Orange County NC Website
DocuSign Envelope ID: 989208A2-AC78-4885-B25B-F162607F73BE <br /> Enclosure and Subbase Fuel Tank Specifications (continued) <br /> Sound <br /> Enclosure and Subbase Fuel Tank Pressure at <br /> Est.Fuel 60 Hz with <br /> Supply Hours Max.Dimensions,mm(in.) Max.Weight,kg(Ib.)* Full Load at <br /> Fuel Tank at 60 Hz with Fuel Tank 7 m(23 ft.), <br /> Capacity, Full Load, With Steel With Aluminum Height, Weather/ <br /> L(gal.) Nominal/Actual 1 Length Width Height Enclosure Enclosure I mm(in.) I Sound dB(A) <br /> t80REOZJF <br /> No Tank 0 2057 (81) 1928 (4250) 1780 (3925) 0 (0) <br /> 1514(400) 24/29 4094 (1(31.2) 1338 (52.7) 2540(100) 2861 (6307)* 2713 (5981)* 483 (19) 87172 <br /> 2869(758) 48/55 2946(116) 3255 (7176)* 3107 (6850)* 889 (35) <br /> I80REOZJF with State Code Fuel Tank's <br /> 1556(416) 24130 2585(102) 3162 (6971)* 3014 (6646)* 457 (18) <br /> 5008 (197.2) 1338 (52.7J 87172 <br /> 2896(765) 48/56 2890{114) 3488 (7690}* 3340 (7363)* 762 (30) <br /> 18OREOZJG <br /> No Tank 0 2057 (81) 1928 (4250) 1780 (3925) 0 (0) <br /> 1514(400) 24/31 4094 (161.2) 1338 (52.7) 2540(100) 2861 (6307)* 2713 (5981)* 483(19) 85/72 <br /> 2869(758) 48/58 2946(116) 3255 (7176)* 3107 (6850)* 889 (35) <br /> 18OREOZJGa with State Code Fuel Tankt <br /> 1556(416) 24/32 2585(102) 3162 (6971)* 3014 (6646)* 457 (18) <br /> 2896(765) 48/59 5008 (197.2) 1338 {52.7) 2890 (114) 3488 (7690)* 3340 (7363)* 762 (30) 85/72 <br /> 20OREOZJF <br /> No Tank 0 2057 (81) 2309 (5090) 2161 (4764) 0 (0) <br /> 1514(400) 24/26 4094 (161.2) 1338 (52.7) 2540(100) 3242 (7147)* 3094 (6821)* 483 (19) 87/75 <br /> 2869(758) 48/49 2946 (116) 3636 (8016)* 3488 (7690)* 889 (35) <br /> 20OREOZJF with State Code Fuel Tankt <br /> 1575(416) 24127 2585(102) 3543 (7811)* 3395 (7485)* 457 (18) <br /> 1500 6 (197.2} 1338 (52.7) 87/75 <br /> 2896(765) 48150 2890(114) 4050 (8930)* 3721 (8203)* 762 (30) <br /> 230REOZJE <br /> No Tank 0 2157 (84.9) 2654 (5850) 2540 (5600) 0 (0} <br /> 1767(472) 24129 4121 (162.3) 1338 (52.7) 2659(104.7) 3561 (7850)* 3447 (7600)* 762 (30) 87/75 <br /> 23OREOZJE with State Code Fuel Tankt <br /> 2101 (555) 1 24/34 5009 (197.2) 1 1 2792(109.9) 3895 (8587)* 3782 (8337)* 635 (25) <br /> 3573 944 48158 5325 203.7 338 (52.7} 3071 120.9 4504 (9930)* 4391 (9680)* 914 36 87/75 <br /> 25OREOZJE <br /> No Tank 0 2157 (84.9) 2699 (5950) 2585 (5700) 0 (0) <br /> 1787{472) 24126 4121 (162.3) 1338 (52.7) 2659(104.7) 3606 (7950)* 3493 (7700)* 762 (30) 89/75 <br /> 25OREOZJE with State Code Fuel Tankt <br /> 2101 (555) 1 24131 5009 (197.2) 1 1 2792(109.9) 3940 (8687)* 3827 (8437)* 635 (25) <br /> 3573 944 48/53 5325 209.7 338 (52.7) 3071 120.9 4550 (10030)- 1 4436 (9780)- 914 36 89175 <br /> 275REOZJE <br /> No Tank 0 2157 (84.9) 2835 (6250) 2722 (6000) 0 (0) <br /> 1787(472) 24124 4121 (162.3) 1338 (52.7) 2659(104.7) 3742 (8250)* 3629 (8000)* 762 (30) 89/75 <br /> 275REOZJE with State Code Fuel Tankt <br /> 2101 (555) 24128 5009 (197.2) 2792(109.9) 4076 (8987)* 3963 (8737)* 635 (25) <br /> 3573 944 48148 5325 209.7 1338 (52.7] 3071 120.9 4686 (10330)* 4572 (10080)* 914 36 89175 <br /> Note: Data in table is for reference only,refer to the respective ADV drawings for details, <br /> Note: Refer to TIB-114 for generator set sound data. <br /> * Max.weight includes the generator set(wet)using the largest alternator option,enclosure with acoustic insulation added,silencer,and tank(no fuel). <br /> t State code fuel tank specifications(height and weight)include I-beam option. <br /> G6-99 5/14aa Page 8 <br />