AGENDA ATTACMENL I I I <br /> J A M E S M . W rZ B R , A . i . A . - A . 1 . P . <br /> A p C H 1 T E C T & P L A N N E R <br /> h5EMBER AMERICAN INSTITUTE OF ARCHITECTS AND AMERICAN INSTITUTE of MANNERS <br /> 201 EAST ROSEMARY 5T. <br /> September 26, 1977 CHAPEL HILL, N. C. 2751A <br /> T E L E P H 0 N E 9 2 9 5 3 8 5 <br /> Mr S. M. Gattis <br /> Orange County Manager Re: Project No. IBC-MH-36 <br /> Hillsborough, N. C. 27278 Center for orange-Person-Chatham <br /> Mental Health Program, Chapel Hill, N. <br /> Dear Mr Gattis: <br /> This letter. is written to recommend for consideration by yofun d t e County as <br /> Commissioner's at your earliest convenience of approval <br /> r . t ,.ands not included under bid as Alternate G-3 <br /> Chan�,e Order �'o. � of the replacement sash, previously the General Contract <br /> but, because of insuffi,cien > <br /> recently let to Triad, General. Contractor, for construction of the pPC Mental <br /> Health Center. <br /> As you may recall the County Commissioners during the early stages of Design <br /> Development expressed a strong interest in considering all. possible energy <br /> saving measures. As a consequence l was instructed to have ouro consulting <br /> be <br /> in- <br /> mechanical engineers evaluate all practicable measures that might <br /> echanical into this building. of these measures turn of the most important <br /> corporated involved the treatment of the exterior window areas. <br /> The existin; windows are single glazed commercial type steel sash, all of <br /> which have had the glass broken out of them. The present contract calls for <br /> re,�glazi.ng these with single pane glass and making whatever repairs may be <br /> necessary for proper operation. Only single pane glazing p <br /> since insulating glass would be too thick to fit the old frames. However, <br /> "Cool Shade" screens to deflect the <br /> rec a bleuenergyrsavinghfor summeracool- <br /> been, provided, thus effecting pp <br /> ing loads. The design. capacity of the cooling system is based an this re- <br /> duced load. However, this does noCNin , for n spiteio€ winter cold <br /> have and <br /> consequent meat loss. The heating system, in spite <br /> sufficient capacity to heat the building adquately with the old windows <br /> since it' i.s essentially the original heating system, improved and re-used. <br /> The proposed change order provides for the removal of all the. old steel. <br /> sash and the installation of high quality insulating aluminum sash. Not <br /> only the glazing of insulating glass (tiro thicknesses with air space ial construction <br /> between) but also the frames in contrast t to spe exist sting steel sash which <br /> an efective thermal barrier o osed windows not only <br /> do not provide such a barrier. Thus, these pr' P <br />