Orange County NC Website
DocuSign Envelope ID:A9CF8A9E-4CDB-4BB9-A678-D4AD80CD1393 <br /> 5thWall Building Diagnostics Consultants Roof Replacement <br /> Central Recreation Center <br /> Hillsborough,NC <br /> August 2016 <br /> B. Gaps greater than 1/8 inch shall be filled by cutting out enough material to allow <br /> placement of a minimum 3-inch wide piece of similar insulation. Fill gaps smaller than <br /> 1/4 with insulation adhesive. <br /> C. Board-to-board height variations greater than 1/8 inch at top surface on insulation shall <br /> be shaved to provide a smooth transition. <br /> D. At all perimeters, interior and exterior, insulation shall be fitted in such a manner as to <br /> allow pieces no smaller than 18 inches in width. <br /> E. Tapered edge strip shall be installed around drains to four a 4 ft. X 4 ft. sump with the <br /> drain at the center. <br /> F. Insulation shall be terminated immediately adjacent to roof penetrations. <br /> END OF SECTION <br /> 16-171 Board Insulation <br /> 072120-6 <br />