Orange County NC Website
DocuSign Envelope ID:A9CF8A9E-4CDB-4BB9-A678-D4AD80CD1393 <br /> 5thWall Building Diagnostics Consultants Roof Replacement <br /> Central Recreation Center <br /> Hillsborough,NC <br /> August 2016 <br /> 2. When the manufacturer or the manufacturer's approved applicator fails to <br /> perform repairs within 72 hours of notification, emergency repairs performed by <br /> others will not void the warranty. <br /> F. With regard to the repair of leaks under the terms of the manufacturer's No Dollar Limit <br /> warranty, the manufacturer shall replace insulation which has been damaged by leakage <br /> when that insulation contains detrimental amounts of moisture. <br /> G. In addition, should the roof system experience recurring leaks (more than two in a given <br /> section of the roof system) over a period of 12 consecutive months, the building Owner <br /> may request an inspection of that portion of the roofing system experiencing recurring <br /> leaks by the manufacturer or the Owner's designated representative. The contractor shall <br /> then follow the recommendations of the inspector as to appropriate resolution of the <br /> problem. <br /> H. Final payment will be made to the Contractor only after three signed and notarized copies <br /> of the warranties and guarantees have been submitted and the membrane manufacturer <br /> acknowledges that all bills are paid. All such documents shall show the project name, <br /> project number, and location and the Owner's name. <br /> I. All new materials and workmanship covering work provided under Section 076200 Sheet <br /> Metal Flashing and Trim shall be guaranteed in writing by the Contractor to be in a <br /> watertight condition for a period of five years after date of final payment. <br /> J. The effective date of all warranties shall be the same and shall be on the date of the last <br /> final inspection when the Owner, Designer, Contractor and Manufacturer agree that all <br /> work has been completed in substantial compliance with the plans and specifications. <br /> K. Contractor shall post 8 1/2" X 11" signs provided by the Owner on the building in <br /> locations as directed by the Owner identifying components of the roof system,the date of <br /> project final completion, the duration of the warranty and standard information and <br /> limitations of warranty provided. <br /> PART 2 PRODUCTS <br /> Not Used <br /> PART 3 EXECUTION <br /> Not Used <br /> END OF SECTION <br /> 16-171 Warranties <br /> 017850.3 <br />