Orange County NC Website
DocuSign Envelope ID:90E3EAFE-4412-496F-B485-61 C37DFF7A03 <br /> OODD1i' � <br /> 1111 6 <br /> PowennQQ Business Worldwide <br /> Eaton UPS Flex Onsite Service Parts and Labor Coverage <br /> Scope of Work <br /> Attachment R-30 <br /> This scope of work is shared by the power quality equipment types listed in the below table. Note the <br /> applicable features vary by type of equipment being contracted and additional scopes of work may be <br /> required. All checks or processes may not be applicable to all equipment types or models. <br /> Equipment Type Electronics Corrective Battery Corrective Tech <br /> Maintenance Coverage Maintenance Coverage Support <br /> Eaton 3 Phase UPS Yes No Yes <br /> Eaton 1 Phase UPS Yes Yes Yes <br /> Eaton DC Yes No Yes <br /> Eaton PDU/PDR/RPP/STS Yes No Yes <br /> Flywheel Yes No Yes <br /> Non Eaton equipment(MVS) Yes No Yes <br /> If optionally purchased by Customer within the first three (3)years of a Eaton" 3 Phase UPS installation <br /> date (first startup) OR, <br /> If optionally purchased by Customer in conjunction with one or more annual on-site UPS Power Module <br /> Preventive Maintenance SOW R-2 of the same duration, Contractor will provide: <br /> 1. Electronics Corrective Maintenance Coverage: Inspection and repair of the electronic portion <br /> of the UPS (or other equipment type), or"Power Module" shall be performed as needed during <br /> the contracted period of maintenance at no extra charge to Purchaser. Remedial maintenance <br /> provided by Contractor shall include, and be expressly limited to, maintenance to the Power <br /> Module, travel expenses, all necessary parts replacement, adjustments and repairs. If the <br /> Purchaser maintains Eaton spare parts at the maintenance site, Contractor may, at its option, use <br /> those spare parts in the performance of Corrective Maintenance and shall replace the spare <br /> pads, which it so uses, at no cost to the Purchaser. Exclusions: certain wear parts are excluded <br /> from electronics corrective coverage including batteries and full capacitor replacement. All <br /> Corrective Maintenance to Battery System, if any, will be in accordance with battery <br /> manufacturers' warranty or separate agreement, if any. For Flywheel coverage: any failure due <br /> to lack of recommended bearing replacement, vacuum pump replacement(or"major <br /> maintenance" per manufacturer recommendation)will not be included under corrective <br /> maintenance coverage and will be billable at current time and material rates. Eaton 93PM, 9390 <br /> and 9395 UPS models have a special policy on capacitor replacements: DC link capacitors are <br /> eligible for inspection and repair at no extra charge (excludes AC capacitors). <br /> Scope of Work Attachment R-30 <br /> Revision 12/12 <br /> Page 1 of 2 <br />