ordinance, <br /> 5. Drainage, soil erosion and sedimentation plans shall be reviewed <br /> and approved by Orange County. The installation of control devices <br /> and on going construction work shall be inspected by Orange County. <br /> The site shall at all times be in conformance with the Soil Erosion <br /> and Sedimentation Control Ordinance. <br /> 6. Tnat both driveway access points on Homestead Road be located to <br /> achieve a sight distance of 462' each way for each driveway. That <br /> plans for these relocated driveways including topography contours <br /> across the roadway or a profile of the roadway be sutmitted to <br /> the Town Manager of Chapel Hill for his approval prior to the start <br /> of construction. <br /> 7. That all parking and storage areas with the exception of those to <br /> be used for heavy equipment parkdng and equipment storage, be paved <br /> to the standards contained in the Chapel Hill design and construction <br /> manual. <br /> 8. That the proposed dumpster be placed on a 10' x 20' concrete pad <br /> 6" thick with wire mesh, <br /> 9. That the proposed pedestrian access to NC 86 be relocated to end <br /> at the intersection of Homestead Road and NC 86. <br /> 10. That left turn lanes and right turn deceleration lanes be constructed <br /> to the Town of Chapel Hill Standards, at both proposed entracnes to <br /> the project on Homestead Road. These improtements shall be completed <br /> prior to the issuance of the Certificate of Occupancy. <br /> 11. If a fire hydrant does not exist within 500' of the building, one <br /> should be installed at the intersection of Homestead Road and NC 86 <br /> and one should be installed adjacent to the service entrance on Home- <br /> stead Road. <br /> 21 <br />