Browse
Search
Agenda - 11-23-1987
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
1980's
>
1987
>
Agenda - 11-23-1987
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/20/2016 2:07:24 PM
Creation date
10/4/2016 4:21:00 PM
Metadata
Fields
Template:
BOCC
Date
11/23/1987
Meeting Type
Regular Meeting
Document Type
Agenda
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
265
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
132 <br /> Recommended Design Criteria for Septic Tank Effluent Pumps (Cont.) <br /> Page 2 . . 116 <br /> + E. Control panel must be mounted on the side of the house nearest the pump <br /> + tank and readily accessible. <br /> 1 . Panel must be in a NEMA 4X, vandal -resistant enclosure. <br /> 2. Panel must be U.L. listed and include a pump run light and hand-off- <br /> automatic (H-O-A) switch. . <br /> • • 3. An audible and visible high-water alarm must be provided. The visible <br /> d alarm must be visible from the road. The audible alarm must be audible <br /> • inside the house and may be located in the house. <br /> 4. Two separate circuits must be supplied from- the main house electrical <br /> panel--one circuit for the pumps and pump controls and one circuit for <br /> the high-water alarm. <br /> F. Service laterals must be of Schedule 40 PVC, or stronger material , and <br /> • must include a check valve and gate valve within a valve box adjacent to the <br /> property line, prior to connecting into the force main. <br /> I. <br /> G. Force main must include a cleanout at the end and at least every 500 feet. • <br /> *. Air re ease valves must be provided at any high spots along the line. <br /> • H. Surge storage tank must be provided in front of the final common dosing tank <br /> with liquid capacity of at least 10 percent the total required septic tank <br /> capacity for the project as a whole to give further solids retention in case <br /> of upset at one or more of the individual lift stations. <br /> I . Legal Arrangements/Ooeration'and Maintenance'Requirements <br /> 1 . Developer or owners association must be responsible for installing the <br /> individual lift stations and for continuous station maintenance. They <br /> 4 • must retain easements permitting access and maintenance to each lift <br /> station and to the electrical controls. <br /> iO 2. Developer or owners association must retain a licensed wastewater treat- <br /> ment plant operator to be responsible for operation and maintenance of <br /> the entire system, including individual lift stations and maintenance <br /> 00 of individual septic tanks. <br /> 00 3. An inventory of at least 10 percent of the active pumps, level control <br /> floats, and complete control panels must be maintained by the developer <br /> 00 or owners association and readily available to the system operator. <br /> 00 4. The tri-party agreement among the developer, owners association, and <br /> health department must clearly indicate ownership, operation and main- <br /> * tenance requirements for the individual lift stations. <br /> 4 <br /> SB/gb <br /> 00 Nov. , 1986 <br /> I <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.