Browse
Search
Agenda - 09-02-1986
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
1980's
>
1986
>
Agenda - 09-02-1986
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2016 10:10:26 AM
Creation date
9/26/2016 12:22:23 PM
Metadata
Fields
Template:
BOCC
Date
9/2/1986
Meeting Type
Regular Meeting
Document Type
Agenda
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> ERS, Inc. April 7, 1986 Page 2 05 <br /> 1 • <br /> suitable soil properties 'for low pressure pipe systems. An of <br /> the lots evaluated will require that the nitrification lines be <br /> placed at a depth of less than 36 inches due to the moderate soil <br /> depth to rock or saprol ite. Placement of the nitrification field <br /> piping at a depth of. approximately 18 inches from the soil <br /> surface will take advantage of the loamy textures generally <br /> encountered at this depth at the site. Since most of th <br /> nitrification fields are located up slope from the proposed <br /> dwellings, these systems will require a pump and pump tank in <br /> addition to the septic tank and nitrification field piping. Due - <br /> to the shallow placement and the pump requirements, low pressure <br /> pipe systems are the type of on—site system Law Engineering <br /> recommends for the project. <br /> In addition, we recommend the use of water conservation toilets <br /> at each _ proposed home—site. These toilets substantially reduce - _ <br /> the amount of water to be treated by the system. The toilets <br /> generally work using a small air compressor and usually flush <br /> approximately one gallon of water per flush cycle. Conventional <br /> toilets flush about five gallons of water per cycle. <br /> We appreciate the opportunity to provide these services for your <br /> project. If you have questions or if we can be of further <br /> assistance, please contact us. <br /> • <br /> Very truly yours, . <br /> LAW ENGINEERING TESTING COMPANY - <br /> Fred D. Smith . • <br /> Soil Scientist <br /> lan Tice, P. E. - : '- -• <br /> Senior Geotechnical Engineer <br /> •;- <br /> Registered, North Carolina .6428 •' <br /> •FDS/JAT/sar ; i t <br /> • <br /> • <br /> _.. .«,_ _ ._._..__. .�.. .._..... ......« .�.---•.�...._.....�.....�� ---- .W.� .w..,.�.._...,�...-_.._._. _ Raw gMery=_e++inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.