Orange County NC Website
DocuSign Envelope ID:A9CF8A9E-4CDB-4BB9-A678-D4AD80CD1393 <br /> 5thWall Building Diagnostics Consultants Roof Replacement <br /> Central Recreation Center <br /> Hillsborough,NC <br /> August 2016 <br /> 3.08 Cleaning up <br /> A. Remove masking tape immediately after joints have been tooled. <br /> B. Keep adjacent surfaces clean and free from sealant as the installation progresses. Use <br /> solvent or cleaning agent as recommended by the sealant manufacturer. <br /> C. Do not allow uncured sealants to contact surfaces adjacent to the joints, or any other non- <br /> joint surfaces. If uncured sealants are introduced to prohibited areas, sealant shall be <br /> removed as follows: <br /> 1. Non-porous Surfaces - Immediately remove all excess sealant adjacent to the <br /> joint and elsewhere by using xylol,tolvol or methyl ethel ketone while sealant is <br /> still in uncured state. <br /> 2. Porous Surfaces - Allow sealant to develop initial cure, then remove by abrasion <br /> or other mechanical means. Exercise extreme care to maintain the original <br /> surface texture without damage. <br /> END OF SECTION <br /> 16-171 Sealants and Caulking <br /> 079200-5 <br />