Orange County NC Website
DocuSign Envelope ID:A9CF8A9E-4CDB-4BB9-A678-D4AD80CD1393 <br /> 5thWall Building Diagnostics Consultants Roof Replacement <br /> Central Recreation Center <br /> Hillsborough,NC <br /> August 2016 <br /> DIVISION 6 <br /> WOOD,PLASTICS AND COMPOSITES <br /> SECTION 061000 <br /> ROUGH CARPENTRY <br /> PART 1 GENERAL <br /> 1.01 Related Documents <br /> Drawings and general provisions of the contract including General, Supplemental and Special <br /> Conditions,and other Division 1 specification sections apply to work of this section. <br /> 1.02 Work Included <br /> A. Installation of new treated wood nailers at roof perimeters where required. <br /> B. Installation of new treated wood nailers at rooftop equipment bases and support curbs. <br /> C. Installation of new wood blocking, cants, etc. where required. <br /> D. Replacement of damaged or deteriorated wood nailers and blocking. <br /> 1.03 Related Work <br /> A. Section 024119—Selective Demolition <br /> B. Section 035010—Gypsum Roof Deck Repair <br /> C. Section 075120—Board Insulation <br /> D. Section 075217—Polymer Modified Bituminous Membrane Roofmg(Cold Applied) <br /> E. Section 076200—Sheet Metal Flashing and Trim <br /> 1.04 Environmental Conditions <br /> Material installation shall proceed only when weather conditions are in compliance with the <br /> manufacturer's recommendations for installation and no precipitation is imminent. Materials <br /> installed during adverse weather conditions shall be subject to rejection including removal and <br /> replacement. <br /> 1.05 Quality Assurance <br /> A. Provide sufficient qualified workmen and supervisors who shall be present at all times <br /> during execution of this portion of the work and who shall be familiar with the type of <br /> construction involved and the materials and techniques specified. <br /> B. The Owner shall make no allowance for lack of skill of the workmen. <br /> 1.06 Submittals <br /> A. Product Data: For each type of process and factory-fabricated product. Indicate <br /> component materials and dimensions and include construction and application details. <br /> B. Structural Composite Lumber: Submit manufacturer's published structural data including <br /> span tables, marked to indicate which sizes and grades are being used; if structural <br /> composite lumber is being substituted for dimension lumber or timbers, submit grading <br /> agency structural tables marked for comparison. <br /> 16-171 Rough Carpentry <br /> 061000-1 <br />