Browse
Search
Agenda - 05-16-1978
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
1970's
>
1978
>
Agenda - 05-16-1978
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2015 3:06:35 PM
Creation date
7/10/2015 3:05:52 PM
Metadata
Fields
Template:
BOCC
Date
5/16/1978
Meeting Type
Work Session
Document Type
Agenda
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- F17 <br /> M. RAY HARDEN, JR. P.E. <br /> CONSULTING ENGINEER <br /> x5946 CHAPEL.HILL HLVM OFFICE;4094265 <br /> DURHAM, NOR'r"CAROLIN 27707 MOMM.4E"Sla <br /> May 3, 1978 <br /> Mr. Sam Gatt�s <br /> Business Manger <br /> Orange County <br /> Hillsborough; North Carolina 2727$ <br /> Re: Northside Community Center <br /> Chapel Hill , North Carolina <br /> ENGINEERING REPORT <br /> The purpose of this report as directed by Mr. Sam Gattis, Orange County <br /> Business Manger, is to inspect the above building and give estimated prices <br /> for renovation. Estimated prices were obtained by bon a fide contractors in <br /> each trade. <br /> 1 . The building appears to be sound structurally with masonry walls, wood <br /> framing floor and roof. <br /> 2. The electrical system needs complete renovation because of overloaded <br /> circuit and inadequate lighting. Also appliances in the retired area <br /> and den �al area are overloading main circuits. <br /> 3. The plumbing is generally in fair shape except all water closets are old <br /> model built without seats, Some W.C. 's need to be removed. The building <br /> manager mentioned the need for additional children's toilets near the <br /> kindergarten. <br /> 4. The hea ing problem is caused by the fact that there is no ceiling <br /> insulation and windows have broken glass as well as loose fitting. <br /> There is also a need for storm windows and weatherstripping. <br /> 5. The ceiling the consists of 2' x 41 the nailed to runners on the <br /> underside of ceiling joists. There is evidence of leaking on tiles. <br /> 6. The shingles on the roof must be replaced to cure roof leaks. <br /> 7. The rain ater gutters and down-spouts need replacing as well as the <br /> facia bo rd. <br /> K One doub Ile set of 3' x 7' doors needs to be replaced, with dour closers <br /> and closers need to be installed on the other set. — <br /> 9. Replace 11lumbing drain from dental laboratory area. _ <br /> 10. Ventilating fans should be installed in the two large openings into the <br /> attic space. <br /> 11 . The exis Ing boiler is leaking badly. It should be inspected <br /> and/or replaced, <br />
The URL can be used to link to this page
Your browser does not support the video tag.