Browse
Search
Agenda - 08-24-1987
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
1980's
>
1987
>
Agenda - 08-24-1987
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2016 8:31:32 AM
Creation date
10/4/2016 12:11:06 PM
Metadata
Fields
Template:
BOCC
Date
8/24/1987
Meeting Type
Public Hearing
Document Type
Agenda
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
289
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. L. Harding Hughes, Jr. 07 8 <br /> June 23, 1987 <br /> Page Two <br /> B. Min. 1500 GPM @ 20 psi residual fire fighting demand. <br /> 2. All water lines shall be DIP class 50. <br /> 3. All sewer lines shall be extra strength vitrified clay pipe, or DIP where <br /> conditions require such. DIP shall be cement mortar lined. <br /> 4. See Item 1 concerning water and sewer demands, all based on the Master <br /> Development Plan. The gravity sewers will be capable of handling these <br /> anticipated flows. <br /> 5. All utility easements shall be min. 20-foot in order to conform Town <br /> standards, as revised on drawings. <br /> 6. Conditions prevent an 18-inch vertical separation between the 6-inch DIP <br /> water line stub at STA 27+60 over the 8-inch DIP gravity sanitary sewer, <br /> while maintaining a 36-inch cover over the water line. Such an ; <br /> installation is acceptable in accordance with. the Rules Governing Public <br /> Water Supplies, NC Administrative Code, Subchapter 10D-Water Supplies, <br /> NCDHS, Section .2106(6), copy attached. <br /> 7. All individual sewer service lines shall enter the main line atwyes as <br /> revised on the drawings. <br /> 8. The correct slope between manholes C and D is corrected to be 0.50%, and <br /> is redrawn correctly. <br /> 9. The profile between manholes G and H is correctly redrawn to shw the 1.0% <br /> slope. d <br /> 10. The drawings have been revised to show the location of Manhole A only, to <br /> be installed later by others. The lines leading to this manhole will be <br /> installed as indicated and marked to identify the correct locations and <br /> elevations. <br /> 11. The sewer line between manholes C and C--3 is designed at the .de,3ignated <br /> depth (C-3 invert el. 648.31) in order to provide positive gravity <br /> atser ce <br /> to Lot P with a minimum floor elevation of approximately el. 6 <br /> feet away. <br /> { <br />
The URL can be used to link to this page
Your browser does not support the video tag.